Panasonic U-8ME1E8E Service Manual page 14

2way system
Table of Contents

Advertisement

3. Compressor Control
Evaporation temperature area
5.5
Te_tgt_max.
5.0
Te_tgt_min.
2.0
1.5
*The evaporation temperature area changes depending on the maximum required level of each indoor unit as
shown in the right figure.
*C area is regarded as B area for 6 minutes after compressor starts.
*When the system operates in a minimum capacity, the system will continue operating for at least 6 minutes if the
evaporation temperature area is C area.
*The evaporation temperature is not adjusted while specially controlling defrosting and the oil recovery, etc.
*The evaporation temperature is not adjusted when there are one or more indoor units that select the test run.
If one or more indoor units are selected into test run, the system doesn't stop in all states except alarm appearing.
*The test run will finish automatically in about one hour.
Area shift function
B area is able to shift by EEPROM setting of outdoor unit.
EEPROM setting in main outdoor unit
Lower temperature of B area
CODE: 3F
Setting No
-9
-8
-1
0 (factory preset mode)
1
9
C area shifts according to changed Te_L
deg
Compressor capacity can increase
Compressor capacity
cannot increase
Compressor capacity decreases
= 2.0 + Te_L
Te_L (deg)
-9
-8
Interval of "1"
-1
0
1
9
15.0
12.0
A area
B area
C area
0
Max. required level
Lower temperature of B area
= 5.0 + Te_U
CODE: 40
Setting No
-9
-8
-1
0 (factory preset mode)
1
9
A area shifts according to changed Te_H
1 - 7
2WAY SYSTEM
Control Functions-Outdoor Unit
10.0
7.0
5.0
2.0
15
30
Te_U (deg)
-9
-8
Interval of "1"
-1
0
1
9
1