5.4.
Antibacterial deodorant control (Deodorizing fan control, Antibacterial
PC-LED control)
5.4.1.
ON/OFF control of Deodorizing fan
Press and hold the Hygiene Plus button for 0.5 second. "Hygiene Plus" indicator lights up and Antibacterial deodorant
control starts.
Press and hold the Hygiene Plus button for 0.5 second "Hygiene Plus" indicator lights off and Antibacterial deodorant
control stops.
ON/OFF of Deodorizing fan is controlled by ATC sensor, FCC sensor, PCC sensor and PC door open or close.
5.4.2.
Operation control of Deodorizing fan
1. Press and hold the Hygiene Plus button for 0.5 second.
First of all, it enters A mode that is rapid deodorization driving, the deodorizing fan drives for 120 minutes continu-
ously.
After starting B mode that is normal deodorization driving, the deodorizing fan control starts.
When compressor ON
When Compressor OFF
2. Press and hold the Hygiene Plus button for 0.5 second when antibacterial deodorant control starts.
When the antibacterial deodorant control stops (C mode), the deodorizing fan stops.
3. When power supply is turned on.
The deodorizing fan stops, even if A, B or C mode, when ATC is 34
4. When PC door open.
The deodorizing fan stop forcibly even if A, B or C mode, While PC door opens. (To be dewy prevention, frost preven-
tion)
5.4.3.
Antibacterial PC-LED control
1. Basic operation
n A or B mode of the deodorizing fan control, antibacterial PC-LED turn on while the deodorizing fan drives. (If the
fan stops, the LED is turned off.)
2. Exceptional control
In A or B mode of the deodorizing fan control, antibacterial PC-LED is turned on forcibly while PC door opens.
5.5.
Photosynthesis-freshness-improving effect control
Input: To press and hold the Vitamin-Safe button for 0.5 second.
Output: LED of VC (Green LED, Blue LED)
Content of processing: Press and hold the Vitamin-Safe button for 0.5 second, Vitamin-Safe indicator lights up and both
the blue LED and the green LED blink at the same time. It is operating a photosynthesis-freshness-improving effect con-
trol. While operating the control, press and hold the Vitamin-Safe button for 0.5 second, the control stops and "Vitamin-
Safe" indicator lights and LED of VC are turned off.
5.6.
FC Fan Control
FCDC Fan Motor (FC fan) operation is controlled, to prevent a trip of compressor when initial pull down, for making prop-
erly the temperature in the FC and the control of a power consumption increase.
Detection: ATC sensor
AT
When PC is cooled
When FC is cooled
Photosynthesis-freshness-improving
effect control
Blue LED
Green LED
10°C or below
11°C to 21°C
ON
ON
ON
ON
The fan drive
The fan drive
for 30 minutes
for 10 minutes
after compres-
after compres-
sor OFF
sor OFF
°C
or above and while FCC is 27
While operating the control
40Hz flashing
(ON/OFF: at each of 9.1msec)
18
22°C to 28°C
29°C or above
ON
ON
ON
ON
The fan OFF
The fan OFF
°C
or above.
While stop
OFF
OFF