2.0 Product Information

2.5 Technical Data HR04-HR07

Model Number
PERFORMANCE DATA (50Hz)
F.A.D. litres/sec (cfm) @ 7 bar/102 psi
F.A.D. litres/sec (cfm) @ 10 bar/145 psi
PERFORMANCE DATA (60Hz)
F.A.D. litres/sec (cfm) @ 7 bar/102 psi
F.A.D. litres/sec (cfm) @ 10 bar/145 psi
PERFORMANCE
Power - kW (hp)
Noise Level - dBA
Starter Type
Drive Type
Operating Controls
Rotation Speed - rev/min 50Hz (60Hz)
Ambient Temperature Range °C (°F)
Maximum Relative Humidity %
Air Discharge Temp - °C (°F) above ambient
FACTORY SETTINGS
Nominal Pressure – bar (psi)
Minimum Pressure Valve – bar (psi)
Load/Cut-in Pressure – bar (psi)
Unload/Cut-out Pressure – bar (psi)
Servo Valve – bar (psi)
Vent Down Run Time @ 7 bar – sec
Vent Down Run Time @ 10 bar – sec
Pressure Display Units
Temperature Display Units
Vacuum Relief Valve
INSTALLATION
Dimensions D x W x H –mm
Weights - kg
Air Outlet Size - Rp
Minimum Room Volume - m
2
Air Inlet/Outlet Area - m
3
Ventilation Rate - m
/h
3
Cooling Air Flow m
/h (cfm)
Recommended Air Receiver Capacity - litres
COMPRESSOR OIL
Approved compressor oil
Oil Capacity – litres
ELECTRICAL
Starter reference 200/575V 3PH 60Hz DOL
Circuit diagram 200/575V 3PH 60Hz DOL
Starter reference 400V 3PH 50Hz SD
Circuit diagram 400V 3PH 50Hz SD
Starter reference 400/460 3PH 50/60Hz RS
Circuit diagram 400/460V 3PH 50/60Hz RS
_________________________________________________________________________________________
8
3
*Alternative speed settings may be required depending on application and duty cycle
HR04
HR05
11.42 (24.20)
15.35 (32.52)
9.50 (20.10)
12.75 (27.02)
10.05 (21.30)
15.06 (31.90)
8.35 (17.70)
10.34 (21.90)
4.0 (5.5)
5.5 (7.5)
67
DOL (60Hz) and SD (50Hz)
Continuous Run, Automatic Stop/Start,
Reduced Energy Vent System
1450 (1760)
0 to 45 (32 to 113)
85 non-condensing
<6 (43)
<8 (46)
7.0 or 10.0 (102 or 145)
5.5 to 6.0 (80 to 87)
6.5 or 9.5 (94 or 138)
7.5 or 10.5 (109 or 152)
8.0 or 11.0 (116 or 160)
0 (bar) (1 = psi, 2 = kpa)
1.5 turns anti-clockwise
220
Fluid Force Red 2000 (Mineral) and HPO (Synthetic)
CC1118983
CZ77996
CC1054889
CZ77989
HR07
21.23 (45.00)
17.34 (36.75)
18.17 (38.50)
14.21 (30.10)
7.5 (10)
69
Direct
<10 (50)
60
90
0 = °C (1 = °F)
685 x 630 x 1078
3/4
15
0.3
2000
1850 (1089)
250
3
HR07RS
20.53 (42.50)
17.37 (36.80)
20.53 (42.50)
17.37 (36.80)
Inverter
Variable
1100 *-2150 *
0 to 40
(32 to 104)
7.0 (102)
7.0 (102)
7.5 (109)
8.0 (116)
230
CC1054890
CZ77990
CC1132751C