12. Adjust the boom bypass valve (Fig. 26) under the boom
control valve for the boom you turned off until the
pressure reading on the gauge is the same as it was in
step 9.
Figure 26
1. Boomy bypass valves
13. Turn the boom on.
14. Repeat steps 11 through 13 for the other booms.
15. Drive the sprayer at the desired speed while spraying
and turn each boom off individually. The pressure on
the gauge should not change much.

Operating the Sprayer

To operate the sprayer you first fill the spray tank, then
apply the solution to the work area, and finally clean the
tank. It is important that you complete all three of these
steps in succession to avoid damaging the sprayer. For
example, do not mix and add chemicals in the spray tank at
night and then spray in the morning. This would lead to
separation of the chemicals and possible damage to the
sprayer components.
Caution
Chemicals are hazardous and can cause personal
injury.
Read the directions on the chemical labels
before handling the chemicals and follow all
manufacturer recommendations and
precautions.
Keep chemicals away from your skin. Should
contact occur, wash the affected area thoroughly
with soap and clean water.
Wear goggles and any other protective
equipment recommended by the chemical
manufacturer.
1
Filling the Spray Tank
Important
Ensure that the chemicals you will be using
are compatible for use with Viton (see the manufacturer's
label; it should indicate if it is not compatible). Using a
chemical that is not compatible with Viton will degrade the
o-rings in the sprayer, causing leaks.
1. Stop the sprayer on a level surface, move the range
selector to the Neutral position, stop the engine, and set
the parking brake.
2. Determine the amount of water needed to mix the
amount of chemical you need as prescribed by the
chemical manufacturer.
3. Open the lid on the spray tank.
4. Add 3/4 of the required water to the spray tank using
the anti-siphon fill receptacle.
Important
Always use fresh clean water in the spray
tank. Do not pour concentrate into an empty tank.
5. Start the engine, press the accelerator pedal to the floor,
and set the neutral engine speed control to the On
position.
6. Set the pump switch to the On position.
7. Turn the agitation control valve to the 9 o'clock
position to start agitation in the tank.
8. Add the proper amount of chemical concentrate to the
tank, as directed by the chemical manufacturer.
Important
If you are using a wetable powder, mix the
powder with a a small amount of water to form a slurry
before adding it to the tank
9. Add the remaining water to the tank.
Applying Chemicals
Important
In order to ensure that your solution remains
well mixed, use the agitation feature whenever you have
solution in the tank. For agitation to work, the pump must
be on and the engine must be running above an idle. If you
stop the vehicle and need agitation on, place the range
selector in the Neutral position, set the parking brake, press
the accelerator pedal to the floor, and turn the neutral
engine speed control on.
Note: This procedure assumes that the pump is on from the
Filling the Spray Tank procedure.
1. Swing the booms into position.
2. Set the master boom switch to the Off position. The
Spray Pro monitor will display "HOLD."
3. Set the individual boom switches, as needed, to the On
positions.
4. Drive to the location where you will be spraying.