Battery replacement
When the touch screen batteries are low, the touch screen will
display the red battery icon on the Home and Settings screens.
1.
Remove the touch screen from the mounting plate by
inserting a small screwdriver into the slot on the bottom of
the touch screen.
2.
Replace all batteries being sure to follow the polarity
instructions (see Specifications for recommended batteries).
Avoid touching the touch screen face while you are replacing
the batteries.
3.
Briefly disconnect the AC power (this will clear the battery
fault).
4.
Reconnect AC power.
Note:
If AC power is lost and batteries are not present or are
depleted, the touch screen will not power up until AC power is
restored (even if new batteries are installed).
Reset button
The Reset button is located on the bottom left side of the touch
screen mounting plate (see Figure 1 on page 2). To power cycle
the touch screen, use a toothpick to depress the recessed Reset
button.
Note:
Do not press the Reset button while in programming mode.
Clear operation
If the Simon XT panel is connected to an online service, some
information (such as a dealer logo) can be stored in the touch
screen memory. To erase touch screen memory and restore to
factory default, simply relearn the touch screen into the panel
again. The learn in process begins by clearing the touch screen
memory. To keep memory clear, learn the touch screen into a
Simon XT panel that has no online service supported.
Specifications
Compatibility
Simon XT (version 1.3 and later)
Power
6 VDC, 500 mA
Batteries
Four 1.5 V, Alkaline, AAA
Dimensions (W × H × D)
5.5 × 3.6 × 1.1 in. (140 × 92 × 28 mm)
Color
White
Operating environment
Temperature
32 to 104°F (0 to 40°C)
Relative humidity
0 to 90% noncondensing
P/N 466-2383 • REV A • ISS 02MAR10
Regulatory information
FCC
This device complies with part 15 of the FCC rules.
Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved
by the party responsible for compliance could void
the user's authority to operate the equipment.
FCC ID: B4Z-924-2WTTS
IC: 1175C-9242WTTS