Toshiba TOSVERT VF-MB1 Function Manual page 16

Hide thumbs Also See for TOSVERT VF-MB1:
Table of Contents

Advertisement

ZSW Status Word Data
Bit
Value
1
Ready To Switch-on
0
0
Not Ready To Switch-on
1
Ready To Operate
1
0
Not Ready To Operate
1
Operation Enabled
2
0
Operation Disabled
1
3
0
1
Coast Stop Not Activated
4
0
Coast Stop Activated (OFF 2) "Coast Stop (OFF 2)" command is present.
1
Quick Stop Not Activated
5
0
Quick Stop Activated (OFF 3) "Quick Stop (OFF 3)" command is present
1
Switching On Inhibited
6
0
Switching On Not Inhibited
1
Warning Present
7
0
1
Within Tolerance Range
8
0
Out Of Tolerance Range
1
Control Requested
9
0
No Control Requested
1
f Or n Reached Or Exceeded
10
0
f Or n Not Reached
(VF-MB1/S15)
Factory specific bit
11
----
(VF-AS3)
FP terminal monitor
(VF-MB1/S15)
Factory specific bit
12
----
(VF-AS3)
FL terminal monitor
(VF-MB1/S15)
Factory specific bit
13
----
(VF-AS3)
R1 terminal monitor
(VF-MB1/S15)
(Reserved)
14
----
(VF-AS3)
R2 terminal monitor
(VF-MB1/S15)
(Reserved)
15
----
(VF-AS3)
DQ11 terminal monitor
Note: The bit described "(Reserved) and "Factory specific bit" are unstable. Don't use the bit for
the judgment.
Name
Power supply is switched on
Refer to control word, bit 1.
Drive follows setpoint.
(Refer to control word 1, bit 3)
Fault Present
VF-MB1/S15/AS3 tripped.
No Fault
VF-MB1/S15/AS3 is not tripped.
Control word bit1 or 2 is set to 0
or fault trip has been acknowledged.
Drive still operational: Alarm in service parameter:
No acknowledgement.
No Warning
Alarm not present or alarm has disappeared again
Speed Error
Refer to section 6.2.1.
Speed Error
VF-MB1/S15/AS3
master.
VF-MB1/S15/AS3 is controlled by another interface.
Actual value ≥ Comparison value (setpoint)
(VF-MB1/S15)
Factory specific bit
(VF-AS3)
FP output terminal monitor
(VF-MB1/S15)
Factory specific bit
(VF-AS3)
FL output terminal monitor
(VF-MB1/S15)
Factory specific bit
(VF-AS3)
R1 output terminal monitor
(VF-MB1/S15)
(Reserved)
(VF-AS3)
R2 output terminal monitor
(VF-MB1/S15)
(Reserved)
(VF-AS3)
DQ11 output terminal monitor
- 14 -
E6581738④
Note
-
-
-
-
-
-
is
controlled
by
PROFIBUS
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tosvert vf-s15Tosvert vf-as3

Table of Contents