Page 1
Ellesmere ECG Standard ECG Model Balanced Flue Gas Stove Natural Gas INSTALLATION, SERVICING AND USER OPERATING INSTRUCTIONS For use in GB & IE (United Kingdom and Ireland) Document No. : RH/MM/SIN/BUR – Iss 02 Dated 19/12/2019 File: Ellesmere Gas EC5 MM_User_Man.doc...
Page 2
Rear Chain kit is fitted – full instructions in this stove Flue locking screws x2 fitted into the flue collar The stove is installed, commissioned & operated as stated in this manual AGA Ellesmere Standard Gas Stove...
“A” European Energy Label Rating (EEL Eco Labelling) Who Can Fit My New AGA Gas Stove: Before the Gas Engineer can commence working on this stove they must be Gas Safe - qualified and registered for Natural Gas to install, commission and service this stove to the...
AGA Flue Kits 1 & 2 – Top Exit AGA Flue Kits 3 – Rear Exit - Snorkel AGA Flue Kits 4 – Renovation Kit for Existing Chimney Fitting the Batteries into the External Power Pack Fuel Bed Arrangements – Step By Step Log Layout Commissioning the Appliance ...
GB & IE 1. General Notes This AGA Stoves gas appliance is a High Efficiency, Balanced Flue Log Fuel Effect appliance. It provides radiant and convectional heat using the latest burner technology, as well as having a variable heat output.
This will then allow the paint the opportunity to fully cure. During this period it is possible for some fumes and vapours to be given off. We would recommend keeping children and pets out of the area at this time. AGA Ellesmere Standard Gas Stove...
150.mm outer collar of the 2 piece flue collar AGA Ellesmere Standard Gas Stove...
Page 8
Refer to full instructions on previous page Picture showing the stove from the top view with the support chain fitted to a distance of 350mm. This is the minimum distance to a combustible wall AGA Ellesmere Standard Gas Stove...
Clip the snap hook onto the eye bolt in the wall insuring the chain is at the right length so it is straight but not over tight but not loose Now this chain is fitted it will prevent the stove tipping forward when front door is open AGA Ellesmere Standard Gas Stove...
Pictures of the Handset Remote Controller and rear picture showing how the battery is fitted The 9v battery is supplied fitted inside the remote controller AGA Ellesmere Standard Gas Stove...
Which are fitted into the rear removable Battery pack NOTICE Only the AGA approved - AC Mains Adapter can be used. Use of other adaptors can render the system inoperable and cause permanent damage which is not covered by the warranty 2.3.2 Remote Control...
Page 12
(small flame button) to set appliance at pilot flame Quick Approach to Setting the Stove into LOW Flame mode Double-click (small flame) button. “LO” will be displayed. Note: Flame goes to high fire first before going to designated low fire. AGA Ellesmere Standard Gas Stove...
Page 13
The flame height is then automatically adjusted to achieve the Daytime set Temperature Setting the ON/OFF “Daytime” temperature Briefly press the SET button to scroll to TEMP ( SUN LOGO) mode Hold the SET button until the TEMP flashes AGA Ellesmere Standard Gas Stove...
Page 14
Hold the set button until the Temperature flashes Press (large flame) button to increase night time setback Temperature Press the (small flame Logo) button to decrease night time setback Temperature Press OFF or simply wait to complete programming AGA Ellesmere Standard Gas Stove...
Page 15
The ON/OFF times have to be programmed in the order P1 If P1 = P1 or P2 = P2 the timer is deactivated To have the fire over night, it can be set: 23:50 and P1 0:00 AGA Ellesmere Standard Gas Stove...
Page 16
Set the minutes by pressing the (small flame) button Setting P1 off time Briefly press SET button to scroll to setting P1 OFF time. P1 and (moon) are dis- played and the time flashes Set the hour by pressing the (large flame) button AGA Ellesmere Standard Gas Stove...
Annual Service For the AGA Warranty to be valid this stove must be services once a year by a Gas Safe Qualified Engineer. After an annual service on this stove please complete the record sheet at the rear of the...
Note: This is a one time setting only, and is not required after changing the batteries in the remote handset or battery pack AGA Ellesmere Standard Gas Stove...
The log set is in a cardboard box fitted to the rear of the stove and protected by the transport pallet ITEM A ITEM B ITEM E ITEM D ITEM F ITEM C You have to purchase the AGA flue kit separately please refer to the Flue Kits AGA Ellesmere Standard Gas Stove...
A minimal gap of 100mm should be left all round the appliance to non-combustible materials. For minimum clearance to combustible materials see table overleaf – However any installation must be in accordance with the latest Local Building Regulations AGA Ellesmere Standard Gas Stove...
If a shelf is to be fitted above the fireplace opening, a gap (as defined by local building Regulations must be adhered to) should be left between the opening and the shelf. AGA Ellesmere Standard Gas Stove...
Page 22
Please ensure this Dial is fully turned to the ON position. If not the remote will not work. When turning to the ON position you will hear a click to confirm it is locked in the ON position. AGA Ellesmere Standard Gas Stove...
Page 23
Please make sure any fingerprints are wiped off the inside and the outside of the glass otherwise they will mark the glass permanently When the stove is first lit the glass will form condensation on the inside and that will clear after about two minutes AGA Ellesmere Standard Gas Stove...
The flue system must be constructed from the appliance vertically upwards from the top of the stove or horizontally out of the rear of the stove, with all joints being fully locked and sealed using the AGA Stoves specified parts.
Page 25
9 – Refit the parts as per the following steps in reverse for the above make sure the firebox is air tight on all of the seals for the 2 x flue collars and front glass AGA Ellesmere Standard Gas Stove...
Page 26
Please note the stove is supplied with the air inlet and exhaust outlet blanking plates fitted to the rear of the stove. So the 2 x flue collars (supplied loose) would be fitted to the top of the stove for a vertical flue kit to be installed AGA Ellesmere Standard Gas Stove...
Page 27
If the outer wall surface is constructed of combustible material, a non-combustible plate should be fitted behind the terminal projecting 25mm beyond the external edges of the terminal. AGA Ellesmere Standard Gas Stove...
Above intersection with roof A* In addition, the terminal should not be nearer than 300mm to an opening in the building fabric formed for the purpose of accommodating a built in element such as a window frame. AGA Ellesmere Standard Gas Stove...
Page 29
& painted black in line with the finish on the stoves All of the AGA Ellesmere balanced flue gas stoves are fitted with flue collars to fit the Poujoulat 100/150 Duo gas system. Please do not attempt to fit other concentric flue pipes to this flue collar as they will not be a perfect gas tight match.
Page 30
All Diagrams for illustration purposes only - Not to Scale To Order Flue kits please email Spares@agastoves.org.uk or ring Poujoulat on 01483 461700 AGA Ellesmere Standard Gas Stove...
Page 31
GB & IE AGA Flue Kit 3 – Rear Exit Please Note – The Maximum length of the Horizontal flue is 500mm as per the drawing above Diagram for illustration purposes only - Not to Scale Flue Kit 3 – Consists of the following: ...
Page 32
Register Plate This kit will allow you to install your Ellesmere Balanced gas flue stove into an existing fireplace and use your existing chimney – please note your chimney must be in a good condition for this system to be...
Page 33
4 x AA batteries replace the screw and lid correctly and reconnect AGA Ellesmere Standard Gas Stove...
Please note – If the logs are not laid as per the instructions the overall efficiency performance and flame pattern of this stove will be greatly effected. If additional or Non approved AGA Logs are added to this stove it will void your warranty...
Page 35
GB & IE 3.6.1 ECG Ellesmere Gas Stove – Log Layouts Scatter the bags of Embers over the top of the burners as shown, keeping the pilot area clear as marked in the white circle Pilot and Cross Over Light area must...
Page 36
Position Ceramic Log 5 so it sits in the middle of Log 2 and Log 4. But make sure it is not too close to the thermocouple and pilot light guard as this can prevent the lighting of the stove AGA Ellesmere Standard Gas Stove...
Outlet Pressure Tap. When opening these test points the room must be well ventilated and no naked flames or sparks are to be near the stove. You must fully leak test the valve after commissioning AGA Ellesmere Standard Gas Stove...
Heat shield pocket – be careful not to pull any wires out of their multi-plug sockets as shown in the white circles Pictures shows receiver unit with the Battery lead jack plug fitted – see white circle Picture 3 – Showing the receiver unit fully fitted into the Heat Proof pocket holder AGA Ellesmere Standard Gas Stove...
Turn the appliance OFF and isolate the gas supply. Ensure the appliance is fully cold before attempting to start servicing the appliance. No liability can be accepted by AGA Stoves for injury caused by burning or scolding by a hot appliance.
Pilot 446.1385.44 Efficiency Class Nox Class Using the AGA Mertik GV60 valve and G9R Remote Maximum High Heat Output 4.37 kW This CE plate is found at the back of the stove at the bottom The Aluminium serial plate for the stove is found if you open the front door and it is on the left hand side above the bottom hinge mount.
Page 41
GB & IE 5.1 Exploded View AGA Ellesmere Standard Gas Stove...
70007 Complete Burner Assembly LPG 70016 Pilot Assembly Natural Gas 70008 Complete Burner Assembly Natural 70017 GV60 Wiring Loom 70009 AGA Approved Mains Adapter 70018 Battery Box 70019 500mm 12v Extension Lead for Battery box AGA Ellesmere Standard Gas Stove...
Please refer to Appendix 1 & 2 overleaf It is also a condition of the Warranty that your AGA Stove is regularly serviced (every 12 months) by a suitably trained and qualified individual, Gas Safe registered in the United Kingdom (or equivalent in other countries).
Page 44
The liability on these issues is covered by AGA Stoves Terms and Conditions of Sale. AGA Stoves’ total liability extends only to the purchase price paid for the goods by the Premium Retailer, The AGA Stoves Warranty does not affect your statutory rights.
Customer has no issues with the stove? SECTION 5 - CUSTOMER SIGN OFF GAS SAFE ENGINEER SIGN OFF Customer Name: Gas Safe Engineer Full Name: Gas Safe Engineer Signature: Customer Signature: Date: Gas Safe Engineer Registration Number: Date: AGA Ellesmere Standard Gas Stove...
Glass Seal Replaced on Inner Glass YES or NO – YES or NO – YES or NO – please circle which one please circle which one please circle which one Other Notes Other Notes Other Notes AGA Ellesmere Standard Gas Stove...
AGA Rangemaster Station Road, Ketley Telford, Shropshire TF1 5AQ United Kingdom www.agastoves.co.uk 4,37 This Stove is Manufactured in the UK AGA Ellesmere Standard Gas Stove...
Need help?
Do you have a question about the Ellesmere and is the answer not in the manual?
Questions and answers