EnergyWise
Business Wi-Fi Switch Applications Guide
®
EnergyWise Business is available to customers of Duke Energy Carolinas and Duke Energy Progress. EnergyWise Business
Description
HVAC
Water Heater
Pool Pump
Refrigeration
HVAC
For HVACs only: EnergyWise Business Wi-Fi switch is typically installed
outside near the compressor. It is wired to the same power source as the
compressor. Relays inside EnergyWise Business Wi-Fi switch will intelligently
reduce the compressor run time during a conservation period to reduce the
demand on the electrical grid during conservation periods. Relay(s) inside
the device will interrupt the control signal from the thermostat to the
compressor and will only disable the compressor periodically during a
conservation period. The indoor fan will continue to run during this time.
The indoor temperature is expected to rise a few degrees during the
conservation period, depending on the amount of insulation in the premises.
LEDs and What They Indicate
EnergyWise
Business Wi-Fi switch contains up to four LEDs (light emitting diodes) underneath a clear window in front of
®
the unit. These LEDs show the operation of the EnergyWise Business Wi-Fi switch as shown below:
Shows status of
communication link
Light on when a
conservation period is
active and relay is open
EnergyWise
Business Wi-Fi Switch User Manual
®
Wi-Fi switch can be installed to control the following loads.
It requires connection to line power and must be installed by a
trained, experienced technician.
Yes
circumstances open the door and touch any components inside as
line voltage (120 – 240 VAC) is present. They should be aware
Yes
they could damage this product or cause a hazardous condition if
Yes
they fail to follow these instructions.
Need Help? For assistance with this product please visit call
Yes
866.821.8423.
Link
Test
Relay 1
Relay 2
LED Indicators
Customers should not under any
Used by installer
Light on when a
conservation period is
active and relay is open
2

Advertisement