Mitsubishi Electric MELSERVO J5 Series User Manual page 40

Ac servo system
Hide thumbs Also See for MELSERVO J5 Series:
Table of Contents

Advertisement

MR-J5W_-_G
Inside of the display cover
(1)
(2)
No.
Name
(1)
Display section
(2)
Rotary switches (SW1/SW2)
(3)
DIP switch (SW3)
(4)
Network status LEDs
(5)
Main circuit power connector (CNP1)
(6)
Control circuit power connector (CNP2)
(7)
A-axis servo motor power connector
(CNP3A)
(8)
B-axis servo motor power connector
(CNP3B)
*1
(9)
C-axis servo motor power connector
(CNP3C)
(10)
Charge light
(11)
Protective earth (PE) terminal
(12)
Ethernet cable connector (CN1A)
(13)
Ethernet cable connector (CN1B)
(14)
USB communication connector (CN5)
3 STRUCTURE
38
3.1 Parts identification
RUN
(10)
(4)
MS
ERR
NS
SFTY
(5)
(3)
(22)
Side
(6)
(7)
(8)
(9)
(11)
Application
The 3-digit, 7-segment LED display shows the servo status and
alarm number.
Set the IP address of the servo amplifier.
Consists of the test operation switch and control axis deactivation
switch.
Displays each network status.
Connect the input power supply.
Connect the control circuit power supply and regenerative option.
Connect the A-axis servo motor.
Connect the B-axis servo motor.
Connect the C-axis servo motor.
When the main circuit is charged, this light is on. While the light is
on, do not change the connections of the wires.
Connect this terminal to the protective earth (PE) of the cabinet.
Connect the controller, servo amplifier or each network connected
device.
Connect with a personal computer.
(21)
Top
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
Detailed explanation
Page 40 Switch setting and
display of the servo amplifier
Refer to "Explanation of power
supply system" in the following
manual.
MR-J5 User's Manual
(Hardware)
Refer to "Explanation of power
supply system" in the following
manual.
MR-J5 User's Manual
(Hardware)
Page 44 CN1A/CN1B