3.2

Mounting

The FX
-J1939 may be installed in a control cabinet with a 35 mm wide DIN46277 DIN rail mounting or M4
3U
screw direct mounting.
3.2.1

DIN rail mounting

The product may be mounted on a 35 mm wide DIN46277 (DIN rail).
1
Fit the upper edge (A in the figure to the right) of the DIN
rail mounting groove onto the DIN rail.
2
Push the product onto the DIN rail.
• An interval space of 1 to 2 mm (0.04" to 0.08") between each unit is necessary.
3
Connect the extension cable.
Connect the extension cable (B in the figure to the right) to
the main unit, I/O extension unit/block or special function
unit/block on the left side of the product.
For further information of the extension cable connection
procedure, refer to the respective product PLC manual.
Refer to MELSEC iQ-F FX5U User's Manual (Hardware)
Refer to MELSEC iQ-F FX5UC User's Manual (Hardware)
• Example of installation on DIN rail
- In the case of the FX
FX
Series main unit
DIN rail
- In the case of the FX
FX
3GC
main unit
DIN rail
Refer to FX
3G
Refer to FX
3GC
Refer to FX
3U
Refer to FX
3UC
/FX
PLC
3G
3U
1 to 2mm
(0.04" to 0.08")
/FX
3G
3U
FX
-J1939
3U
/FX
PLC
3GC
3UC
1 to 2mm
(0.04" to 0.08")
/FX
3UC
FX
-J1939
Series
3U
FX
-CNV-IF or
2NC
FX
-1PS-5V
3UC
Hardware Edition
Hardware Edition
Hardware Edition
Hardware Edition
1 to 2mm
(0.04" to 0.08")
Other
extension
equipment
1 to 2mm
(0.04" to 0.08")
Other
extension
equipment
3 Installation
3.2 Mounting
1
A
B
25
1
2
3
4