GE IC755CxW07CD SERIES User Manual

GE IC755CxW07CD SERIES User Manual

Operator interface
Table of Contents

Advertisement

GE
GFK-2847F
Intelligent Platforms
QuickPanel+ Operator Interface
IC755CxW07CDx (7" Display)
IC755CxS10CDx (10" Display)
IC755CxS12CDx (12" Display)
IC755CxS15CDx (15" Display)
User Manual
For public disclosure

Advertisement

Table of Contents
loading

Summary of Contents for GE IC755CxW07CD SERIES

  • Page 1 GFK-2847F Intelligent Platforms QuickPanel+ Operator Interface IC755CxW07CDx (7” Display) IC755CxS10CDx (10" Display) IC755CxS12CDx (12” Display) IC755CxS15CDx (15” Display) User Manual For public disclosure...
  • Page 2 It is understood that GE may make changes, modifications, or improvements to the equipment referenced herein or to the document itself at any time. This document is intended for trained personnel familiar with the GE products referenced herein.
  • Page 3 Safety Symbol Legend Indicates a procedure, condition, or statement that, if not strictly observed, could result in personal injury or death. Warning Indicates a procedure, condition, or statement that, if not strictly observed, could result in damage to or destruction of equipment.
  • Page 4: Contact Information

    Contact Information If you purchased this product through an Authorized Channel Partner, then contact the seller directly. General Contact Information Online technical support and GlobalCare http://support.ge-ip.com Additional information http://www.ge-ip.com/ Solution Provider solutionprovider.ip@ge.com Technical Support If you have technical problems that cannot be resolved with the information in this manual, please contact us by telephone or email, or on the web at http://support.ge-ip.com...
  • Page 5: Table Of Contents

    Contents 1 Introduction ............................7 1.1 Specifications ............................7 1.1.1 General Specifications ........................7 1.1.2 Physical Specifications and Mounting Options..................8 1.1.3 Environmental Specifications ......................9 1.2 QuickPanel Hardware User Features ......................10 1.2.1 Physical Overview .......................... 10 1.2.2 Status Indicators ..........................14 2 Pre-installation Checks......................... 15 2.1 Unpacking and Inspection ........................
  • Page 6 4.7.6 Audio (MIC IN) Details (only applicable to IC755CxW07CDx)............... 45 4.7.7 SD Card Slot ..........................46 5 Operation............................47 5.1 Touchscreen Display ..........................47 5.1.1 Adjusting the Display Brightness ....................... 47 5.1.2 Configuring the Backlight......................... 47 5.1.3 Re-calibrating the Touchscreen ......................48 5.2 Keyboard .............................
  • Page 7: Introduction

    1 Introduction The QuickPanel Operator Interface is an all-in-one microcomputer designed for maximum flexibility. The design is based on an advanced ARM core microprocessor to combine a high-resolution touchscreen operator interface with a variety of communications options. Users can connect to most industrial equipment through the QuickPanel communications ports.
  • Page 8: Physical Specifications And Mounting Options

    Item IC755CxW07CDx IC755CxS10CDx IC755CxS12CDx IC755CxS15CDx 1x Mic In (Mono) (3.5 mm jack) 1x Line Out (Stereo) (3.5 mm jack) Audio 1x Line Out (Stereo) (3.5 mm jack) Noise voltage: 1500 V p-p Noise Immunity Pulse duration: 1µs Rise time: 1ns +24 V dc ±20% Rated Voltage +12/24 V dc ±20% (3-pin connector)
  • Page 9: Environmental Specifications

    1.1.3 Environmental Specifications For additional product standards and agency Note Install the QuickPanel in a well-ventilated location that is not exposed to dust, approvals, refer to Appendix corrosive gases or liquids, rain, strong ultraviolet light or direct sunlight, and meets the specifications listed in the following table.
  • Page 10: Quickpanel + Hardware User Features

    1.2 QuickPanel Hardware User Features In addition to the primary touchscreen interface, the QuickPanel Operator Interface supports a variety of communication ports. 1.2.1 Physical Overview The following diagrams display the physical layout of the QuickPanel , including locations of status LEDs, communications ports, and connectors. Status SD Card Indicator LED...
  • Page 11 SD Card Status Indicator LED Touchscreen Input LAN1 MICRO COM2 COM1 LINE LAN2 Power Host Ports IC755CxS10CDx Hardware Features Introduction GFK-2847F User Manual 11 For public disclosure...
  • Page 12 IC755CxS12CDx Hardware Features GFK-2847F QuickPanel+ Operator Interface User Manual For public disclosure...
  • Page 13 SD Card Status Indicator Touchscreen Input LINE LAN2 LAN1 MICRO COM2 COM1 Power Host Ports IC755CxS15CDx Hardware Features Introduction GFK-2847F User Manual 13 For public disclosure...
  • Page 14: Status Indicators

    1.2.2 Status Indicators The QuickPanel has a tri-color LED that provides visual status indications for IC755CxW07CDx and IC755CxSxxCDx units. 1.2.2.1 Status LED Operation LED State QuickPanel State Operating system starting Amber, solid Normal operating state Green, solid Green, blinking Backlight off Red, blinking Backlight failure Power not applied to the unit...
  • Page 15: Pre-Installation Checks

    Customer Care. Before initial powerup, inspect the unit for loose or damaged components. If damage is found (such as bent component leads or loose components), contact GE Intelligent Platforms for additional instructions.
  • Page 16 QuickPanel + Operator Interface Battery (Qty 1) (pre-installed) Serial Port Connector (Qty 1) Power Connector (Qty 1) Mounting Brackets (Qty 4) Protective Sheet (Qty 1) (not shown) Gasket (Qty 1) (not shown, pre-installed) IC755CxW07CDx Example Package Contents GFK-2847F QuickPanel+ Operator Interface User Manual For public disclosure...
  • Page 17: Basic Setup

    2.2 Basic Setup The QuickPanel Operator Interface is shipped ready for use after initial configuration. To power up the unit, connect a dc power supply using the supplied quick-connect plug. Depending on the application, you may also want to connect and configure optional input devices, communications ports, and expansion adapters.
  • Page 18: Initial Startup

    2.3 Initial Startup You will need the following: • A Safety Extra Low Voltage (SELV) and Limited Energy Circuit or SELV and Class 2 dc power supply. • The power terminal block is supplied with the product. For voltage and requirements, refer to the Input Power specifications in the table, General Specifications.
  • Page 19: Initial Configuration

    2.3.2 Initial Configuration When you first start up the QuickPanel , a few configuration steps are necessary. � � To configure the QuickPanel Tap Start , point to Settings, then tap Control Panel. From the Control Panel, double-tap Date and Time to configure the system clock. From the Control Panel, double-tap System to configure a Network Device Name.
  • Page 20: Shutdown

    2.6 Shutdown There are no specific dangers associated with a power failure or other unplanned shutdown of the QuickPanel . In general, programs are retained in flash memory and user data can be retained in battery-backed SRAM. Some operating system settings are retained only with user intervention.
  • Page 21: Software

    3 Software This chapter provides general information on the QuickPanel software and procedures for completing some of the most common tasks. 3.1 Operating System Refer to http://windows. Microsoft Windows Embedded Compact 7 is the operating system for the QuickPanel . It microsoft.com.
  • Page 22: Copying Project To Sd Card

    3.4 Copying Project to SD Card This is a custom utility for transferring Proficy Machine Edition View and Control projects between compatible QuickPanel units via SD cards. Ensure that the copy or update operation is complete such as no busy or wait cursor displays) before disconnecting power.
  • Page 23: Updating A Machine Edition Project

    3.5 Updating a Machine Edition Project You can update a Machine Edition application currently stored on the QuickPanel with a revision stored on a flash device, such as a SD card. � � To update a Machine Edition project Insert the flash device containing an upgraded version of the Machine Edition project into the appropriate port.
  • Page 24: Ftp Server

    3.6 FTP Server The FTP server included with the QuickPanel supports standard (RFC 959). It does not support SFTP or implicit FTPS, which uses different ports and is based on SSH rather than SSL. The FTP server is configured with the Quick Panel+ Setup Tool. By default, the server is not enabled.
  • Page 25: Http Server

    3.7 HTTP Server The HTTP server included with the QuickPanel supports standard (RFC 2616). The HTTP server is configured with the Quick Panel+ Setup Tool. By default, the server is not enabled. Once enabled, a background program will run, waiting for clients to connect. The default web page is located in \Windows\www\wwwpub on the QuickPanel Operator Interface.
  • Page 26 Notes GFK-2847F QuickPanel+ Operator Interface User Manual For public disclosure...
  • Page 27: Installation

    4 Installation This chapter provides the following procedures for installing the QuickPanel Operator Interface: • Installing the Protective Sheet • Choosing a Mounting Location • Panel Mounting • Mounting on a VESA Arm • Installing and Replacing the Battery • Connectors 4.1 Installing the Protective Sheet �...
  • Page 28: Choosing A Mounting Location

    4.2 Choosing a Mounting Location Refer to the section, When mounting the QuickPanel Operator Interface, make sure the mounting area allows Environmental Specifications. room to insert and remove the SD card, cables, and mounting brackets. Choose a location that will allow natural convection air flow from bottom to top of the QuickPanel enclosure.
  • Page 29: Panel Mounting

    4.3 Panel Mounting To mount the QuickPanel in an enclosure, you will need: • One #2 Phillips head screwdriver • Mounting brackets (supplied) The IC755CxW07CDx, IC755CxS10CDx, and IC755CxS12CDx mounting holes are located on the top and bottom sides of the unit. IC755CxW07CDx Mounting Holes IC755CxS10CDx and IC755CxS12CDx Mounting Holes Installation...
  • Page 30 The IC755CxS15CDx mounting holes are located on the top, bottom, and sides of the unit. IC755CxS15CDx Mounting Holes GFK-2847F QuickPanel+ Operator Interface User Manual For public disclosure...
  • Page 31: Installation Procedure

    4.4 Installation Procedure Observe the following guidelines to properly mount and install the QuickPanel Operator Interface: • To properly mount the QuickPanel , the enclosure should be of metal material. • The metal enclosure panel should ensure proper thickness and rigidity suitable to minimize impact to the QuickPanel To order replacement gaskets, •...
  • Page 32 Verify that the gasket is present and properly seated in the bezel channel located on the sides of the unit. Insert the QuickPanel into the mounting panel cutout. Insert the hook of the mounting bracket into the mounting hole as displayed in the following figure.
  • Page 33: Mounting On A Vesa Arm

    4.5 Mounting on a VESA Arm The QuickPanel can be installed on a commercially available Video Electronics Standards Association (VESA) MIS-D arm, stand, or apparatus that is listed to comply with the UL1678 standard. � � To mount the QuickPanel : use the mounting holes located on the back of the Refer to the mounting arm unit as displayed in the following figures.
  • Page 34: Installing And Replacing The Battery

    4.6 Installing and Replacing the Battery Batteries may present a risk of fire, explosion, or chemical burn if mistreated. Do not crush, disassemble, short-circuit, or dispose of in fire. Use of batteries not specified for use with the Warning QuickPanel product may present a risk of fire or explosion.
  • Page 35: Ic755Cxw07Cdx

    4.6.1 IC755CxW07CDx � � To install or replace the battery for the IC755CxW07CDx Replace the battery for the IC755CxW07CDx only with battery part number IC755ACCBATT. Caution Remove the battery cover by pressing down while sliding outward. IC755CxW07CDx Battery Cover Removal Connect the battery harness connector to the header, noting keyed orientation.
  • Page 36 Wrap the harness connector around to match the following figure. Do not let the harness connector go above the tab. Harness Connector Orientation Slide the battery cover into place, taking care not to pinch the harness connector. GFK-2847F QuickPanel+ Operator Interface User Manual For public disclosure...
  • Page 37: Ic755Cxsxxcdx

    4.6.2 IC755CxSxxCDx � � To install or replace the battery for the IC755CxSxxCDx Replace the battery for the IC755CxSxxCDx only with battery part number IC755ACCBATTNL. Caution Remove seven screws from the back cover. IC755CxSxxCDx Screw Locations (Back Cover) Gently press on either side tab to release the back cover. Side Tab for Cover Release Lift up the back cover to remove.
  • Page 38 The battery will be exposed on the back of the unit. Battery Part Number IC755ACCBATTNL IC755CxSxxCDx Battery Gently remove the coin battery and replace with a new one, noting the polarity of the battery. Replace the battery cover and tighten all screws to 0.5 Nm (4.4 in-lb). GFK-2847F QuickPanel+ Operator Interface User Manual For public disclosure...
  • Page 39: Connectors

    4.7 Connectors 4.7.1 Power Connector Pin-out for IC755CxW07CDx and IC755CxSxxCDx To connect the power supply, Connector: Terminal Euro (Tyco Electronics 284539-3) refer to the section, Connecting Mating Connector: (Tyco Electronics 284510-3) Input Power. Pin # Signal Name Pin-out +24 V dc †...
  • Page 40: Serial Port

    4.7.2.2 Setting an IP Address The QuickPanel Operator Interface provides two methods to set an IP address: • DHCP (Dynamic Host Configuration Protocol) The network server assigns an IP address during QuickPanel initialization. (You must be connected to the network.) There must be a DHCP server on the connected network for a valid IP address to be assigned.
  • Page 41 4.7.3.2 IC755CxSxxCDx Serial Port Details For an IC755CxS12CDA serial • Terminal blocks are supplied. port, refer to • The mating terminal blocks support stranded 30 to 14 AWG (0.05 to 2.00 mm Appendix C IC755CxS12CDA wires. Serial Port Details. • At a minimum, the cable must be rated for 75°C (167 °F) or more.
  • Page 42 Example of Full-duplex (RS–485 Mode) Connection COM2 DIP Switch Setting DIP SW ON/OFF DIP SW ON/OFF GFK-2847F QuickPanel+ Operator Interface User Manual For public disclosure...
  • Page 43 Example of Half-duplex (RS–485 Mode) Connection COM2 DIP Switch Setting DIPSW ON/OFF DIPSW ON/OFF Installation GFK-2847F User Manual 43 For public disclosure...
  • Page 44: Universal Serial Bus (Usb) Ports

    4.7.4 Universal Serial Bus (USB) Ports 4.7.4.1 USB Host Port Details for IC755CxW07CDx and IC755CxSxxCDx The QuickPanel has two full-speed USB 2.0 host ports. A variety of third party USB peripheral devices are also available. Each connected USB device requires a specific driver.
  • Page 45: Audio (Line Out) Details For Ic755Cxw07Cdx And Ic755Cxsxxcdx

    4.7.5 Audio (LINE OUT) Details for IC755CxW07CDx and IC755CxSxxCDx Interface: LINE OUT (stereo) Number of Ports: One Connectors: φ3.5 mm jack Maximum output level: 1 Vrms Pin # Signal Name Pin-out Lineout R Lineout L 4.7.6 Audio (MIC IN) Details (only applicable to IC755CxW07CDx) Interface: MIC IN (monaural) Number of Ports: One...
  • Page 46: Sd Card Slot

    4.7.7 SD Card Slot The QuickPanel is equipped with one standard SD Card port. SD/SDHC memory cards are supported. The SD card slot is spring-loaded for easy insertion and removal. 4.7.7.1 SD Card Storage Details Connectors: SD card slot (push in-push out method) Card support: SD/SDHC memory card Maximum capacity: 32 GB Note During insertion, observe the orientation of the SD card as displayed in the...
  • Page 47: Operation

    5 Operation 5.1 Touchscreen Display The QuickPanel Operator Interface features a LED Backlit LCD touchscreen display with two-point touch technology. The touch technology is based on projected capacitance, which allows tracking of the finger without pressured contact and is conducive to smooth scrolling and multi-touch gesturing capability.
  • Page 48: Re-Calibrating The Touchscreen

    5.1.3 Re-calibrating the Touchscreen The QuickPanel touchscreen is shipped pre-calibrated. However, If there are any issues with touchscreen responsiveness, it may need to be re-calibrated. � � To re-calibrate the touchscreen Open the QuickPanel+ Setup tool. Select the TouchPanel tab. Select Recalibrate Touch Screen.
  • Page 49: Keyboard

    5.2 Keyboard The QuickPanel Operator Interface can be configured to use either or both a hardware keyboard and a software emulation keyboard as operator data input devices. Typically, an optional external hardware keyboard is used when in development mode, while the included Soft Input Panel (SIP) is more applicable in an operational environment.
  • Page 50: Memory

    5.4 Memory 5.4.1 Dynamic RAM Memory The QuickPanel Operator Interface is equipped with dynamic RAM (DRAM). Part of the DRAM is reserved for the Windows operating system and is not accessible by user applications. The remaining memory is split between two functions: an object store for temporary file storage and the main memory for running programs.
  • Page 51: Modifying Memory Allocation

    5.4.2 Modifying Memory Allocation � � To change the memory allocation From the Control Panel, double-tap System to display the System Properties window. From the Memory tab, drag the slider bar to divide into Storage and Program memory. The amount of memory allocated to and used by each area is displayed in the window.
  • Page 52 Notes GFK-2847F QuickPanel+ Operator Interface User Manual For public disclosure...
  • Page 53: Appendix A Product Certifications And Installation Guidelines

    Appendix A Product Certifications and Installation Guidelines The QuickPanel Operator Interface is intended for use in industrial environments and, when properly installed, shall comply with the agency approvals listed in this chapter. Agency Approvals Note The agency approvals listed in the following table and on the Declaration of Conformities are believed to be accurate;...
  • Page 54 Changes or modifications to this unit that are not expressly approved by GE Intelligent Platforms could void the user’s authority to operate the equipment.
  • Page 55: Appendix B Orderable Part Numbers

    Appendix B Orderable Part Numbers QuickPanel Operator Interface Part Numbers Description Part Number QuickPanel 7” Color TFT Widescreen with Multi-touch Projected Capacitive Screen, 24 V dc Powered IC755CSW07CDx QuickPanel 7” Replacement Gasket IC755ACC07GAS QuickPanel 7” Accessory Kit - Replacement Mounting Clips, Power and Serial Port Connectors IC755ACC07MNT QuickPanel 7"...
  • Page 56 Notes GFK-2847F QuickPanel+ Operator Interface User Manual For public disclosure...
  • Page 57: Appendix C Ic755Cxs12Cda Serial Port Details

    Appendix C IC755CxS12CDA Serial Port Details • A terminal block is supplied. • The mating terminal block supports stranded 30-14 AWG (0.05 – 2.00 mm ) wires. • At a minimum, the cable must be rated for 75°C (167 °F) or more. •...
  • Page 58 Notes GFK-2847F QuickPanel+ Operator Interface User Manual For public disclosure...
  • Page 59: Index

    protective sheet 27 IP Address 40 Index Keyboard 49 external 49 Accessories SIP 49 part numbers 55 Audio LINE OUT 45 MIC IN 45 LED Operation status 14 Backlight adjusting 47 configuring 47 Machine Edition 22 Backup 7 updating a project 23 Backup Utility 21 Memory 50 DRAM 50...
  • Page 60 storage details 46 SD Card Slot 46 Serial Port 40 IC755CxS12CDA 41 IC755CxS12CDx 57 Serial Port Details IC755CxW07CDx 40 Setup basic 17 runtime 19 Shutdown 20 Soft Input Panel 49 Software 21 Specifications 7 environmental 9 general 7 physical and mounting 8 Startup 18 Status Indicators 14 Store Manager 21...
  • Page 62 1-800-433-2682 1-434-978-5100 GE Intelligent Platforms www.ge-ip.com GFK-2847F For public disclosure...

Table of Contents