Page 1
All manuals and user guides at all-guides.com LCR Meter LCR-6300/6200/6100/6020/6002 User's Guide VERSION: 1.04 ISO-9001 CERTIFIED MANUFACTURER...
Page 2
All manuals and user guides at all-guides.com This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of the Good Will company.
Page 3
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Safety Summary Warning Dangerous When you notice any of the unusual conditions listed below, immediately terminate operation and disconnect the power cable. Please contact the GWINSTEK service center representative for repair of the instrument.
Page 4
All manuals and user guides at all-guides.com Safety Summary Operating personnel must not remove instrument Keep Away From Live covers. Component replacement and internal Circuits adjustments must be made by qualified maintenance personnel. Do not replace components with the power cable connected. Under certain conditions, dangerous voltages may exist even with the power cable is removed.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Table of Contents 1. UNPACKING AND PREPERATION ...........11 Incoming Inspection ................ 11 Environmental Requirements ............12 Cleaning .................... 12 How to Remove the Handle ............13 2. OVERVIEW ..................14 Introduction ..................
Page 6
All manuals and user guides at all-guides.com Table of Contents 3. STARTUP....................21 Front panel ..................21 Rear Panel ..................22 Power On/Off ................. 22 3.3.1 Power On .................. 22 3.3.2 Power Off ................. 22 Warm‐up Time ................. 23 Connect to the Device Under Test (DUT) ........23 4.
Page 7
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 4.5.1 Enlarge Display ................ 49 4.5.2 Direct Comparison Function ..........50 5. SETUP KEY ..................51 [MEAS SETUP] Page ..............51 5.1.1 Source Output Impedance [SRC RES] ......... 52 5.1.2 Averaging Factor [AVG] ............
Page 8
All manuals and user guides at all-guides.com Table of Contents 6.1.5 TERMINATOR............... 72 6.1.6 Hand Shake ................72 6.1.7 Error Code ................73 6.1.8 Result ..................74 6.1.9 DATA BUFFER ..............74 6.1.10 DEFAULT SET ..............75 [SYSTEM INFO] Page ..............76 7.
Page 9
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.6.2 DISP:PAGE ................98 11.7 FUNCtion Subsystem ..............100 11.7.1 FUNCtion ................100 11.7.2 FUNCtion:IMPedance:AUTO ..........101 11.7.3 FUNCtion:IMPedance:RANGe ........... 101 11.7.4 FUNCtion:DCR:RANGe ............. 101 11.7.5 FUNCtion:RANGe:AUTO ..........102 11.7.6 FUNCtion:MONitor 1 /2.............
Page 10
All manuals and user guides at all-guides.com Table of Contents 11.11.8 COMParator:BEEP ............114 11.11.9 COMParator:OPEN ............114 11.12 LIST Subsystem ................115 11.12.1 LIST:PARAmeter ............115 11.12.2 LIST:STAT ..............115 11.12.3 LIST:BAND ..............116 11.13 CORRection Subsystem ............... 117 11.13.1 CORRection:OPEN ............
Page 11
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.18.1 SYSTem:SHAKehand............ 124 11.18.2 SYSTem:CODE ............. 124 11.18.3 SYSTem:KEYLock ............125 11.18.4 SYSTem:RESult.............. 125 11.19 Common Commands ..............125 11.19.1 *IDN? ................125 11.19.2 *TRG ................125 11.19.3 *SAV ................126 11.19.4 *RCL ................
Page 12
All manuals and user guides at all-guides.com Table of Contents Table of Figures Figure 1 -1 How to remove the handle ............. 13 Figure 2 -1 Disk Ready ..................19 Figure 2 -2 Screen Saved ..................19 Figure ...
Page 13
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Figure 1 1-6 APERture Subsystem Command Tree ........107 Figure 1 1-7 FETCh Subsystem Command Tree ..........108 Figure 1 1-8 COMParator Subsystem Command Tree ........111 Figure ...
Page 14
All manuals and user guides at all-guides.com Table of Contents List of Tables Table 2-1 Equivalent Circuit ................15 Table 2-2 Display Range ................... 16 Table 3-1 Front panel description ..............21 Table 3-2 Rear panel description ..............22 Table 4-1 Measurement parameter combinations .........
All manuals and user guides at all-guides.com LCR-6000 Series User Manual NPACKING AND PREPERATION This chapter describes how to set up and start the LCR-6000 Series LCR Meter. Incoming Inspection Environmental Requirements Cleaning How to Remove the Handle ...
UNPACKING AND PREPERATION If an abnormality is detected, contact the company and Note transport the meter to your nearest GW INSTEK Instruments sales or service office. Save the packing box, shock-absorbing material, and packaged items as you received them in case you need to mail the instrument to an authorized GW Instek distributor or service center.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 1.4 How to Remove the Handle A handle kit is attached to the LCR-6000 Series: Figure 1 -1 How to remove the handle Retracted Carrying Position Extended Remove Handle (Lift the handle perpendicular to the unit while pulling it in the direction of 1.)
2.1 Introduction Thank you for purchasing an LCR-6000 Series LCR meter. The GW INSTEK LCR-6000 Series is a general-purpose LCR meter for incoming inspection of components, quality control, and laboratory use. The LCR-6000 Series is used for evaluating LCR...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 2.2 Main Specifications and Features 2.2.1 Test Function Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, Rp-Q, R-X, DCR, Z-θr, Z-θd, Z-D, Z-Q 2.2.2 Equivalent Circuit Serial and Parallel Table ...
All manuals and user guides at all-guides.com Overview NOTE *1. Measurement speed in 300kHz, typical. 2.2.5 Trigger Mode Includes Internal, Manual, External and Bus Trigger. 2.2.6 Basic Accuracy 0.05%@SLOW/MED 0.1%@FAST 2.2.7 Display Range Table 2 -2 Display Range Parameter Display Range 0.00001uH ~ 9999.99H 0.00001pF ~ 9999.99mF...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 2.3.2 Test Signal Level 10.00mV- 2.00V (± 10%) CV mode:10.00mV- 2.00V(± 6%) 100.0uA- 20.00mA (± 10%) CC mode:100.0uA- 20.00mA(± 6%) @2VMax DCR: ± 1V(2Vpp), Square wave, 3Hz up 0.033A(Max), Output impedance fixed 30Ω 2.3.3 Output impedance 30Ω, 50Ωand 100Ω...
All manuals and user guides at all-guides.com Overview 2.4.3 List Sweep Points There is a maximum of 10 points. Sweep parameters Test frequency, test voltage, test current. Comparator function of list sweep The comparator function enables you to set one pair of lower and upper limits for each measurement point.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Save Screen After a USB disk has been inserted into the USB host port of the LCR meter and if the meter detects that the USB disk is usable, the meter will show “USB Disk Ready.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual TARTUP This chapter describes names and functions of the front panel, rear panel, and screen display and provides the basic procedures for operating the LCR- 6000 Series. Front panel summary ...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 3.4 Warm‐up Time LCR-6000 Series is ready to be used as soon as the power-up sequence has completed. However, to achieve the specification accuracy, first warm up the instrument for 30 minutes.
All manuals and user guides at all-guides.com Measure Key EASURE KEY This section includes the following information: MEAS DISPLAY page OPEN/SHORT page LIST SETUP page LIST MEAS page 4.1 [MEAS DISPLAY] Page When the [Measure] key is pressed, the [MEAS DISPLAY] page appears.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Figure 4 -1 [MEAS DISPLAY] Page 4.1.1 Measurement Function [FUNC] The LCR-6000 Series simultaneously measures four components of complex impedance (parameters) in a measurement cycle. These include a primary parameter, a secondary parameter and two monitor parameters.
All manuals and user guides at all-guides.com Measure Key Table 4 -3 Measurement and Monitor parameter descriptions Parameter Description Capacitance value measured using the series equivalent circuit model Capacitance value measured using the parallel equivalent circuit model Inductance value measured using the series equivalent circuit model Inductance value measured using the parallel equivalent circuit model...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 4.1.2 Impedance Range [RANGE] Impedance range mode To achieve the best measurement result, it is recommended to set the impedance range mode to “Auto range”. When using “Hold range”, errors in measurement results may occur if the measured value exceeds the full scale of the selected range.
All manuals and user guides at all-guides.com Measure Key Table 4 -5 Effective measurement range for the impedance range when in HOLD state. Range Impedance Effective measurement range range 10Ω 0 - 10Ω 30Ω 10Ω-100Ω 100Ω 100Ω-316Ω 300Ω 316Ω-1kΩ 1kΩ...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Procedure for setting the impedance range [RANGE] Step 1. Press the [Measure] key. Step 2. Use the cursor key to select the [RANGE] field. Step 3. Use the soft-keys to select the impedance range mode or impedance range.
All manuals and user guides at all-guides.com Measure Key Procedure for setting test frequency [FREQ] Step 1. Press the [Measure] key. Step 2. Use the cursor key to select the [FREQ] field. Step 3. Use the soft-keys or numeric entry keys to enter the test frequency.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Table 4 -12 LCR-6002’s predefined test frequencies that can be selected by using INCR+/DECR‐ INCR+/DECR- 10Hz 50Hz 60Hz 100Hz 120Hz 1kHz 2kHz 4.1.4 Trigger Mode [TRIG] LCR-6000 Series supports four trigger modes: INT (internal), EXT (external), MAN (manual) and BUS (RS- 232).
All manuals and user guides at all-guides.com Measure Key 4.1.5 Test Signal Voltage/Current Level [LEVEL] The LCR-6000 Series’ test signal voltage/current level can be set as the effective value (RMS value) of a sine wave of the test frequency from the unit’s internal oscillator.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 4.1.6 Measurement Speed [SPEED] SLOW, MED and FAST can be selected for LCR-6000 Series. SLOW mode will result in more stable and accurate measurement results. Procedure for setting measurement speed mode Step 1.
All manuals and user guides at all-guides.com Measure Key 26.5 88.5 24.5 100k 88.5 24.5 300k 88.5 24.5 4.1.7 Measurement log [LOG] The LCR-6000 has an internal data buffer that record up to 10000 measurement readings. These readings can be saved to an external USB drive in a .csv file format.
Page 39
All manuals and user guides at all-guides.com LCR-6000 Series User Manual SAVE TO USB Saves the recorded readings in the buffer to an external USB flash drive. The internal buffer is cleared after this operation. CLEAR Clears the internal buffer. BUFFER SAVE &...
All manuals and user guides at all-guides.com Measure Key Before saving the recorded readings in the internal buffer to the external USB flash drive, remember to plug the external USB drive into the USB port on the front panel. The recorded readings will be saved in a subdirectory named MEAS DATA, whose parent directory will have the same name as the LCR-6000 model being used.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Figure 4 -2 [OPEN/SHORT] Page 4.2.1 Open Correction [OPEN] The LCR-6000 Series’ OPEN correction capability cancels errors due to the stray admittance (G, B) in parallel with the device under test (Refer to Figure 4 -3). Figure ...
All manuals and user guides at all-guides.com Measure Key Disables open correction. MEAS OPEN Starts open correction (AC). DCR OPEN Starts open correction (DC). Step 4. Press the [MEAS OPEN] or [DCR OPEN] soft-key. A dialog message, “Open-circuit the test terminals” will appear. Step 5.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Step 1. Press the [Measure] key. Step 2. Press the [OPEN SHORT] soft-key. Step 3. Use the cursor key to select the [SHORT] field. Soft-key Function Enables short correction. Disables short correction.
Page 44
All manuals and user guides at all-guides.com Measure Key To specify frequency points and perform open correction Step 1. Press the [Measure] key. Step 3. Press the [OPEN SHORT] soft-key. Step 3. Use the cursor key to select the [SPOT] field. Step 4.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual To specify frequency points and perform short correction Step 1. Press the [MEAS SHORT] soft key, a dialog message, “Short-circuit the test terminals”, will be displayed. Step 2. Connect the test fixture to the BNC terminals and short-circuit the test terminals.
All manuals and user guides at all-guides.com Measure Key Figure 4 -5 [LIST SETUP] Page 4.3.1 Measurement Function [FUNC] Select the primary and the secondary measurement here. 4.3.2 Test Mode [MODE] The [LIST MEAS] page will execute a list of up to 10 swept frequency or amplitude tests.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Trigger Mode Function Trigger by the meter’s internal trigger source. Trigger by pressing the trigger button. Trigger by sending a signal to the trigger pin on the handler interface. Trigger by the RS-232 port.
All manuals and user guides at all-guides.com Measure Key 4.3.4 List Point and Limit Modes The List measurement feature supports up to 10 list points as well as measurement limit values. Each list point can be turned on or off. To configure the list points: Step 1.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 4.4 [LIST MEAS] Page The [LIST MEAS] page will appear when you press the [Measure] key and then the [LIST MEAS] soft-key. Figure 4 -6 [LIST MEAS] Page On the [LIST MEAS] page, the list points are swept and the measurement results are compared to the limits.
All manuals and user guides at all-guides.com Measure Key Trigger mode When entering LIST MEAS for the first time, the system will set Trig Mode to MAN and automatically performs a measurement. Trig Mode Function Internal Trigger. All ten list points are swept continuous.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual There are 4 available trigger modes in the [LIST MEAS] page. Trigger Modes Function Trigger by the meter’s internal trigger source. Trigger by pressing the trigger button. Trigger by sending a signal to the trigger pin on the handler interface.
Page 52
All manuals and user guides at all-guides.com Measure Key Soft-key Function SAVE & STOP Stops the recording and saves the recorded readings in the internal buffer to an external USB flash drive. The internal buffer will be cleared after the save operation. If an external USB flash drive is not plugged in, the meter will not stop the ongoing recording.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 4.5 [ENLARGE DISPLAY] Page Only four measurement values will be shown in this simplified display mode: The primary measurement parameters, the secondary measurement parameters and two monitored parameters such as △, △%, Iac or Vac, etc.
All manuals and user guides at all-guides.com Measure Key Figure 4 -7 [ENLARGE DISPLAY] Page 4.5.2 Direct Comparison Function The Direct Comparison function can be turned on in the [BIN SETUP] page. When the number of bins is set to 1 in the [BIN SETUP] page, the Direct Comparison function will be activated for the [ENLARGE DISPLAY] mode.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual ETUP KEY This section includes the following information: MEAS SETUP page BIN SETUP page BIN MEAS page BIN COUNT page Every time or everywhere you can press the [Setup] key to open the [MEAS SETUP] page.
All manuals and user guides at all-guides.com Setup Key In the [MEAS SETUP] Page, you can configure each of the following measurement controls with the cursor placed in the corresponding field. Measurement Function [FUNC] Impedance range [RANGE] Test Frequency [FREQ] ...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Soft-key Function 30Ω 30Ω 50Ω 50Ω 100Ω 100Ω 5.1.2 Averaging Factor [AVG] The averaging feature allows you to obtain moving average values of successive measurement results. You can specify the averaging factor from integer 1 to integer 256.
All manuals and user guides at all-guides.com Setup Key test. -2V voltage is applied to the device under test. Bias Voltage range Resolution 0.01V ≦ DC BIAS ≦ 2.50V 0.01V -2.50V≦ DC BIAS ≦ -0.01V 0.01V 5.1.4 Auto LCZ Function [AUTO LCZ] Auto LCZ Function can help you to select a proper measurement parameter.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Procedure for setting monitor parameters (monitor 1 and monitor 2) Step 1. Press the [Setup] key. Step 2. Use the cursor key to select [MON 1] or [MON 2] field. Step 3.
All manuals and user guides at all-guides.com Setup Key NOTE In situations when the actual measuring Vac or Iac goes beyond the extent that the ALC can regulate, a warning message, “Failed! ALC can’t regulate!”, will be shown at the bottom of the screen to indicate to the operator that the ALC can no longer regulate Vac/Iac.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 5.2 [BIN SETUP] Page Press [Setup] key and press the [BIN SETUP] soft-key to open [BIN SETUP] page. This page allows you to configure the LCR-6000 Series’ built-in comparator. The built-in comparator can sort DUTs into a maximum of 10 levels (BIN1 through BIN9 and OUT) using up to nine sets of primary parameter limits along with one set of secondary parameter limits.
All manuals and user guides at all-guides.com Setup Key Figure 5 -2 [BIN SETUP] Page 5.2.1 Measurement Function [FUNC] The LCR-6000 Series simultaneously measures four components of the complex impedance (parameters) in a measurement cycle. These include primary parameter, secondary parameter and two monitor parameters.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Figure 5 -3 Page Comparator Workflow Sorting Start COMP=ON BIN1 <Primary<BIN1 …. BIN9 <Primary<BIN9 AUX=ON AUX=ON Lower<Secondary<Upper Lower<Secondary<Upper Display: OUT AUX NG Display: BIN1-9 AUX NG Display: BIN1-9 OK Display: OUT NG Output: NG Output: NG...
All manuals and user guides at all-guides.com Setup Key 5.2.3 Auxiliary Bin [AUX] After AUX is turned on, DUTs that do not fall within the primary parameter limit values are sorted as OUT. In addition, DUTs that fall within the primary parameter limits but are out of the secondary parameter limits are sorted into the auxiliary (AUX) bin.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Absolute mode[ABS] Absolute value (Δ) = UNKNOWN value – nominal value Figure 5 -4 Absolute mode Includes the point ● ○ Excludes the point Percentage mode [PER] Deviation percentages (%) = Absolute value (Δ)/nominal value ×...
All manuals and user guides at all-guides.com Setup Key Sequential mode[SEQ] Figure 5 -6 Sequential mode Includes the point ● ○ Excludes the point In Sequential mode, the comparison limit values are based on the absolute value of the measurement. The nominal value does not need to participate in operation.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 5.2.5 Nominal value for tolerance mode You must configure the nominal value when you use tolerance mode as the limit mode for the primary parameter. In sequential mode the nominal value does not affect sorting.
All manuals and user guides at all-guides.com Setup Key Soft-key Function 1-BINS Set to 1 bin 2-BINS Set to 2 bins 3-BINS Set to 3 bins 4-BINS Set to 4 bins 5-BINS Set to 5 bins 6-BINS Set to 6 bins 7-BINS Set to 7 bins 8-BINS...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Figure 5 -7 [BIN MEAS] Page This page provides the following information: FUNC, RANGE, FREQ, LEVEL, TRIG, LEVEL, SPEED: These conditions can be set from [MEAS DISPLAY] page. Comparator function ON/OFF [COMP].
All manuals and user guides at all-guides.com Setup Key Soft-key Function Turns OFF the COMP function Turns ON the COMP function 5.3.2 Auxiliary Bin [AUX] After AUX is turned on, DUTs that do not fall within the primary parameter limit values are sorted as OUT. In addition, DUTs that fall within the primary parameter limits but out of the secondary parameter limits are sorted into the auxiliary (AUX) bin.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 5.4.1 Counter Function [COUNT] The number of DUTs sorted into each bin is counted while the unit sorts the DUTs into the appropriate bins using the comparator function. When the maximum count of 99999999 is reached, the counting operation stops and the overflow message “--------”...
All manuals and user guides at all-guides.com System Configurations YSTEM CONFIGURATIONS This section includes the following information: SYSTEM CONFIG page SYSTEM INFO page SYSTEM SERVICE page 6.1 [SYSTEM CONFIG] Page When the [Measure] or [Setup] key is pressed, followed by the [SYSTEM] bottom soft-key, the [SYSTEM CONFIG] page appears.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Figure 6 -1 [SYSTEM CONFIG] Page 6.1.1 Setting the system date and time LCR-6000 Series features a built-in 24-hour clock. To change the date Step 1. Press the [Measure] or [Setup] key. Step 2.
All manuals and user guides at all-guides.com System Configurations Soft-key Function HOUR INCR+ Increases the hour in steps of 1. HOUR DECR- Decreases the hour in steps of 1. MINUTE INCR+ Increases the minute in steps of 1. MINUTE INCR- Decreases the minute in steps of 1.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual If you forget your password, please contact your local NOTE GW Instek distributor or GWInstek at www.gwinstek.com / marketing@goodwill.com.tw. 6.1.3 KEY BEEP Setting Key tone settings. To set up the beep feature Step 1.
All manuals and user guides at all-guides.com System Configurations Soft-key Function 1200 Sets the baud rate to 1200. 9600 Sets the baud rate to 9600. 38400 Sets the baud rate to 38400. 57600 Sets the baud rate to 57600. 115200 Sets the baud rate to 115200.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Soft-key Function Turn off the Hand Shake feature. Turn on the Hand Shake feature. 6.1.7 Error Code If the error code setting is set to on, the meter will return error codes if the wrong command or an invalid command is received to help you to debug your control program.
All manuals and user guides at all-guides.com System Configurations 6.1.8 Result If the Result setting it set to Auto, the meter will automatically send out the measurement results each time a test is finished; this setting is convenient especially when the meter is working with a sorting machine. The meter will start a test after receiving the trigger signal and then returns the test result to the sorting machine without the need to receive a ‘fetch?’...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 6.1.10 DEFAULT SET To reset setting values (MEAS SETUP) and offset values (OPEN SHORT) to factory default, use the DEFAULT SET setting. The device can be quickly restored to its factory settings.
All manuals and user guides at all-guides.com System Configurations 6.2 [SYSTEM INFO] Page When the [Measure] or [Setup] key is pressed followed by [SYSTEM] bottom soft-key, and then the [SYSTEM INFO] soft-key, the [SYSTEM INFO] page appears. There are no configurable options in the [SYSTEM INFO] page.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual ILE OPERATION This chapter provides information on the file operation of the LCR-6000 Series. You can save up to 10 files into the internal non-volatile memory. 7.1 [FILE] Page When the [Setup] key is pressed followed by the [FILE] bottom soft-key, the [FILE] page appears.
All manuals and user guides at all-guides.com File Operation 7.1.1 [MEDIA] The Media field is used to select the media source from either the meter’s internal memory or an external USB flash drive. A maximum of up to 10 files can be accessed from either source.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 7.1.3 Auto save data to last file [AUTO SAVE] You can save the modified data into the last used file when the instrument power key is pressed. To turn on/off the AUTO SAVE function Step 1.
All manuals and user guides at all-guides.com Handler Interface ANDLER INTERFACE This chapter provides information about the LCR-6000 Series’ built-in handler interface. It includes: Pin Assignment Circuit Diagram Timing Chart The LCR-6000 Series’ built-in handler interface outputs signals that indicate the end of a measurement cycle, the result of bin sorting by the comparator.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 8.1 Pin Assignment Figure 8 -1 Pin Assignment Output Pins Table 8 -1 Handler Interface Signals ~ Output Pins Pin names Signal descriptions The sorting result is within bin1. O_BIN_1 Active low.
All manuals and user guides at all-guides.com Handler Interface Over fail occurs on the secondary measurement parameter. Active O_S_OVER low. (The signal on this pin is available only after AUX is turned on.) Over fail occurs on the primary measurement parameter. Active O_P_OVER low.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 8.2 Connection Electrical parameters Interface power requirements: +12.4V~36VDC, 0.2A(Min). Output circuit: Built-in pull-up resistors are internally connected to the collector pin of the output transistors. The output pins are isolated by photocouplers.
All manuals and user guides at all-guides.com Handler Interface Circuit of output pins Figure 8 -3 Circuit of output pins (Bin sorting, Index, EOM) EXT.DCV R 4.99k OUTPUT Maximum sourcing current: 5mA. Maximum sinking current: 50mA 8.3 Timing Chart for Handler Interface Figure ...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual XAMPLES This chapter covers basic measurement procedures as well as basic L, C, and R measurement theory. It also offers various measurement hints. After the descriptions of basic measurement procedures, practical measurement examples are shown using LCR-6000 Series.
All manuals and user guides at all-guides.com Examples Figure 9 -1 Basic Measurement Procedure Start Setup measurement conditions: [FUNC] [LEVEL] [FREQ] Connect the test fixture CORRECTIONS OPEN TEST SHORT TEST Connect DUT Perform measurement 9.2 Example This paragraph describes a practical example of measuring a ceramic capacitor.
Page 91
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Step 1. Turn the LCR-6000 Series ON. Step 2. Set up the measurement conditions by filling in the fields on the MEAS DISPLAY page. Move to the FUNC field using the cursor ...
Page 92
All manuals and user guides at all-guides.com Examples Move to the SHORT TEST or SPOT field using the cursor keys. Connect the clips to a shorting bar as shown below: Press the [MEAS SHORT] soft-key and then the [OK] soft-key. Wait until the “Correction finished”...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual performed continuously by the internal trigger, and the measured Cs and D values of the capacitors are displayed as shown below: Figure 9 -2 Measurement results...
All manuals and user guides at all-guides.com Remote Control EMOTE CONTROL This chapter provides the following information to remotely control the LCR- 6000 Series via the RS-232C: About RS-232 Select Baud Rate About SCPI LCR-6000 Series can use the RS-232 interface to communicate with the computer to complete all the instrument functions.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Figure 1 0-2 PC - LCR-6000 Series connection uses a null modem connection Pin2 RxD Pin2 TxD Pin3 Pin3 Pin5 GND Pin5 Make sure the controller you connect to LCR-6000 ...
All manuals and user guides at all-guides.com Remote Control 10.3 SCPI Language Standard Commands for Programmable Instruments (SCPI) is fully supported by the RS-232 interface. LCR-6000 Series ONLY supports the SCPI Language. NOTE:...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual OMMAND REFERENCE 11.1 Terminator :The EOI line is asserted by New Line or ASCII Line Feed character. <NL> (Decimal 10, Hex 0x0A, or ASCII ‘\n’) 11.2 Notation Conventions and Definitions The following conventions and definitions are used in this chapter to describe RS-232 operation.
All manuals and user guides at all-guides.com Command Reference Figure 1 1-1 Command Tree Example function :imp? :mon1 :imp :type {…} rang? Example: function:imp:type Cp-D function Subsystem Command Level 2 type Level 3 Cp-D Parameter The basic rules of the command tree are as follows. Letter case (upper and lower) is ignored.
Page 99
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Every command and character parameter has at least two forms, a short form and a long form. In some cases they will be the same. The short form is obtained using the following rules.
All manuals and user guides at all-guides.com Command Reference 11.4 Header and Parameters The commands consist of a command header and parameters. (See the following.) Example: comp:nom 100.0e3 Header Parameter Headers can be of the long form or the short form. The long form allows easier understanding of the program code and the short form allows more efficient use of the computer.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.5 Command Reference All commands in this reference are fully explained and listed in the following functional command order. DISPlay Subsystem FUNCtion Subsystem FREQuency Subsystem VOLTage Subsystem ...
All manuals and user guides at all-guides.com Command Reference 11.6 DISPlay Subsystem The DISP Subsystem command group sets the display page. Figure 1 1-2 Command Tree Example 11.6.1 DISP:LINE The :LINE command enters an arbitrary comment line of up to 30 ASCII characters in the comment field.
Page 103
All manuals and user guides at all-guides.com LCR-6000 Series User Manual COUNT. LISTMEAS [or LIST] Sets the display page to LIST MEAS. SETUP [or MSET] Sets the display page to MEAS SETUP. CORRECTION [or CSET] Sets the display page to CORRECTION.
All manuals and user guides at all-guides.com Command Reference 11.7 FUNCtion Subsystem The FUNCtion subsystem command group sets the measurement function, the measurement range, monitors parameter control. Figure 1 1-3 FUNCtion Subsystem Tree FUNCtion {Cs-Rs,Cs-D, Cp-Rp,Cp-D, Lp-Rp,Lp-Q, Ls-Rs,Ls-Q, R-Q,R-X, Z-thr(Z-θr),Z-Thd(Z-θd) Z-D,Z-Q, DCR}...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Query Response <function> Example SEND> FUNC?<NL> RET> Cp-D<NL> 11.7.2 FUNCtion:IMPedance:AUTO The FUNCtion:IMPedance:AUTO command sets the impedance’s LCZ Automatic selection. Command FUNC:IMPedance:AUTO {ON,OFF, 0,1} Syntax Example SEND> FUNC:IMP:AUTO ON<NL> Query Syntax FUNC:IMPedance:AUTO? Query Response {on,off}<NL>...
All manuals and user guides at all-guides.com Command Reference Query Response <0-8><NL> Example SEND> FUNC:DCR:RANG?<NL> RET> 0<NL> 11.7.5 FUNCtion:RANGe:AUTO The FUNCtion:RANGe:AUTO command sets the auto range to ON or OFF. Command FUNC:RANGe:AUTO {off(hold),on(auto),NOMinal} Syntax Parameter Where, {off(hold),on(auto),NOMinal} is: off(or hold): Sets the auto range to off.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual FREQuency Subsystem The FREQuency command sets the oscillator frequency. The FREQuency? query returns the current test frequency setting. Figure 1 1-4 FREQ Subsystem Command Tree [:CW] FREQuency {value,MIN,MAX} Command FREQ[:CW] {<value>,MIN,MAX} Syntax...
All manuals and user guides at all-guides.com Command Reference 11.8 LEVel Subsystem The Level subsystem sets the oscillator’s output voltage/current level and source output impedance. Figure 1 1-5 LEVel Subsystem Command Tree 11.8.1 LEVel:VOLTage (=VOLTage[:LEVel]) The LEVel:VOLTage or VOLTage[:LEVel] command sets the oscillator’s output voltage level.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.8.2 LEVel:CURRent (=CURRent[:LEVel]) The LEVel:CURRent or CURRent[:LEVel] command sets the oscillator’s output current level. Command LEVel:CURRent {<value>,MIN,MAX} Syntax or CURRent:LEVel {<value>,MIN,MAX} Parameter Where, <value> Is the numeric data (NR1, NR2 or NR3). MIN Sets to the minimum value of current.
All manuals and user guides at all-guides.com Command Reference Note The suffix unit can’t be used with this command. This command CANNOT be used in LIST SWEEP. DISPLAY page and CORRECTION page. 11.8.4 LEVel:ALC (=AMPlitude:ALC) The LEVel:ALC or AMPlitude:ALC command enables the Automatic Level Control (ALC).
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.9 APERture Subsystem The APERture subsystem command sets the integration time of the ADC and the averaging rate. Figure 1 1-6 APERture Subsystem Command Tree APERture {SLOW,MED,FAST} <averaging rate value:NR1> Command APERture {SLOW,MED,FAST} Syntax...
All manuals and user guides at all-guides.com Command Reference 11.10 FETCh Subsystem The FETCh subsystem command group is a sensor-only command which retrieves the measurement data taken by measurement(s) initiated by a trigger, and places the data into the output buffer. Figure ...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.10.2 FETCh:IMPedance? The FETCh:IMPedance? query sets the latest measurement data of the primary parameter, secondary parameter, monitor1 and monitor2 results into the output buffer. Query Syntax FETCh:IMPedance? Query Response <NR3:primary value>,<NR3:secondary value>, <NR3:monitor1>,<NR3:monitor2>,<comparator result>...
All manuals and user guides at all-guides.com Command Reference 11.10.6 FETCh:LIST? The FETCh:LIST? query sets the latest LIST measurement data of the primary parameters, secondary parameters and comparator results into the output buffer. Only applicable when in the [LIST MEAS] page view. Query Syntax FETCh:LIST? Query Response...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.11 COMParator Subsystem The COMParator subsystem command group sets the comparator function, including its ON/OFF setting, limit mode, and limit values. Figure 1 1-8 COMParator Subsystem Command Tree :S TATe COMParator {ON,OFF}...
All manuals and user guides at all-guides.com Command Reference 11.11.2 COMParator:MODE The :COMParator:MODE command sets the limit mode of the comparator function. Command COMParator:MODE {ABS,PER,SEQ} Syntax Parameter Where,{ABS,PER,SEQ} is: Absolute tolerance mode Percent tolerance mode Sequential mode Example SEND> COMP:MODE PER<NL> Query Syntax COMParator:MODE? Query Response...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.11.5 COMParator:TOLerance:NOMinal The COMParator:TOLerance:NOMinal command sets the nominal value for the tolerance mode of the comparator function. Command COMParator:TOLerance:NOMinal <value> Syntax Parameter Where,<value> is: NR1, NR2 or NR3 A suffix multiplier can be used with this command. But the suffix unit F//H can’t be used.
All manuals and user guides at all-guides.com Command Reference A suffix multiplier can be used with this command. Example SEND> COMP:SLIM 0.0001,0.0010<NL> Query Syntax COMParator:SLIM? COMParator:secondary? Query Response <NR3:low limit>,<NR3:high limit> Example SEND> COMP:SLIM?<NL> RET> 1.00000e-04,1.00000e-03<NL> 11.11.8 COMParator:BEEP The :COMParator:BEEP command sets beep mode of the comparator function.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.12 LIST Subsystem The LIST or SWEEP Subsystem command group sets the List Sweep measurement function, including the sweep point setting and limit values for the limit function. Figure 1 1-9 LIST Subsystem Command Tree :PARAmeter LIS T...
All manuals and user guides at all-guides.com Command Reference Parameter Where,<n> is: NR1(1 to 10): List sweep point Query Response {on,off} Example SEND> LIST:STAT? 1<NL> RET> on<NL> 11.12.3 LIST:BAND The LIST:BAND command sets the List Sweep point value, limit mode and low/high limit values.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.13 CORRection Subsystem The CORRection subsystem command group sets the correction function, including the OPEN, SHORT and SPOT correction settings. Note The CORRection subsystem CANNOT work in [LIST MEAS] page. Figure ...
All manuals and user guides at all-guides.com Command Reference pass/fail<NL> //Finish or Undone 11.13.2 CORRection:OPEN:STATe The CORRection:OPEN:STATe command sets the OPEN correction function to ON or OFF. Command CORRection:OPEN:STATe {ON,OFF or 1,0} Syntax Parameter ON, 1 Set up the function is ON OFF,0 Set up the function is OFF Example...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.13.6 CORRection:SHORt:STATe The CORRection:SHORt:STATe command sets the SHORT correction function to ON or OFF. Command CORRection:SHORt:STATe {ON,OFF or 1,0} Syntax Parameter ON, 1 Set up the function is ON OFF,0 Set up the function is OFF Example...
All manuals and user guides at all-guides.com Command Reference Query Response {on,off} Example SEND> CORR:SPOT:STATe?<NL> RET> on<NL> 11.13.10 CORRection:SPOT:FREQuency The CORRection:SPOT:FREQuency command sets the frequency point for the specified frequency point correction. Command CORRection:SPOT:FREQuendy <value> Syntax Parameter value NR1,NR2 or NR3:Frequecny value. A suffix multiplier can be used with this command.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.14 TRIGger Subsystem The TRIGger subsystem command group is used to enable a measurement or a sweep measurement, and to set the trigger mode. Figure 1 1-11 TRIGger Subsystem Command Tree [:IMMediate] TRIGger :S OURce...
All manuals and user guides at all-guides.com Command Reference Parameter Where, is float value:from 1ms to 60.00s min: =0ms max: =60.000s Example SEND> TRIG:DLY 1<NL>//1.000s Query Syntax TRIGger:DELAY? TRIGger:DLY? Query Response {0.000s~60.00s} Example SEND> TRIG:DLY?<NL> RET> 1.000s<NL> 11.15 BIAS Subsystem The BIAS subsystem command group sets the DC BIAS switch to ON or OFF, and sets the DC bias voltage value.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 11.16 FILE Subsystem The FILE subsystem command group executes the file operation. Figure 1 1-13 FILE Subsystem Command Tree :S AVE FILE <File No.> :LOAD <File No.> :DELete <File No.>...
All manuals and user guides at all-guides.com Command Reference The FILE:LOAD <n> command recalls all user settings from specified file. Command FILE:LOAD <File No.> Syntax Parameter Where, <File No.> is: NR1 (0 to 9) Example SEND> FILE:LOAD 0<NL> 11.16.4 FILE:DELete Command FILE:DELete <File No.>...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Query Syntax SYSTem:CODE? Query Response {on,off} Example SEND> SYST:CODE?<NL> RET> OFF<NL> 11.18.3 SYSTem:KEYLock SYSTem:KEYLock command unlocks the keypad. Command SYST:KEYLOCK OFF Syntax or UNLOCK(UNLK) Example SEND> UNLOCK<NL> 11.18.4 SYSTem:RESult SYSTem:RESult command selects the test results send mode.
All manuals and user guides at all-guides.com Command Reference Note This command can be used in BUS trigger mode. *TRG = TRIG;:FETC? 11.19.3 *SAV *SAV = FILE:SAVE The *SAV command saves all user settings into the currently used file. Command *SAV Syntax Example...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual PECIFICATION This chapter describes the specifications and supplemental performance characteristics of the LCR-6000 Series: Specifications Dimensions Accuracy is defined as meeting all of the following conditions: Temperature: 23 ºC±...
Page 132
All manuals and user guides at all-guides.com Specification Test Frequency LCR-6300: 10Hz~300kHz LCR-6200: 10Hz~200kHz LCR-6100: 10Hz~100kHz LCR-6020: 10Hz~20kHz LCR-6002: 10Hz~2kHz Frequency range and resolution Frequency range(F) Resolution 10.00Hz ≦ F ≦ 99.99Hz 0.01Hz 100.0Hz ≦ F ≦ 999.9Hz 0.1Hz 1.000kHz ≦ F ≦ 9.999kHz 10.00kHz ≦...
Page 133
All manuals and user guides at all-guides.com LCR-6000 Series User Manual LCR-6020’s open/short trimming frequency point list 1.2k 1.5k 2.5k LCR-6002’s open/short trimming frequency point list 1.2k 1.5k Display Range Parameter Display Range 0.00001uH ~ 9999.99H 0.00001pF ~ 9999.99mF R, X, |Z| 0.00001Ω...
Page 134
All manuals and user guides at all-guides.com Specification Ranging: Auto, Hold and Nominal range. Total 9 Ranges. Equivalent Circuit: Serial and Parallel OPEN/SHORT Test : OPEN/SHORT Zeroing (ALL,SPOT) Files: built-in 10 files and USB Disk 10 files, 9999 Log File, 999 Picture File, 10000 Data (.csv) Beep Feature: OFF/PASS/FAIL...
All manuals and user guides at all-guides.com Accuracy CCURACY This section will explain the meter’s accuracy, measurement tolerance and how to test the meter’s performance. It includes: Accuracy Factors that decide accuracy The meters’ accuracy is affected by the tolerances from measurement stability, temperature variation, circuit linearity and the measurement repeatability.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 13.1 Accuracy 13.1.1 L, C, R |Z| Measurement Accuracy The accuracies of L, C, R, |Z| is equal to A , which is defined by: = ± [A× A )×...
All manuals and user guides at all-guides.com Accuracy 13.1.3 Accuracy for Q Q’s accuracy is defined below: (when Q × D <1) Where: is the measured Q value. is D’s accuracy. 13.1.4 Accuracy for ‘s accuracy is defined below: ...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 13.1.6 Accuracy for Rs When D (measured D value)≤0.1 The accuracy of R is defined as: × D [Ω] = 2πfL Where: is the measured X value[]. is the measured C value[F]. is the measured L value[H].
Page 140
All manuals and user guides at all-guides.com Accuracy Figure 1 3-1 The basic measurement accuracy A If the accuracy for the spot you are searching for falls right on the line, e.g. the horizontal thick line between values 0.25 and 0.65, then use the smaller value, 0.25, for the basic accuracy of the spot you are searching for.
All manuals and user guides at all-guides.com LCR-6000 Series User Manual Figure 1 3-2 Table for basic accuracy correction factor A 100m 150m 200m 500m [Vrms] Table 1 3-1 Impedance correction factors Measurement Measuring frequency K speed ...
All manuals and user guides at all-guides.com Accuracy Table 1 3-2 Temperature correction factor K Temp (ºC) Table 1 3-3 Correction factor for interpolated open/short trimming K Test frequency When test frequency equals to the open/short trimming frequency When test frequency is not equal to 0.0003 the open/short trimming frequency...
All manuals and user guides at all-guides.com LCR-6000 Series User Manual 13.3 Declaration of Conformity GOOD WILL INSTRUMENT CO., LTD. declare, that the below mentioned product Type of Product: Precision LCR Meter Model Number: LCR-6300, LCR-6200, LCR-6100, LCR-6020, LCR-6002 are herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Law of Member States relating to Electromagnetic Compatibility (2014/30/EU) and Low Voltage Directive (2014/35/EU).
Need help?
Do you have a question about the LCR Series and is the answer not in the manual?
Questions and answers