Procedure
Step 1 According to the actual cable route, cut the PGND cable into a proper length to prepare an
RRU PGND cable. Then add an OT terminal at each end of the cable according to the
instructions in Assembling the OT Terminal and the Power Cable.
Step 2 Install the RRU PGND cable.
Connect the M6 OT terminal at one end of the PGND cable to the ground terminal at the RRU
bottom and the M8 OT terminal at the other end to the external ground bar, as shown in
Figure
Figure 9-12 Installing an RRU PGND cable
Figure 9-13 Correct position of an OT terminal
Step 3 Label the installed cables according to the instructions in Attaching a Cable-Tying Label.
----End