Forced airflow is not required. However, any increase in airflow will result in a
reduction of ambient temperature and improve the long-term reliability of all
equipment mounted in the rack space.
Note
For detailed dimensions of the device with either rack, DIN rail or panel hardware
installed, refer to
2.3.1

Mounting the Device on a DIN Rail

The RUGGEDCOM RS400 can be ordered with panel/DIN rail adapters preinstalled on
each side of the chassis. Use the adapters to mount the device to a standard 35 mm
(1.4 in) IEC/EN 60715 or TS35 DIN rail.
Mounting the Device
To mount the device to a DIN rail, do the following:
1.
2.
RUGGEDCOM RS400
Installation Manual, 01/2021, C79000-G8976-1016-11
"Dimension Drawings (Page
Hook the top teeth of the adapters onto the DIN rail.
1
2
2
Panel/DIN Rail Adapter
1
DIN Rail
2
Screw
3
Figure 2.1
Mounting the Device to a DIN Rail
Install one of the supplied #8-32 lock screws on either side of the device to
secure the adapters to the DIN rails.
Installing the Device
2.3.1 Mounting the Device on a DIN Rail
29)".
1
3
2
9