Advertisement

6.12 Operation Ambient conditions
Operation assurance
Storage assurance
EMC condition
Notes on Heat Dissipation:
- The temperature of camera housing must be kept less than 60°C.
Please provide sufficient heat dissipation depending on your installation.
Notes on Conformity of the EMC:
The adaptability of the safety standard of this camera is assured in the condition of combination with the following parts:
- USB Cable
- e-CON Cable
Parts:
-
e-CON connector
-
Shielded wire
Connection:
Please confirm the EMC adaptability when it combines with parts other than them.
Copyright © 2018 TOSHIBA TELI CORPORATION, All Rights Reserved.
Temperature: 0°C to +40 °C, Camera housing temperature: less than 60 °C
Humidity: 10% to 90% (no condensation)
Temperature : -20°C to +60°C
Humidity : +90% or less (no condensation)
EMI (Electro-Magnetic interference) : EN61000-6-4,
EMS (Electro-Magnetic susceptibility) : EN61000-6-2
USB3-KR1-A-MBS-030
3.0m, Shield cable
XN2A-1470
UL1533 (AWG28)
e-CON
1
GPIO(Line2)
2
GPIO(Line1)
3
GND
4
TRIG IN
FCC Part 15 Subpart B Class A
(OKI Electric Cable Co., Ltd.)
(Fabricated parts)
(OMRON Corporation)
(Hitachi Cable, Ltd.)
BNC
BNC
25
GPIO(Line2)
GPIO(Line1)
TRIG IN