Download Print this page
Sealey VS4021.V2 Manual

Sealey VS4021.V2 Manual

Vacuum tester & brake bleeding kit

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear protective
instructions
gloves
1. SAFETY
Keep this product in good working order and condition, take immediate action to repair or replace damaged parts.
9
Use approved parts only. Unapproved parts will invalidate the warranty.
9
Keep children and unauthorised persons away from the work area.
9
Keep work area clean and tidy and free from unrelated materials.
9
Ensure the work area has adequate lighting.
9
DO NOT use the kit to perform a task for which it is not designed.
8
DO NOT hold pump inlet against the skin whilst using the pump.
8
DO NOT allow untrained persons to use the kit.
8
DO NOT use whilst under the influence of drugs, alcohol or intoxicating medication.
8
After use, clean equipment and store in a cool, dry, childproof area.
9
WARNING! Brake fluid will damage paintwork. Any spillage should be flushed with water immediately.
WARNING! Brake fluid is flammable - keep away from sources of ignition, including hot surfaces e.g. exhaust manifold.
Dispose of waste liquids in accordance with local authority regulations.
9
WARNING! DO NOT pollute the environment by allowing uncontrolled discharge of fluids.
Always read and comply with the warnings on the brake fluid container.
9
Wear eye protection and keep skin contact to a minimum. If brake fluid enters eyes rinse with plenty of water and seek medical advice.
9
IMPORTANT: If swallowed seek medical advice immediately.
2. INTRODUCTION
Multi-function diagnostic tool used to test a variety of essential engine and associated functions including fuel, ignition, transmission and
emissions. Kit also includes reservoir, hoses and adaptors for bleeding brake and clutch systems on cars, commercials and motorcycles. Brass-
bodied vacuum pump features large, easy-to-read vacuum gauge calibrated in both inches and millimetres of mercury.
3. CONTENTS
ITEM
PART No.
1
VS402.V3-01
2A
VS402.V3-02A
RESERVOIR LID (FOR OPERATION)
2B
VS402.V3-02B
RESERVOIR LID (FOR TRANSPORT)
3
VS402.V3-03
4
VS402.V3-04
5
VS402.V3-05
6
VS402.V3-06
7
VS402.V3-07
8
VS402.V3-08
9
VS402.V3-09
BRAKE BLEED NIPPLE ADAPTOR
10
VS402.V3-10
© Jack Sealey Limited
VACUUM TESTER & BRAKE BLEEDING KIT
MODEL NO:
Wear eye
protection
DESCRIPTION
VACUUM PUMP WITH GAUGE
RESERVOIR JAR
560mm VACUUM HOSE
80mm VACUUM HOSE
HOSE ADAPTOR
HOSE ADAPTOR 'T-PIECE'
HOSE ADAPTOR 'STRAIGHT'
UNIVERSAL CUP ADAPTOR
Original Language Version
VS4021.V2
VS4021.V2 | Issue 2 (F,2,3) 26/02/19

Advertisement

loading

Summary of Contents for Sealey VS4021.V2

  • Page 1 VS4021.V2 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Operation

    CAUSE: Over lean or rich mixture. CAUSE: Blown cylinder head gasket to manufacturer’s specification. Check and reset in accordance with between two adjacent cylinders. Carry manufacturer’s specifications. out cylinder leakage test. Original Language Version VS4021.V2 | Issue 2 (F,2,3) 26/02/19 © Jack Sealey Limited...
  • Page 3 6.3.2. To test the fuel rail pressure, a gauge is attached to the rail, then engine loads must be created to vary engine manifold vacuum. Original Language Version VS4021.V2 | Issue 2 (F,2,3) 26/02/19 © Jack Sealey Limited...
  • Page 4 (fig.9) and start the engine. With a cold engine no reading should be noted. When the engine reaches normal operating temperature a manifold vacuum reading should be noted. fig.7 fig.8 fig.9 Original Language Version VS4021.V2 | Issue 2 (F,2,3) 26/02/19 © Jack Sealey Limited...
  • Page 5: Braking Systems

    Ensure that the vacuum pump is connected to the brake bleeder reservoir in accordance with the assembly diagram (fig.14). Failure fig.14 to do so will result in brake fluid being drawn into the vacuum pump. Original Language Version VS4021.V2 | Issue 2 (F,2,3) 26/02/19 © Jack Sealey Limited...
  • Page 6: Brake Bleeding Procedure

    Parts support is available for this product. Please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500 ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.