Display
Contents
H66
Malfunction of Drying
heater operation
circuit.
H71
Demagnetizing current
failure.
(Circulation pump)
Malfunction of
Circulation pump.
Circulation pump
connector has come
off.
(Operation malfunction
of circulation pump.)
Detection contents
Open circuit or short circuit is caused in the
Drying heater circuit.
• Drying heater is not conducting in drying
operation.
• Drying heater is conducting in except of
drying operation.
The demagnetization current detection
circuit operates the specified times during
the circulation pump operation.
• Error data is memorized only.
• Error is not displayed.
The number of the circulation pump
rotations does not reach the rated number
of rotations.
Check point
(Open circuit of Drying heater circuit.)
• Check the relay connector has not come
off or if contact failure.
• Open circuit failure of the relay.
(Short circuit of Drying heater circuit.)
• Short circuit failure of the relay.
• Check the operation of the circulation
pump and replace it if necessary.
• Replace the controller unit(Power side).
• Check the contact failure of connector.
• Check the breakage of lead wire.
• Replace the circulation pump.
• Replace the controller unit(Power side).
55
NA-D106X1
Method to clear error
Power button off and
on again.
Not necessary
(In case of short
ciruit).
*Unit automatically
off the operation.
Continued the
operation and
unnecessary to clear
the error.
• Circulation pump
stop the
operation.
Power button off and
on again.