4. Direct connection by emulated serialization on parallel DIO

4. Direct connection by emulated serialization on parallel DIO

The robot controller's parallel input data can be transferred to the serial output data
regardless of the robot program. Likewise, the robot controller's serial input data can be
transferred to the parallel output data. By using this function, a sensor or relay connected
to the parallel I/O of the robot controller can be used like a device connected to the CC-
Link master module.
Chapter
3
CC-Link Master station PLC
n
NOTE
When the directly connected and set output port is used with the program, the
bit information may not become the intended value. Do not use the directly
connected and set output port with the program.
4.1

Emulated serialization setting on parallel DIO

The relation of the parallel port and serial port that can be connected is shown below.
Input device such as sensor
DI port → SO port
DI2()
DI3()
DI4()
DI5()
[Operation]
1. Press the
SYSTEM>OPTION>SIO               V8.01
  1.Direct SI2() −> DO2()     NO  
  2.Direct SI3() −> DO3()     NO  
  3.Direct SI4() −> DO4()     NO  
  4.Direct SI5() −> DO5()     NO  
  5.Direct SO2() <− DI2()     NO  
 EDIT    JUMP  
3-8
Output
Input
CC-Link connection
Output device such as valve
SO2()
DO2()
SO3()
DO3()
SO4()
DO4()
SO5()
DO5()
(SIO) key in "SYSTEM > OPTION" mode.
F 3
Robot controller
SI         DO
SO        DI
Parallel I/O connection
DO port ← SI port
SI2()
SI3()
SI4()
SI5()
Relay, valve, etc.
Sensor, etc.