• Burst (external)
Multiple images are acquired per trigger and the first symbol detected among the images is decoded.
The number of image to be acquired and the interval between each image acquisition can be set. Additionally, this trigger
mode supports a timeout setting.
A timeout setting value is set to read for each acquired image, not for the whole burst.
• Self (internal)
Codes are read by acquiring images at the set interval configured in "Interval" without external trigger inputs. Additionally, the
timeout time is equivalent to the value of the set "Interval" in this trigger mode.
Some parameters can be configured to set standby time until the next code is read, and whether the code reader reads the
same code repeatedly.
This trigger mode does not support automatic exposure.