Introduction Introduction Model Range IMPORTANT ! BEFORE INITIAL START-UP, ENSURE THAT THE This Handbook relates to all ACE HV11 - HV22 vertical range COMPRESSOR IS FILLED WITH A HYDROVANE APPROVED compressors and hypac models. OIL. DO NOT OVERFILL. V11ACE08-4035S300 50Hz model...
To ensure the compressor operates safely you must carry out the specified maintenance procedures. The standard build of all Hydrovane products are designed to compress clean, dry, atmospheric air and are not intended for use Only approved oils should be used for flushing purposes.
Pressure injection - Obtain immediate medical attention, even if injury appears minor. Hydrovane declines all liability in the event of material damage or bodily injury resulting from negligence in the application of these Spillage - Soak up with absorbent clay.
Conditions or applications which prevent the compressor temperature stabilising between these parameters should be avoided. Consult your local Hydrovane Distributor if you have any particular concerns about operational characteristics of your compressor. High Operating Temperatures Some of the reasons for high compressor oil temperatures are: •...
Damage to mountings may occur if you attempt to slide the compressor into position. Model Weights Table 4.1 shows the weights for the ACE HV11-HV22 Fig. 4.1 - ACE HV11-22 Vertical Compressor compressors and the hypac range. Table 4.1 - Model Weights...
Positioning Your Compressor - Basic Requirements We recommend an approved installation from an authorized Hydrovane distributor with a service agreement to maintain your compressor. Position the compressor/hypac in a room of adequate size on a firm surface, level in both planes within five degrees of the horizontal.
Installation and Commissioning Electrical Installation (Fig. 5.2) Check Direction of Motor Rotation WARNING ! WARNING ! BEFORE STARTING WORK, ENSURE THAT THE READ HEALTH AND SAFETY PRECAUTIONS MAIN-LINE FUSES HAVE BEEN REMOVED FROM BEFORE STARTING COMPRESSOR. THE DISTRIBUTION BOARD. PRECAUTIONS Ensure that the compressor is filled with approved oil and that all SHOULD BE TAKEN TO PREVENT THEM BEING plugs are fitted securely.
An air drier is used to provide dry air (pressure dew point 3°C) for specialised applications. This User Manual covers the Hydrovane ACE HV11-HV22 vertical Where air demand fluctuates a compressor plus receiver is used range of compressors. The hypac range contains a compressor to store large quantities of air.
General Description Fig. 6.2 - Compressor Assembly Compressor Assembly (Fig. 6.2) The oil separator (S) located on the top ensures air delivered through the minimum pressure valve has an oil cleanliness of less than 3 ppm (parts per million by weight). The air is delivered The unit comprises of a vertical single stage, oil flooded, rotary, through the air delivery pipe (T) to the after cooler (E) before sliding vane compressor driven by an electric motor mounted to a...
Operating Instructions Operating Instructions Operating Instructions WARNING ! READ HEALTH AND SAFETY PRECAUTIONS BEFORE YOU START ANY SERVICE WORK. THE COMPRESSOR SHOULD ONLY BE OPERATED BY AUTHORISED PERSONS FULLY Fig. 7.1 - Controller Display TRAINED IN THE STARTING, STOPPING AND EMERGENCY STOP PROCEDURES.
Operating Instructions Press Plus Up/Minus Down buttons to scroll through available 7.1.6 Starting - Regulated Speed user menu codes P00 (view only). For variable speed models, the starting sequence is the same as Mo - Select Automatic or Manual Control that shown for single speed automatic mode except that, instead of the compressor continuing to run and pressure varying within Td –...
Operating Instructions Operational Display Symbols Motor running Power failure auto-restart (optional function) Loaded Remote load or remote pressure regulation active Amount of time, timer Remote start/stop Filter, differential pressure Normal operational mode: Selected item locked as temporary default display Pressure set point indication Menu mode: (upper &...
Adjustments Adjustments Compressor Control (Fig. 8.1) plus up/minus down to change the value to the desired pressure and press ENTER. The compressor controller has additional user menus, P01 for All items configured within menu P01 can be changed to suit the operation and P02 for error log recording.
USER WARNING Compressor pressure control adjustments should not be attempted by the user and must be carried out by a Hydrovane authorised service engineer. Failure to comply with this requirement may invalidate the compressor warranty. ST16135-00C...
After very long periods, it is recommended that the speed control unit capacitors and cooling fan(s) be replaced to ensure continued reliability of the unit. Refer to your Hydrovane Distributor for details. Fig. 9.1 - Oil Level Sight Glass Location...
Servicing Basic Service WARNING ! STOP THE COMPRESSOR AND ISOLATE IT FROM THE MAINS ELECTRICAL SUPPLY. LOCK THE ISOLATOR IN THE OFF POSITION. FIT A SAFETY NOTICE TO THE ISOLATOR ADVISING THAT WORK IS BEING CARRIED OUT ON THE COMPRESSOR. CLOSE THE AIR OUTLET VALVE TO ISOLATE THE COMPRESSOR FROM THE AIRLINE SYSTEM.
9.13 Clean Oil Cooler/Aftercooler (Fig. 9.4) WARNING ! Inspect the cooler matrix for signs of damage. If the matrix is damaged, consult your local Hydrovane Distributor. ISOLATE THE COMPRESSOR FROM THE MAINS ELECTRICAL SUPPLY. LOCK THE ISOLATOR IN The cooler matrix airflow is from the inside to outside; cleaning is THE OFF POSITION.
6 months, whichever is soonest. Tables 9.1 for 2000 hour oil change periods and 9.2 for 4000 hour oil change are shown in entirety, shaded items are Hydrovane Distributor maintenance tasks only. Note: Certain items may not be applicable to all units.
Page 29
Servicing Table 9.1 - Service Schedule Fluid Force Red, Clear and HPO (2000 hour change period) Every Every Every Maintenance Actions Install Daily Weekly 2000 4000 20000 Site-sufficient access for service Site–protected from weather Site–adequate ventilation Site–ambient temperature within limit Site–dust free ambient Check/torque electrical connections Check oil level filter at plug/sight glass...
Page 30
Servicing Table 9.2 - Service Schedule Fluid Force HPO (4000 hour change period) Every Every Maintenance Actions Install Daily Weekly 4000 hrs 20000 hrs Site-sufficient access for service Site–protected from weather Site–adequate ventilation Site–ambient temperature within limit Site–dust free ambient Check/torque electrical connections Check oil level filter at plug/sight glass Check correct drive rotation...
Motor fault (fault relay contact, overload device service level activities 1 and 2. These are reserved for use by fully contact or thermistor) trained Hydrovane authorised service engineers. Er 0115 E Delivery pressure sensor fault We strongly advise that no attempt is made to access these...
Parameters are set as factory defaults to match the inverter drive type and controlling features for variable speed operation. If, for any reason, you feel unsure about fault rectification, or any service aspect relating to your Hydrovane compressor, please contact your nearest Hydrovane Distributor. ST16135-00C...
Page 34
Technical Publications Department, CompAir UK Limited. CompAir UK Limited www.hydrovane.co.uk Claybrook Drive .hydrovane@compair.co.uk Washford Industrial Estate...
Need help?