Brivis Models: Contour Series Promina Series Advance Series AD Series Evaporative Air Coolers Installation Manual...
Page 2
This appliance must be installed in accordance with: • Manufacturer’s Installation Instructions • Current AS/NZS 3000 • Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed only by an Authorised Person. For continued safety of this appliance it must be installed and maintained in accordance with the manufacturer’s instructions.
5. Installation - Promina & Contour 5�1 Dropper Duct Installation and Fitting the Cooler ����������������������������������������������������������������������������������������������������������� 10 5�2 Fitting Brivis Promina Optional Winter-Seal �������������������������������������������������������������������������������������������������������������������11 5�3 Fitting the Brivis Promina & Brivis Contour Series Cooler ���������������������������������������������������������������������������������������������11 6. Installation - Brivis Advance 6.1 Brivis Advance Series Dropper Duct Specific ��������������������������������������������������������������������������������������������������������������� 12 6�2 Fitting Brivis Advance Series Optional Winter-Seal ������������������������������������������������������������������������������������������������������...
Page 4
11.1 Brivis AD Dropper Duct Specific ���������������������������������������������������������������������������������������������������������������������������������� 20 11.2 Installing the Dropper Duct and fitting the Brivis AD Cooler ���������������������������������������������������������������������������������������� 20 11�3 Brivis AD Winter Seal Installation �������������������������������������������������������������������������������������������������������������������������������� 21 11�4 Wiring the Brivis AD to the Programmable and Manual Wall Control �������������������������������������������������������������������������� 22 12. Brivis AD Water Connection 12�1 Inlet Connection ���������������������������������������������������������������������������������������������������������������������������������������������������������� 23 12�2 Brivis AD Float Valve Setting Details ��������������������������������������������������������������������������������������������������������������������������...
F66DS F86DS Brivis AD Series AD66 / AD66D AD86 / AD86D Brivis AD BAL Series AD56 / AD56D AD66 / AD66D AD 86 * Brivis Contour and Brivis Advance Plus are fitted with a Motorised Winter-Seal. Brivis Evap AC IM...
For safety and warranty purposes, appliances that may be damaged or incorrect must not be installed or operated under any circumstances� Installation of damaged or incorrect appliances may contravene local government regulations� Brivis disclaims any liability or responsibility whatsoever in relation to the installation or operation of damaged or incorrect appliances�...
DO NOT remove water supply line, (braided hose) from rear of cooler� 2.3 INSTALLING THE WALL CONTROL The Brivis Networker, Manual and Programmable Wall Controls are part of a sophisticated control system� Controllers with Auto mode constantly monitor the temperature inside the house, switching the Cooler ON and OFF ...
50mm (see diagram below)� Water diverter channel Dropper Duct Flashing This diagram is for Brivis Promina and Brivis Contour Series Models. NOTE 3.4 DROPPER DUCT INSTALLATION GUIDELINES •...
The roof access point is 6m above ground level • The structure is unsound All service works are governed by the Rinnai Australia Pty Ltd Safe Work Method Statements (SWMS) for Evaporative Coolers and Working at Heights� Brivis Evap AC IM...
5. INSTALLATION - PROMINA & CONTOUR 5.1 DROPPER DUCT INSTALLATION AND FITTING THE COOLER • The dropper duct size for all Brivis Promina & Brivis Contour Series models is 550mm X 550mm� • Brivis Promina & Brivis Contour Series Coolers MUST use a dropper duct with an out turned flange (15-20mm). ...
5.2 FITTING BRIVIS PROMINA OPTIONAL WINTER - SEAL • For detailed instructions please refer to Brivis Series 5 Winter-Seal Installation Instructions provided with the Brivis Series 5/6 Winter-Seal kit� •...
NOTE 6.3 FITTING THE BRIVIS ADVANCE UNIT • The Brivis Advance Series Cooler chassis comprises latching brackets to secure the unit to the dropper box� To assist with connection it is important the dropper box has a 15-20mm outward turned flange. • In addition to the latching brackets the unit MUST BE secured to the dropper box and the cooler chassis with screws, refer below for method: 1�...
Connect the cable to the Brivis Networker connection lead terminal block at the Cooler� If the Cooler is integrated with a Brivis Heater(s) then simply connect the wiring to the Brivis Networker in parallel with the Heather's circuit� Classic Series Heaters require an interface module to enable connection.
Installer set-up program� This Brivis Networker will now become the Slave Brivis Networker, and the installer parameters can no longer be accessed from this Brivis Networker� The Master Brivis Networker MUST now be used to access the installer parameters�...
Brivis Networker Advanced Programming Manual No� 400 (Available on request from Brivis Customer Service)� As the Brivis Networker is polarity sensitive when more than one Cooler is installed on a Brivis Networker all the Coolers should be wired in parallel (see diagrams below)�...
Turn the power supply at the Cooler OFF to save the new ID number� • Repeat the sequence for each Cooler� • Then follow the Brivis Networker Advanced Programming Instructions to allocate the Coolers to their respective zones� Brivis Evap AC IM...
8.2 TANK WATER QUALITY MANAGEMENT. The Brivis Advance, Brivis Promina and Brivis Contour's Series electronic water level sensor automatically maintains the correct water level within the tank� The Brivis Advance and Brivis Promina Series models is programmed to periodically flush the tank and refill it with clean water, depending on the operating conditions, and automatically maintain the water quality within the tank. The Brivis Contour Series is fitted with an AquaSave module that ...
Pre-wet is 5 to 7 minutes 9.3 PROGRAMMABLE WALL CONTROL MODELS IN AUTO MODE These models operate similar to Brivis Networker and Manual wall control models but in auto mode the Pre-wet operates slightly differently. If the Cooler has been OFF for longer than 15 minutes it will begin with a 2 minute Pre-wet, then turn OFF the pump and start the fan�...
Lift up and remove the 4 PVC support posts, disengaging the pad’s restraining angle brackets� • Slide the side pad frames out from the formed brackets at the base of the frames� • Remove the side pad frames and external panel assemblies� Brivis Evap AC IM...
11. INSTALLATION - BRIVIS AD 11.1 BRIVIS AD DROPPER DUCT SPECIFIC • For Brivis AD models 66 and 86 the dropper box size is 650 mm x 650 mm� • For Brivis AD 56 the dropper box size is 550 mm x 550 mm�...
11. INSTALLATION - BRIVIS AD 11.3 BRIVIS AD WINTER SEAL INSTALLATION The Winter Seal can be fitted into the dropper duct before or after the dropper has been installed, but it is important to ensure that: • Dropper duct is square • The dropper duct seam and the large 45º fold-up corner are to the high side of the roof as shown in the drawing below, otherwise the flaps will not open correctly.
11.4 WIRING THE BRIVIS AD TO THE PROGRAMMABLE AND MANUAL WALL CONTROL • The Brivis AD coolers are supplied with a 20 m wall control loom pre-wired to the Cooler’s electronic module� • Ensure the wall control is positioned so that it is within reach of the Cooler, using the 20 m wire loom assembly supplied�...
12.1 INLET CONNECTION The water inlet connection point is in the Cooler base, which should be positioned on the low side of the roof� The connection is a 12 mm copper tube union (flare). 12.2 BRIVIS AD FLOAT VALVE SETTING DETAILS The Float Valve has been factory set so that the water fills initially to a level between the minimum and maximum level ...
12. WATER CONNECTION 12.5 BRIVIS AD BLEED SETTING INSTRUCTIONS • Loosen the thumb screw, firmly grip the over flow pipe, and rotate it. • Move the bleed tray further under the pad to increase the bleed rate or further away from the pad to decrease it� • Measure to confirm the required bleed rate and then tighten the thumb screw. Ensure the arrow of the overflow pipe assembly sits between the leg of the locking bracket.
8 minutes� 13.4 PROGRAMMABLE WALL CONTROL MODELS IN AUTO MODE These models operate similar to Brivis Networker and Manual wall control models but in auto mode the Pre-wet operates slightly differently. If the Cooler has been OFF for longer than 15 minutes it will begin with a 2 minute Pre-wet, then turn OFF the pump and start the fan�...
14.2 ISOLATING SWITCH - BRIVIS AD The Brivis AD Cooler has an isolating switch located on the side of the Cooler’s electronic control module� Access to the switch is by removing the appropriate pad or by inserting a screwdriver in the access hole provided in the corner post nearest to where the electronic control module is mounted, the latter option does not apply to AD BAL units�...
The motor is not hot, causing the auto-reset thermal overload switch in the fan motor to open circuit� • The motor speed sensor has not been damaged or displaced (where fitted). • That all electrical connections are secure, and if the motor will not start, call Brivis for service� 14.5 WHAT IF THE PUMP WILL NOT START? Check: •...
Cooler’s air output. IMPORTANT Door = 1�6m² Hinged Window = 0�3m² Sliding Window = 0�7m² Average ventilation area provided by various openings when fully opened� Brivis Models Number of average Highest Lowest size windows & doors Contour...
15-20mm 900mm 21 degrees al - 20 with 15-20mm 900mm 21 degrees Note: Brivis reserves the right to change specifications without notice with 1/2" BSP thread 40 mm metre wiring loom 40 mm Flange out Flange out 550mm x 550mm...