Commissioning, operation, maintenance and
servicing
6.1

General information

Loss of degree of protection
Damage to device if the enclosure is open or not properly closed. The type of protection
specified on the nameplate is no longer guaranteed.
• Make sure that the device is securely closed.
Commissioning and operation with pending error
If an error message appears, correct operation in the process is no longer guaranteed.
• Check the gravity of the error.
• Correct the error.
• If the error still exists:
Violation of the maximum permissible operating pressure
Danger of injury or poisoning.
The maximum permissible operating pressure depends on the device version and the pressure
and temperature limits. The device can be damaged if the maximum permissible operating
pressure is exceeded. Hot, toxic and corrosive process media can be released.
• Take note of the information on the nameplate and/or in the technical specifications of the
Safety instructions
Compact Operating Instructions, 09/2018, A5E45779403002-01
CAUTION
WARNING
– Take the device out of operation.
– Prevent renewed commissioning.
WARNING
Ensure that the maximum allowable operating pressure of the device is not exceeded.
manual/operating instructions of the respective device!