Brivis ICE DO-SC18Z9 Installation, Start-Up, Maintenance Instructions & User Operating Manual

Brivis ICE DO-SC18Z9 Installation, Start-Up, Maintenance Instructions & User Operating Manual

18 & 22 r410a

Advertisement

Brivis ICE
Models - 18 & 22 R410A
INSTALLATION, START-UP, MAINTENANCE
INSTRUCTIONS
&
USER OPERATING GUIDE
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLING & USING THIS PRODUCT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICE DO-SC18Z9 and is the answer not in the manual?

Questions and answers

Summary of Contents for Brivis ICE DO-SC18Z9

  • Page 1 Brivis ICE Models - 18 & 22 R410A INSTALLATION, START-UP, MAINTENANCE INSTRUCTIONS & USER OPERATING GUIDE PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING & USING THIS PRODUCT...
  • Page 2: Table Of Contents

    6.7 Oil Checking and Top Up ..................19 7.0 START-UP AND COMMISSIONING..................19 7.1 Sequence of Operation ..................20 7.2 Cooling Capacity / Air Flow .................21 7.3 Specifications ......................23 7.4 Commissioning Sheet ..................24 Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 3 2.0 SERVICE, MAINTENANCE AND WARRANTY..............30 2.1 Brivis Customer Care Program ................30 2.2 Brivis Customer Care Program Membership............31 2.3 ICE Warranty Card Form..................31 2.4 Terms of Warranty – Australia and New Zealand..........32 Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 4: Introduction

    1.1 Brivis ICE R410a Fixed Speed Range The Brivis ICE series is a refrigerated cooling split only type air conditioner designed for connection to compatible Brivis Ducted Gas Heaters. Brivis ICE utilises the heating system’s ductwork and air circulation fan to distribute cool, filtered refrigerated air.
  • Page 5: Codes / Regulations

    1.3 Codes / Regulations Brivis ICE units must be installed, serviced or repaired in accordance with these instructions and related regulations, codes, standards, and authorities. These include but may not be limited to: Ozone Protection and Synthetic Greenhouse Gas Management Regulations 1995 •...
  • Page 6: Starting Collars

    Adjust the level of the unit to ensure that the condensate drains from the evaporator drip tray (approx 10 - 15mm • incline from back to front) Fig. 3 - “P” TRAP ASSEMBLY Fig. 4 - “P” TRAP INSTALLATION Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 7: Outdoor Unit

    3 Phase Contactor Fan Run Capacitors Liquid Line Service Ball valve Suction Line Service Ball valve Liquid filter Drier HP Switch LP Switch Scroll Compressor Suction Accumulator Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 8: Typical Installation

    Ductwork and fittings must be sized to handle the total cooling airflow through the system on either whole home or • zoned basis If the Brivis Heater requires a remote thermistor installed in the supply air ductwork, position it in the supply air • starting collar (discharge pop) of the cooling coil (see Section 4.5) 4.1 Location...
  • Page 9: Condensate Drain / Safety Tray

    Safety Tray must also be separately drained, arranged to terminate in a position where the home owner can see if • water is dripping from the outlet. Please instruct the end user to call their Installer or Brivis Service should they notice water dripping from the Safety Tray drain outlet 4.3 Minimum Service Access...
  • Page 10: Brivis Heater Thermistor Position (If Applicable)

    A filter must be fitted into the system, and should be easily accessible for regular cleaning. Please refer to the guidelines for return air filter grilles accompanying the Gas Ducted Heater. 4.7 General Arrangement Drawings Fig. 8 - Indoor Unit Dimensions DI-XU22Z Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 11: Outdoor Unit Installation

    Means for disconnection (i.e. isolating switch and circuit breaker) shall be incorporated according to wiring rules. Wiring sizing is the responsibility of the installer as it depends on Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 12: Thermostat Control Wiring

    Time delays providing this protection are built into the recommended Brivis Controllers. When adding Brivis ICE to a system where a non-Brivis heater is installed, it is the installer’s responsibility to ensure that some form of time delay or other protection is installed to prevent the compressor from short cycling. Failure to do so may void warranty.
  • Page 13: Wiring Diagrams

    5.4 Wiring Diagrams Fig. 10 – Typical Outdoor Unit Wiring Diagram (DO-SC22Z9 shown) Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 14 Add-on refrigerative air-conditioning control. For more information please refer to the associated heater installer’s manual. For additional zone requirements a 'Brivis Network 516 module' (Part No. B023178) is required, which can then allow for control of up to four zone dampers and a refrigeration relay.
  • Page 15 Electronic Control Module Fuse 2A EARTH Fan Speed Red LED G W R 12AC Refrigeration Compressor Relay Electronic Thermostat Contact Brivis Technical Support for information on superseded Brivis Heaters. Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 16: General Arrangement Drawings & Clearance Requirements

    All brazing operations must be completed with a small steady stream of nitrogen passing through the pipe-work to • limit scale build up and moisture contamination Never use the unit compressor as a vacuum pump • Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 17: Piping Design

    If the indoor unit is located more than 5 metres above the outdoor unit, then a solenoid valve should be installed in the liquid line at the indoor unit, to prevent liquid refrigerant migrating back to the compressor in the off cycle. The solenoid shall be interlocked with the compressor. Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 18: Correction Factors: Vapour Line Sizing Vs. Cooling Capacity

    Superheat should be between 4 and 9K • Sub-cooling should be between 2 and 8K • Discharge gas temperature should not exceed 130° C in any circumstances • Do not overcharge. • Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 19: Oil Checking And Top Up

    1497 3689 1584 3857 1674 4031 1768 4210 Table 4 – Saturated Pressure-Temperature R410a FAILURE TO COMPLETE PROPER START UP AND COMMISSIONING MAY VOID BRIVIS PRODUCT WARRANY Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 20: Sequence Of Operation

    When the high or low pressure limiting switch trips the compressor and outdoor fan/s are disabled. The compressor and outdoor fan will remain off until the system is reset via thermostat or on/off switch. Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 21: Cooling Capacity / Air Flow

    1000 1025 1050 1075 1100 Air Flow L/s Airflow 1000 1025 1050 1075 1100 Dry Coil Wet Coil Table 6 – Coil Static Pressure Drop - DI-XU22Z Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 22 17.2 16.8 16.6 Minimum Air Flow 16.4 16.2 15.8 1000 Air Flow L/s Airflow Dry Coil Wet Coil Table 8 – Coil Static Pressure Drop - DI-XU18Z Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 23: Specifications

    910 x 790 × 677 910 x 790 × 684 Net Weight Duct Connection (Outlet) Ф450 Ф500 Duct Connection (Inlet) Ф400 Ф450 Condensate Drain Connection Table 9 – Technical Specification Data Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 24: Commissioning Sheet

    Outdoor air Temperature (Ambient) C DB Length of liquid line Length of suction line Liquid line Diameter Suction line Diameter Extra refrigerant quantity charged (if any) Supply voltage Actual voltage Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 25: Introduction

    • 1.1 Privacy Notification Brivis Climate Systems Pty Ltd is the registered owner of the Brivis brand. Brivis will collect "personal information’’ from you when you complete your warranty and maintenance registration form. This personal information is collected under the guidance of the Privacy Information Protection Act 1998.
  • Page 26: Appliance Operating Symbols

    When the Networker switches ON to COOL, a snowman symbol will appear on the screen • In both cases the FAN symbol will also appear on the display and appears rotating when the fan is running • Heating Cooling Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 27: Operating The Fan Only

    This code contains information that will enable Brivis to deal quickly and easily with anything that requires their attention. With many of them you will be asked to contact Brivis Service and pass on the message, the model and type of appliance.
  • Page 28: Locking/Unlocking The Networker

    PIN. You can immediately retry entering the PIN numbers, or if you cannot remember the PIN numbers, follow the procedure for resetting the PIN numbers. Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 29 Enter the Master PIN number “4919” using the correct button combination. • The screen will now display the message, “Valid PIN – User PIN numbers reset!” • Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd...
  • Page 30: Service, Maintenance And Warranty

    Brivis products are renowned for providing years of trouble free performance. To be at their most efficient performance, like most things, they need a little care. So to ensure that every Brivis unit is always in perfect condition we have established the Brivis Care Program for our valued customers.
  • Page 31: Brivis Customer Care Program Membership

    2.2 Brivis Customer Care Program Membership The Brivis Customer Care Program is designed to help you get the most out of your new unit. We will contact you before each winter or summer season with some terrific discounted offers for preventative maintenance services which will keep your Brivis unit in great condition! If you would like to join our Brivis Care Program please complete the following information with the warranty form.
  • Page 32: Terms Of Warranty - Australia And New Zealand

    2.4 Terms of Warranty – Australia and New Zealand Brivis Climate Systems Pty. Ltd. ABN 64 096 079 088, AU24752 61 Malcolm Rd, Braeside, VIC 3195. Definitions The terms listed below shall have the following meanings: means an independent service contractor authorised by Brivis or Brivis “Authorised Service Representative”...
  • Page 33 3.3 complies with clause 7 below (titled "Purchaser's Responsibilities"); 3.4 notifies Brivis within 30 days of a defect developing, that a claim is being made under this Warranty; and 3.5 provides, in support of the claim made under this Warranty, a Proof of Purchase.
  • Page 34 Travel, Transport & Access Costs 6.1 The Purchaser must pay freight charges, in-transit insurance expenses and travelling costs for repairs/replacements under this Warranty, that are required to be performed 100km or more from the nearest Brivis branch or Authorised Service Representative.
  • Page 35 For Australian Warranty Claims call 1300 Brivis (1300 274847) or send to Brivis Warranty Claims 61 Malcolm Road, Braeside VIC 3195. For New Zealand Warranty Service call 0800 WARMAIR (0800 9276 247) - Brivis only. The PURCHASER WILL BE CHARGED for work done or a service call(s) if:- the problem is not covered by these Terms of Warranty;...
  • Page 36 © 2013 Brivis Climate Systems Pty. Ltd. All rights reserved. No part of these documents may be used in any way or form without prior written consent from Brivis Climate Systems Pty Ltd. Part Number: B023897 Nov 2013...

This manual is also suitable for:

Ice do-sc22z9Ice di-xu18zIce di-xu22z

Table of Contents