EasySolar-II GX - Product Manual Table of Contents 1. Introduction ........................... 1 2. Safe Installation ........................2 2.1. Transport and storage ...................... 2 2.2. Grounding ........................2 3. Product Description ......................... 3 3.1. Features applying to all applications ..................3 3.1.1.
Page 3
EasySolar-II GX - Product Manual 8.6.8. Connection to the VRM Portal ................. 15 8.7. GX - How to update firmware .................... 15 8.7.1. Changelog ....................... 15 8.7.2. Via internet or with microSD-card/USB-stick ..............15 8.7.3. Direct download from the internet ................15 8.7.4.
EasySolar-II GX - Product Manual 1. Introduction The Victron EasySolar-II GX integrates the following elements: • A powerful MultiPlus-II inverter/charger • A SmartSolar MPPT solar charge controller • A GX device with a 2x 16 character display These elements come prewired, and preconfigured together inside a single unit.
EasySolar-II GX - Product Manual 2. Safe Installation Please read the documentation supplied with this product first, so that you are familiar with the safety signs and directions before using the product. This product is designed and tested in accordance with international standards. The product should be used for the designated application only.
EasySolar-II GX - Product Manual 3. Product Description The basis of the product is an extremely powerful sine inverter, battery charger and transfer switch in a compact casing. It is suited for use in Marine, Automotive, as well as stationary land-based applications.
EasySolar-II GX - Product Manual 3.1.11. External current transformer (option) External current transformer option to implement PowerControl and PowerAssist with external current sensing 3.1.12. Programmable analog/digital input/output ports (Aux in 1 and Aux in 2, see appendix) The product is equipped with 2 analog/digital input/output ports.
EasySolar-II GX - Product Manual The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the Storage mode float voltage is reduced to 2,2V/cell (13,2V for 12V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to 'equalize' the battery.
Page 9
EasySolar-II GX - Product Manual 1. Certification and CEC approval for off-grid use does NOT imply approval for grid-interactive installations. Additional certification to IEC 62109.2 and AS 4777.2.2015 are required before grid-interactive systems can be implemented. Please check the Clean Energy Council website for current approvals.
EasySolar-II GX - Product Manual 4. Operation 4.1. On/Off/Charger Only Switch The switch is located on the underside to the bottom right of the product. The switch has three positions. The centre position 0 is Off. The I position is On, and the II position is Charger Only.
EasySolar-II GX - Product Manual 5. GX LCD Interface The display screen will present useful information about your system. 5.1. On/off behaviour When the product is switched off with the physical switch on the device or with the Remote On/Off terminals, then the GX card is off as well.
In that case, the number of cells in series must be reduced. The MPPT component of the EasySolar-II GX is pre-programed to match the nominal battery voltage requirements of the included inverter/charger. Specific battery voltage charging parameters may need to be programmed in addition to the inverter/ charger voltage parameters.
EasySolar-II GX - Product Manual 7. Accessing Connection Points All electrical connections can be accessed by removing the bottom plate. See below photos of the 3K and 5K EasySolar-II GX with the bottom plate removed. Page 10 Accessing Connection Points...
8. Installation This product contains potentially dangerous voltages. It should only be installed under the supervision of a suitable qualified installer with the appropriate training, and subject to local requirements. Please contact Victron Energy for further information or necessary training 8.1.
EasySolar-II GX - Product Manual • Connect the battery cables. First the - cable then the +. Be aware that there may be a spark when making the battery connections. • Tighten the nuts to the prescribed torques for minimal contact resistance.
EasySolar-II GX - Product Manual 8.5. Connection of the AC cabling This product is a safety class I device, intended for a TN system (supplied with a ground terminal for safety purposes). Its AC input and/or output terminals must be provided with uninterruptible grounding for safety purposes.
EasySolar-II GX - Product Manual 8.6.1. Remote Control The product can be remotely controlled in two ways. • With an external switch (connection terminal M, see Appendix A). Operates only if the switch on the device is set to "on".
EasySolar-II GX - Product Manual Pre-requisites: see Section Voltage Sense 1. Note: the product is not suitable for 3-phase delta (Δ) configuration. 2. When the AS4777.2 grid code has been selected in VEConfigure, only 2 units in parallel per phase are allowed in a three phase system.
Page 19
EasySolar-II GX - Product Manual Step 3. Insert the device Note that you will see a warning “Not using media for storing logs”. That warning can safely be ignored. Step 4. Initiate the update Navigate to Settings → Firmware → Offline updates.
EasySolar-II GX - Product Manual 9. Configuration This section is intended mainly for stand-alone applications For grid connected Energy Storage Systems (ESS) please see https://www.victronenergy.com/live/ess:start • Settings may only be changed by a suitable qualified installer with the appropriate training, and subject to local requirements.
EasySolar-II GX - Product Manual 9.2. Explanation of settings Settings that are not self-explanatory are described briefly below. For further information, please refer to the help files in the software configuration programs. Inverter frequency Output frequency if no AC is present at the input.
EasySolar-II GX - Product Manual With this relay, the neutral conductor of the AC output is grounded to the chassis when the back feed safety relays are open. This ensures the correct operation of earth leakage circuit breakers in the output. If required an external ground relay can be connected (for a split-phase system with a separate autotransformer).
Windows laptop. Once completed, reconnect the VE.Direct cable that runs between the internal GX device and the Solar Charger. For the complete documentation for the MPPT included inside the EasySolar-II GX, please refer to these documents: SmartSolar MPPT 250/70 documentation...
EasySolar-II GX - Product Manual 10. Maintenance The product does not require specific maintenance. It will suffice to check all connections once a year. Avoid moisture and oil/soot/vapours, and keep the device clean. Page 21 Maintenance...
Turn the settings WeakAC and dynamic large (generally generator supply). current limiter on. The charger does not EasySolar-II GX is in 'Bulk protection' mode Check your batteries. NOTE: You can reset operate. 'Bulk thus, the maximum bulk charging time of 10 the error mode by switching off and back on Protection' shown.
The charging current Defective battery temperature sensor Disconnect the temperature sensor plug in drops to 0 as soon as the EasySolar-II GX. If charging functions the absorption phase correctly after approximately 1 minute, the initiates. temperature sensor should be replaced.
Page 27
4) Update the firmware in the last device that was switched on. Internal error. Should not occur. Switch all equipment off, and then on again. Contact Victron Energy if the problem persists. Page 24 Error Indications...
EasySolar-II GX - Product Manual 14. Appendix 14.1. Appendix A: Connection Overview Reference Description Connection Load connection. AC-OUT-1 Left to right: N (neutral), PE (earth/ground), L (phase) Load connection. AC-OUT-2 Left to right: N (neutral), PE (earth/ground), L (phase) AC input 1, AC input 2, AC Output...
EasySolar-II GX - Product Manual 14.5. Appendix E: Charge Characteristic 14.5.1. 4-stage charging: Bulk Entered when charger is started. Constant current is applied until nominal battery voltage is reached, depending on temperature and input voltage, after which constant power is applied up to the point where excessive gassing is starting (28.8 V resp.
EasySolar-II GX - Product Manual 14.6. Appendix F: Temperature Compensation Default output voltages for Float and Absorption are at 25 °C. Reduced Float voltage follows Float voltage and Raised Absorption voltage follows Absorption voltage. In adjust mode temperature compensation does not apply.