ABB CP420 Installation And Operation Manual

ABB CP420 Installation And Operation Manual

Human machine interface (hmi) with a 4.7" stn liquid crystal display

Advertisement

Quick Links

CP420
Installation and Operation Manual
English
ABB, 1SBC159102M0201 2007-05

Advertisement

Table of Contents
loading

Summary of Contents for ABB CP420

  • Page 1 CP420 Installation and Operation Manual English ABB, 1SBC159102M0201 2007-05...
  • Page 2 Document number: ABB, 1SBC159102M0201 Please read the entire installation manual prior to installing and using this equipment. Only qualified personnel may install, operate or repair this equipment. ABB is not responsible for modified, altered or renovated equipment. Because the equipment has a wide range of applications, users must acquire the appropriate knowledge to use the equipment properly in their specific applications.
  • Page 3: Table Of Contents

    7 Operation ..................... 16 Self Test ..................16 System Menu ................17 Bench and Function Tests ............18 Setting Communication Parameters ........... 18 Downloading an Application ............. 19 Uploading an Application ............20 Copying an Application ............. 22 Passwords................... 23 ABB, 1SBC159102M0201...
  • Page 4 Contents ABB, 1SBC159102M0201...
  • Page 5: Safety Precautions

    – The supplier neither guarantees that the operator terminal is suitable for your particular application, nor assumes responsibility for your product design, in- stallation or operation. ABB, 1SBC159102M0201...
  • Page 6 Dismantling and Scrapping – The operator terminal or parts thereof shall be recycled according to local regulations. – The following components contain substances that might be hazardous to health and the environment: lithium battery, electrolytic capacitor and display. ABB, 1SBC159102M0201...
  • Page 7: Installation

    Installation Installation Package Contents The following parts are found in the box: – Operator terminal CP420 – 4 installation fasteners – Power connector (connected to the 24 V DC power outlet) – This installation and operation manual (1SBC159102M0201) ABB, 1SBC159102M0201...
  • Page 8: Product Specifications

    Product Specifications Product Specifications Parameter CP420 Front panel, W x H x D 170.3 x 102.6 x 4.2 mm Mounting depth 44.6 mm Cut-out dimensions 160.7 x 93.0 mm Front panel protection IP 65/NEMA 4 Weight 0.47 kg COM1 9-pin female connector: RS232/RS485...
  • Page 9: Description Of Parts

    Product Specifications Description of Parts Front Fixture mounting holes Power lamp Communication lamps Display Back DIP switches (1-10) DC power outlet COM1: RS232/RS485 COM2: RS422/RS485 ABB, 1SBC159102M0201...
  • Page 10: External And Cut-Out Dimensions

    Product Specifications External and Cut-out Dimensions +0.5 Unit: mm 160.7 -0.1 160.4 CUTOUT DIMENSION 44.6 170.3 Mounting Procedure 1. Cut out the control front panel to match the dimensions (mm) below. ABB, 1SBC159102M0201...
  • Page 11: Grounding

    3. The operator terminal is to be installed within the angle of 0 to 135 shown below. Grounding To make sure that the operator terminal works properly and to prevent it from radiating radio frequency noise, it must be connected to the earth ground. ABB, 1SBC159102M0201...
  • Page 12: Power Supply And Wiring

    Product Specifications Power Supply and Wiring CP420 must use the power supply with 24 V DC and the power consumption is 12W. Warning: To avoid an electrical shock, be sure to switch off the power before connecting the communication/download cable to the operator terminal.
  • Page 13: Dip Switches

    The default user level is set to 9 if the operator terminal requires no password to start its operation. Reserved SW10 COM2 Port For RS485, this switch has to be set ON. For RS422, this switch has to be set OFF. ABB, 1SBC159102M0201...
  • Page 14: Communication Ports

    Switches. Function Function RS485+ RS422 TX+ (RS485+) RS232 RXD RS422 CTS+ RS232 TXD RS422 CTS- RS422 RX+ Signal ground Signal ground RS485- RS422 TX- (RS485-) RS232 RTS RS422 RTS+ RS232 CTS RS422 RTS- Optional; RS422 RX- +5V@100mA output ABB, 1SBC159102M0201...
  • Page 15: Lcd Contrast Adjustment

    Set, and performing the following steps: 1. Touch the upper-left and lower-right corners of the screen. 2. Follow the route on the screen. 3. Touch the square on the center of the screen to complete the task. See also section 7.2 System Menu. ABB, 1SBC159102M0201...
  • Page 16: Operation

    After downloading again, all items should pass the self-test. Note: When using the operator terminal for the first time, remember to reset the real time clock (RTC). ABB, 1SBC159102M0201...
  • Page 17: System Menu

    + and - to set the value of the field. F3 - Copy Copies application data to another CP420. F4 - Set Adjusts touch panel LCD contrast. See also section 6 LCD Contrast Adjustment.
  • Page 18: Bench And Function Tests

    Bench and Function Tests Set dip switches SW3 and SW4 = OFF to be able to run the bench and function tests for the CP420. Turn on the operator terminal to display the following screen: The bench test performs an overall hardware test, and the function test lets the user select which item to be tested.
  • Page 19: Downloading An Application

    Operation Downloading an Application Connect the RS232 port on the PC to the COM1 port on the CP420 using a TK401 cable. The connection can also be made according to the illustration be- low. 9-pin male 9-pin female RXD 2...
  • Page 20: Uploading An Application

    Then the operator terminal will prompt for a password: enter the password set in CP400Soft from Application/Workstation Setup. Once the correct password is entered, the operator terminal starts to upload the application to the PC. For information about setting a password, please see section Passwords. ABB, 1SBC159102M0201...
  • Page 21 *.V6F file. Thus a source file can serve the purposes of maintenance and modification. Note: When uploading for the first time, make sure to first run the application once, or else the upload function will not work. ABB, 1SBC159102M0201...
  • Page 22: Copying An Application

    Operation Copying an Application To copy an application from one CP420 to another CP420, select Copy from the system menu. Set the dip switch SW7 = ON and connect the two operator terminals with a download cable. After the self-test, the system menu will be dis- played on the screen.
  • Page 23: Passwords

    2. User level 1 has the highest privilege and User level 9 has the lowest. Note: Only users of User Level 1 has the right of access to the password table. ABB, 1SBC159102M0201...
  • Page 24 When selecting F3 - Copy in the system menu or File/Upload Application in CP400Soft, the operator terminal will prompt for a password. The user will need to enter the correct password to copy an application from one CP420 to another. Note that setting this password is different from the passwords set in Scenarios 1-3.
  • Page 25 ABB FRANCE ABB STOTZ-KONTAKT GmbH Division Automation Products Po Box 10 16 80 Export Department 69006 Heidelberg 10 rue Ampère Germany 69685 Chassieu Tel. : +49 (0) 6221/701-1190 France Fax. : +49 (0) 6221/701-1333 Tel. : +33 (0) 4 72 22 17 22 Fax.

Table of Contents