Advertisement

Testing FRESH/RECIRC air changeover

Place the machine on a level ground, lower the work equipment to the ground and stop the engine.
Testing
(PC88MR-K5D2-360-K-00-A)
FRESH/RECIRC air is selected by changing the FRESH/RECIRC air changeover door (damper) angle in the
air conditioner unit with the FRESH/RECIRC air changeover servo motor. Check the opening and closing
operation of the door visually.
a The system does not have self-diagnosis function for FRESH/RECIRC air changeover servo motor.
1. Open cover (1) and remove outside air filter (2).
2. Start the engine and turn on the air conditioner power.
3. Press FRESH/RECIRC air selector switch on the machine monitor's air conditioner control screen, and
then check the opening and closing operation of FRESH/RECIRC air changeover door (4) by using mirror
(3).
a As the connector for FRESH/RECIRC air changeover servo motor is located on the floor of the air
conditioner unit, its connection condition cannot be checked.
PC88MR-10

Testing FRESH/RECIRC air changeover

(ALL-K5D2-001-K-00-A)
80 Appendix
80-43