4.1.4.
Attach one end of the gas hose to the threaded outlet on the regulator (note that the fitting has a reverse thread). Attach the other end of
the gas hose to the threaded heater valve inlet (note that the fitting has a reverse thread). Ensure hose is routed so that it does not touch
any part of the heater, which will become hot during operation.
4.1.5.
Open the bottle valve and, using soapy water, check all joints for leaks.
5.
OPERATION
WARNING! Ensure that you read, understand and apply the safety instructions in Section 1.
"
5.1.
Lighting heater
5.1.1
Open the gas bottle valve.
5.1.2. Push the heater control knob down and turn it anticlockwise to the centre (full on) position and keep it held down.
5.1.3. After a few seconds bring a flame up to the bottom edge of the burner.
5.1.4. After the gas ignites keep the knob held down for a further 20 seconds then turn the control knob anticlockwise again to reduce the
heat output to the required level.
5.2.
Turning off heater
5.2.1
Turn the heater control knob clockwise to the full on position then push the knob down and continue to to turn it clockwise to the off
position.
5.2.2. Close the gas bottle valve.
5.3.
Changing propane bottle
5.3.1. Ensure the bottle valve is closed and then unscrew the POL nut and remove the regulator.
5.3.2. Loosen and wind back the three bolts in the clamp at the base of the heater support bracket and remove heater from bottle.
5.3.3. Fit heater to new propane bottle as in 4.1.2. and 4.1.3. Check for gas leaks as in 4.1.5.
INFRARED GAS HEATER
Model: LP13.V2
90/396/EEC Gas Appliance Directive
93/68/EEC CE Marking Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk
Declaration of Conformity
here is in conformity with the following standards and directives.
Signed by Mark Sweetman
The construction file for this product is held by the Manufacturer and may be inspected, by a national
authority, upon request to Jack Sealey Ltd.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
We, the sole importer into the UK, declare that the product listed
Date 14th June 2007
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
01284 757500
Web
01284 703534
email
fig.2
www.sealey.co.uk
sales@sealey.co.uk
LP13.V2 - 1 - 080607

Advertisement

loading