HW1 HEAT ALARM
USER MANUAL
220-240 V AC 50 Hz mains powered heat alarm. 9V battery back-up.
WARNING: Wiring should be installed by a qualified electrician in accordance with local building standards. The wiring must conform to current regulations for
electrical installations. Check with local building and fire regulations for your property, to ensure compliance.
For the best protection, heat alarms should always be installed as part of a complete fire protection system that includes smoke alarms.
Class A2 detection. This heat alarm will sound a warning when the ambient temperature in a room is between 54°C and 70°C.
This heat alarm is not intended for any non-residential, commercial or industrial application, nor for any other purpose than described above.
Technical Support
Online: www.fireangel.co.uk/support
E-mail: technicalsupport@fireangel.co.uk
Phone: 0800 141 2561
Note: This user manual is also available in large text and
other formats. Please email: technicalsupport@sprue.com
or call 0800 141 2561 for further information.
2. INSTALLATION
Unwrap battery. Insert battery into battery compartment
2a
(match '+' to '+'). Remove dust cover. Press and hold the
test button for 5 seconds. The alarm will sound.
Push and twist the alarm clockwise onto the base plate.
2c
Turn the electricity supply back on and check that the
green LED is on.
If desired, the alarm can be interconnected with up to 11 other smoke, heat or carbon monoxide alarms
from the FireAngel range via the 'I' connector. (See Optional Interconnecting Feature).
3. SILENCE FEATURE
In a known false alarm, the alarm can be silenced temporarily.
Press and hold the
3a
button for
5 seconds.
Your alarm features 'Silence' technology. In the event of a known false alarm you can temporarily silence it by pressing the
button. After 10 minutes your alarm will automatically sound 2 chirps and return to full sensitivity.
The red LED on the front of the alarm will flash once every 8 seconds to show that it is in Silence mode.
The alarm will sound continuously and the red LED will flash every second when the alarm senses dangerous heat levels. NEVER
IGNORE ANY ALARM. If an alarm is sounding, it is warning you of a potentially hazardous situation. Do not ignore it. Ignoring the
alarm may result in injury or death. If your heat alarm activates and you are not absolutely certain of the source of the problem,
get everyone out of the house immediately.
5. MAINTENANCE
Test the alarm every month.
5a
Press the test button for 5 seconds.
The alarm will sound.
5c
Do not use cleaners or solvents.
5e
Replace the alarm every
10 years.
TROUBLESHOOTING GUIDE
If the green LED does not light when the alarm
is connected to power:
If your heat alarm does not sound during
testing:
If your heat alarm activates when no smoke is
visible:
If your heat alarm sounds unusual or 'chirps'
intermittently:
If you experience frequent unwanted alarms:
© 2018 Sprue Safety Products Ltd.
Vanguard Centre, Coventry CV4 7EZ,
United Kingdom.
www.sprue.com
Switch off electricity supply.
2b
Remove the baseplate by twisting the alarm anti-clockwise.
Connect the house wiring to the power connector provided.
Ensure a permanent connection is made in a suitable junction
box (not provided).
Brown (live)
No connection should
Blue (neutral)
be made to the mains
Black or grey (interlink)
electricity supply
Earth
earth terminal.
Terminate house
wiring earth in spare
connector.
Fit the base to ceiling
using the screws
Brown
provided. Feed the
Blue
wiring through the
hole in the base plate
and connect the
power adapter to
the alarm.
The alarm will silence for
3b
10 minutes.
5b
Vacuum your alarm
every 3 months.
5d
Do not paint the alarm.
Do not use any other test method except
the process described in this manual.
• Check that your heat alarm is connected to the power
supply and that the battery is correctly installed.
• Check that your alarm is connected to the power supply and that the
battery is installed correctly.
• If testing after installation, allow a few seconds for the alarm to settle.
• Push and hold the centre of the test button firmly for 5 seconds.
• Check that the alarm is properly connected to the mains power.
• Check the location of your heat alarm.
• Clean the heat alarm.
• Check the location of your heat alarm.
• Check that your heat alarm is definitely the source of the chirping; make
sure the noise isn't coming from another alarm.
• If the alarm 'chirps' every 32 seconds and the red LED flashes at the
same time - replace the battery.
• If the alarm 'chirps' every 32 seconds without a red LED flash, a fault is
indicated - contact Techincal Support.
• Check the location of your heat alarm.
• Clean the heat alarm.
1
BS 5446-2: 2003
Licence No:
KM694292
300mm
2d
Press and hold the test button for 5 seconds.
The alarm will sound.
Junction box
(not provided)
Baseplate
White
Power connector
IMPORTANT: The circuit used to Power the alarm must be a 24 hour voltage circuit that cannot be turned off by a switch.
In accordance with BS 5839: Part 6, we recommend: For mains powered alarms, each with an integral standby supply, the mains
electricity supply should take the form of either a) an independent circuit at the dwelling's main circuit board, in which case no
other electrical equipment should be connected to this circuit (other than a dedicated monitoring device installed to indicate
failure of the mains electricity supply to the alarms); or b) a separately electrically protected, regularly used local lighting circuit.
Check with local building and fire regulations for your property, to ensure compliance.
Ensure dust cover is removed before operation.
The red LED on the front of the alarm should flash once every 32 seconds (approx.) to show that the alarm sensor is actively
monitoring for heat. When the test button is pressed, the alarm will flash once every 8 seconds for 8 minutes.
4. OPTIONAL INTERCONNECTING FEATURE
Up to 12 FireAngel mains smoke (SW1), heat (HW1) or carbon monoxide (CW1) alarms
For multiple alarm installations use a 'three core and earth' style cable between all the alarms to be interconnected.
4a
Connect the interconnect cable between each alarm's power connector from the white wire.
10
WIRING KEY
= Earth
= Interconnect
= Neutral
= Live
4b
Test each alarm and ensure every connected alarm
sounds within 10 seconds.
On an interconnected network, only the alarm that senses the fire will sound and flash its LED. Other connected alarms will sound a
The interconnect wire (minimum 0.75 mm2 cable) must be treated as Live, it should be insulated and sheathed.
6a
When the alarm battery is low, the alarm will 'chirp'
and the LED will flash every 32 seconds.
Replace the batteries and re-install.
6d
(See 'Installation')
Your alarm requires 1 x 9V (PP3) battery. Under normal use, the battery should last approximately one year.
Use of a battery other than those recommended here may have a detrimental effect on the alarm:
Sprue Safety Products Ltd warrants to the original purchaser that its enclosed smoke alarm be free from defects in materials and workmanship
under normal residential use and service for a period of 5 (five) years from the date of purchase (not including the replaceable battery). Provided
product is sent back to Sprue Safety Products with proof and date of purchase, Sprue Safety Products Ltd hereby warrants that during the
5 (five) year period commencing from the date of purchase Sprue Safety Products Ltd, at its discretion, agrees to replace the unit free of charge.
The warranty on any replacement HW1 alarm, will last for the remainder of the period of the original warranty in respect of the alarm originally
purchased – that is from the date of original purchase and not from the date of receipt of the replacement product. Sprue Safety Products Ltd
reserves the right to offer an alternative product similar to that being replaced if the original model is no longer available or in stock. This
warranty applies to the original retail purchaser from the date of original retail purchase and is not transferable. Proof of purchase is required.
This warranty does not cover damage resulting from accident, misuse, disassembly, abuse or lack of reasonable care of the product, or
applications not in accordance with the user manual. It does not cover events and conditions outside of Sprue Safety Products Ltd's control,
such as Acts of God (fire, severe weather etc.). It does not apply to retail stores, service centres or any distributors or agents. Sprue Safety
Products Ltd will not recognise any changes to this warranty by third parties.
Sprue Safety Products Ltd shall not be liable for any incidental or consequential damages caused by the breach of any expressed or implied
warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited
in duration for 5 (five) years.
This warranty does not affect your statutory rights. Except for death or personal injury, Sprue Safety Products Ltd shall not be liable for any loss
of use, damage, cost or expense relating to this product or for any indirect, or consequential loss, damages or costs incurred by you or any
other user of this product.
DISPOSAL
Waste electrical products should not be disposed of with your other household waste. The alarm is ideally suited for disposal within the
waste electronic and electrical equipment (WEEE) recycling scheme.
Please recycle where facilities exist. Check with your local authority, retailer or contact our Technical Support team for recycling/disposal
advice as regional variations apply.
Once the batteries are removed, the low battery warning chirp will stop. The batteries should always be removed before disposal.
Do not attempt to open. Do not burn.
1. POSITIONING
300mm
OPTIONAL LOCKING FEATURE
Remove locking plug from baseplate.
2e
Insert into hole between base plate and alarm
can be interconnected on a single network.
Mains 230V AC
Power Supply
warning but will not flash their LED. Do not connect more than 12 devices.
6. LOW BATTERY WARNING
6b
Switch off electricity supply.
6c
Twist alarm
anti-clockwise to
remove from base
plate and disconnect
power adapter.
Always test the alarm after replacing
6e
the batteries.
Duracell MN1604, Gold Peak: GP1604S, Raymax: 6F22.
WARRANTY AND DISPOSAL
Your heat alarm is suitable for the kitchen,
garage and loft.
Heat alarms should be sited at least 300mm
from light fittings and walls. Ideally as central
as possible in the room. Do not install heat
alarms on a wall.
Install your heat alarm at a distance no greater
than 5.3m from the farthest wall, no greater
than 5.3m from a door to any room in which a
fire might start and no greater than 5.3m from
the next heat or smoke alarm.
If there is fluorescent lighting, heat alarms
should be installed at least 1500mm from
these fittings and wiring. Keep any wiring at
least 1000mm from fluorescent lighting.
Do not use circuits containing fluorescent light
fittings or dimmer switches.
If there is fluorescent lighting, heat alarms
should be installed at least 1500mm from
these fittings and wiring. Keep any wiring at
least 1000mm from fluorescent lighting.
Do not use circuits containing fluorescent light
fittings or dimmer switches.
Locations of alarms must be compliant
with either BS 5839: Part 6 or relevant
Building Regulations if in any doubt.
To enable removal of the alarm,
withdraw the locking plug with a
pair of pliers.
To other alarms
if fitted
10

Advertisement

loading
Need help?

Need help?

Do you have a question about the HW1 and is the answer not in the manual?

Questions and answers

Summary of Contents for FireAngel HW1

  • Page 1 5 (five) year period commencing from the date of purchase Sprue Safety Products Ltd, at its discretion, agrees to replace the unit free of charge. The warranty on any replacement HW1 alarm, will last for the remainder of the period of the original warranty in respect of the alarm originally If your heat alarm does not sound during •...
  • Page 2 électrique principal du logement et, dans ce La garantie sur tout remplacement de détecteur HW1 durera jusqu’à la fin à l’adresse supporttechnique@fireangel.fr ou nous appeler au 0800 cas, aucun autre équipement électrique ne doit être connecté à ce circuit de la période de garantie d’origine concernant le détecteur acheté...