Victron energy SmartSolar MPPT 100/30 Manual

Victron energy SmartSolar MPPT 100/30 Manual

Charge controller
Hide thumbs Also See for SmartSolar MPPT 100/30:

Advertisement

SmartSolar charge controllers
MPPT 100/30
Manual
Handleiding
Manuel
Anleitung
Manual
Användarhandbok
MPPT 100/50

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartSolar MPPT 100/30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Victron energy SmartSolar MPPT 100/30

  • Page 1 Manual Handleiding Manuel Anleitung Manual Användarhandbok SmartSolar charge controllers MPPT 100/30 MPPT 100/50...
  • Page 3: General Description

    1. General Description 1.1 PV voltage up to 100V The charge controller is able to charge a lower nominal-voltage battery from a higher nominal voltage PV array. The controller will automatically adjust to a 12 or 24V nominal battery voltage. 1.2 Ultra-fast Maximum Power Point Tracking (MPPT) Especially in case of a clouded sky, when light intensity is changing continuously, an ultra fast MPPT controller will...
  • Page 4 1.8 Flexible charge algorithm Fully programmable charge algorithm, and eight preprogrammed algorithms, selectable with a rotary switch. 1.9 Adaptive three step charging The Controller is configured for a three step charging process: Bulk – Absorption – Float. 1.9.1. Bulk During this stage the controller delivers as much charge current as possible to rapidly recharge the batteries.
  • Page 5 1.11 Configuring and monitoring - Bluetooth Smart (built-in): connect to a smartphone or tablet running iOS or Android. - Use the VE.Direct to USB cable (ASS030530000) to connect to a PC, a smartphone with Android and USB On-The-Go support (requires additional USB OTG cable). - Use a VE.Direct to VE.Direct cable to connect to a MPPT Control, a Color Control panel or a Venus GX.
  • Page 6: Safety Instructions

    2. Safety instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that shall be followed during installation and maintenance. Danger of explosion from sparking Danger of electric shock Please read this manual carefully before the product is installed and put into use. This product is designed and tested in accordance with international standards.
  • Page 7: Installation

    3. Installation WARNING: DC (PV) INPUT NOT ISOLATED FROM BATTERY CIRCUIT. CAUTION: FOR PROPER TEMPERATURE COMPENSATION THE AMBIENT CONDITION FOR CHARGER AND BATTERY MUST BE WITHIN 5°C, 3.1. General Mount vertically on a non-flammable substrate, with the power terminals facing downwards. Mount close to the battery, but never directly above the battery (in order to prevent damage due to gassing of the battery).
  • Page 8 WARNING: WHEN A GROUND FAULT IS INDICATED, BATTERY TERMINALS AND CONNECTED CIRCUITS MAY BE UNGROUNDED AND HAZARDOUS. (also see the MPPT Excel sheet on 3.3 PV configuration our website) Provide a means to disconnect all current-carrying conductors of a photovoltaic power source from all other conductors in a building or other structure.
  • Page 9 3.5 Configuration of the controller Fully programmable charge algorithm (see the software page on our website) and eight preprogrammed charge algorithms, selectable with a rotary switch: Suggested battery type Absorption Float Equalize dV/dT mV/°C 31,8 Gel Victron long life (OPzV) 28,2 27,6 Gel exide A600 (OPzV)
  • Page 10 On all models with software version V 1.12 or higher a binary LED code helps determining the position of the rotary switch. After changing the position of the rotary switch, the LEDs will blink during 4 seconds as follows: Switch Blink position Bulk...
  • Page 11 3.7 Battery charging information The charge controller starts a new charge cycle every morning, when the sun starts shining. Default setting: The maximum duration of the absorption period is determined by the battery voltage measured just before the solar charger starts up in the morning: Battery voltage Vb (@start- Maximum absorption time...
  • Page 12 3.8 Automatic equalization Automatic equalization is default set to ‘OFF’. With the Victron Connect app (see sect 1.10) this setting can be configured with a number between 1 (every day) and 250 (once every 250 days). When automatic equalization is active, the absorption charge will be followed by a voltage limited constant current period.
  • Page 13: Troubleshooting

    4. Troubleshooting Problem Possible cause Solution Reversed PV connection Connect PV correctly Charger does not function Reverse battery Non replacable fuse blown. connection Return to VE for repair Check battery A bad battery connection connection Cable losses too high Use cables with larger cross section Large ambient Make sure that...
  • Page 14: Specifications

    5. Specifications SmartSolar Charge Controller MPPT 100/30 MPPT 100/50 Battery voltage 12/24V Auto Select Rated charge current Nominal PV power, 12V 1a,b) 440W 700W Nominal PV power, 24V 1a,b) 880W 1400W Maximum PV open circuit voltage 100V 100V Max. PV short circuit current 2) Maximum efficiency Self-consumption 10 mA...
  • Page 15 Figure 1: Power connections...

This manual is also suitable for:

Smartsolar mppt 100/50

Table of Contents