Toshiba TOSVERT VF-MB1 Function Manual page 31

Hide thumbs Also See for TOSVERT VF-MB1:
Table of Contents

Advertisement

10 Run/Stop
11 Coast stop
12 Emergency off
13 Fault reset
14 Frequency priority
15 Command priority
(*1): When set "12(sr0)" to fmod, preset speed operation frequency 0 is selected.
(*2): The V/f switching ORs with Bit 10 of [fa23].
(*3): The Acc/Dec switching ORs with Bit 8 of [fa23]
fa23 (Communication command 2)
7.5.2.
VF-MB1/S15
bit
Function
0
(Reserved)
Electric power quantity
1
reset
2
(Reserved)
3
(Reserved)
4
(Reserved)
5
(Reserved)
6
(Reserved)
Maximum deceleration
7
forced stop
Acceleration/decele-
8
ration selection 1
Acceleration/decele-
9
ration selection 2
10
(Reserved)
11
(Reserved)
12
OC stall level switch
13
(Reserved)
14
(Reserved)
15
(Reserved)
Note: Set 0 to reserved bit.
VF-AS3
bit
Function
0
Control switching
Electric power quantity
1
reset
2
(Reserved)
3
Braking request (BC)
4
Preliminary excitation
5
(Reserved) (*3)
6
Braking answer (BA)
7
Quick deceleration 2
8
Acc/dec switching 1 (*1)
9
Acc/dec switching 2
10 V/f switching 1 (*2)
Stop
Standby
Cost stop
OFF
Emergency off Always enable, [E] trip
OFF
OFF
Enabled
OFF
Enabled
0
-
OFF
-
-
-
-
-
Normal
Enabled
00: Acceleration/deceleration 1
01: Acceleration/deceleration 2
10: Acceleration/deceleration 3
-
-
OC stall 1
OC stall 2
-
-
-
0
Speed control
Torque control
OFF
Reset
-
-
Normal
Forcibly braked
Normal
Enabled
-
-
Brake applied
Brake released
Normal
Enabled
00: AD mode 1
01: AD mode 2
10: AD mode 3
11: AD mode 4
00: V/f 1
01: V/f 2
10: V/f 3
- 29 -
Run
-
-
Reset
Trip reset
Enabled regardless of the setting of
fmod
Enabled regardless of the setting of
cmod
1
-
Electric power quantity (fe76,
Reset
fe77) reset
-
-
-
-
-
Select acceleration/deceleration 1-4
by combination of two bits.
AD1: acc, dec
AD2: f500, f501
AD3: f510, f511
-
-
OC stall 1: f601
OC stall 2: f185
-
-
-
1
-
Electric power quantity (fe76,
fe77) reset
-
-
-
-
-
-
Select Acc/Dec mode 1 - 4 by
combination of two bits.
AD mode 1: acc, dec
AD mode 2: f500. f501
AD mode 3: f510, f511
AD mode 4: f514, f515
Select V/f pattern 1 - 4 by combination
of two bits
V/f 1: pt = setting value, vl, vlv,
E6581738④
Note
-
-
-
-
-
-
-
-
-
-
-
-
Note

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tosvert vf-s15Tosvert vf-as3

Table of Contents