CONDITIONS OF WARRANTY Your AGA Solid Fuel Stove is guaranteed against any part that fails (under normal operating conditions) as detailed in the following table with timelines specified from the date of installation of the appliance. If the unit is not installed with- in six months of date of purchase, the warranty will commence six months from the date of purchase.
INSTALLATION CHECK LIST Tick Flue System 1. Minimum Flue Height of 4.6 metres (15 feet). 2. Appliance should be connected to a 125mm (5”) diameter flue pipe throughout 3. The horizontal flue run should not exceed 150mm (6”) 4. All flue pipework passing through walls must be sleeved & adequately insulated in line with current Building Regulations.
IMPORTANT OPERATION / MAINTENANCE NOTES Now that your AGA Solid Fuel Stove is installed and no doubt you are looking forward to the many comforts it will provide, we would like to give you some tips on how to get the best results from your stove.
Please refer to the current standards, BS EN 15287- GENERAL 1:2007 Design, Installation and Commissioning of When installing, operating and maintaining your chimneys. BS EN 14336:2004: Heating Systems in AGA Stove respect basic standards of fire safety. Buildings. Installation & Commissioning of Water Read these instructions...
All register plates, restrictor plates, damper etc., The stove comes partially configured for top outlet which could obstruct the flue at a future date should and requires the flue spigot (supplied in the firebox) be removed before connecting this appliance. to be fitted to the top outlet flue connection as shown in Fig 3 using the nuts &...
VENTILATION & COMBUSTION AIR REQUIRE- Fig.4 MENTS It is imperative that there is sufficient air supply to the stove in order to support correct combustion. The air supply to this appliance must comply with current Building Regulations Part J, Heat Providing Appliances.
If there is an extraction fan fitted in adjacent rooms EXTERNAL DUCTED AIR where this appliance is fitted, additional air vents may be required to alleviate the possibility of An outside air kit which will allow for the air supply spillage of products of combustion from the for the stove to be ducted from outside and is avail- appliance/flue while the fan is in operation.
FLOOR PROTECTION There are several conditions to be considered in When installing this heater, it is required to be selecting a location for your AGA Stove. installed on a CONSTRUCTIONAL HEARTH – see Building Regulations document J for guidance. a. Position in the area to be heated, central locations are usually best.
STOVE DIMENSIONS Fig.9 COMMISSIONING AND HANDOVER OPERATION On completion of the installation allow a suitable period of time for any fire cement and mortar to dry Check that all dampers and catches are operating out, when a small fire may be lit and checked to correctly and ensure that all flue connections are ensure the smoke and fumes are taken from the thoroughly sealed.
RECOMMENDED FUELS This stove has obtained HETAS Ltd approval for burning natural and manufactured smokeless fuels All fuels should be stored under cover and kept only as detailed in recommended fuels below. as dry as possible prior to use. HETAS Approval does not cover the use of other fuels either alone or mixed with the recommended This appliance has been tested using seasoned fuels listed, nor does it cover instructions for the use...
LIGHTING THE STOVE SLOW BURNING NOTE: When operating stove, recommended to use the Glove provided to Slow burning will cause the window glass to blacken open the fire door as the door handle will and can craze the glass this should not be used become hot.
PERIODIC MAINTENANCE MONTHLY MAINTENANCE Adjusting the Door Catch Cleaning Stove Flue Pathways Over time, the fire door latch can loosen due to the It is recommended that the flue pathways in the continual compression and hardening of the rope stove are cleaned on a monthly basis (or less seal between the door and the front casting.
GLASS REPLACEMENT Open the door fully. Remove the four fixing screws and clips (see Fig 14). Clean the glass recess in the door. Replace the adhesive thermal tape on the back face of the door if damaged. Fit the glass in position and replace the four corner clips &...
19. GRATE - W5 CAST GRATE ASSY 20. REFRACTORY BRICK GUIDE - SIDE BOARD GUIDE With AGA Rangemaster’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to AGA Rangemaster the appliance described and illustrated at...
Page 17
BS EN 13240 Standard AGA Rangemaster Ellesmere EC5W This stove has an Efficiency Rating of “A” and has passed the Eco-design 2022 Standard and has the met the Emissions Standards as defined by DEFRA for Burning Wood in Smoke Free Areas...
Need help?
Do you have a question about the Ellesmere EC5W and is the answer not in the manual?
Questions and answers