Download Print this page

Calibration Steps - Cub Cadet Ultima ZT1 42E Calibration

Throttle position sensor (tps) calibration
Hide thumbs Also See for Ultima ZT1 42E:

Advertisement

IMPORTANT:
The Brake must be released. DO NOT touch the brake pedal during any of the calibration procedures.
NOTE: If during the calibration procedures, an error code shows up on the screen. Start the calibration
procedures over beginning at Step 1 after removing the key.

Calibration Steps:

1. Insert the key into key slot.
2. Make sure both lap bars are in the "OUTWARD"
position as shown in Figure 1.
3. Simultaneously press and hold the ECO
the HEADLIGHT
until the screen displays F N R as shown in Figure 2,
then release the ECO
buttons.
NOTE: If the VCM will not accept calibration inputs,
retry Steps 1 through 3. If the VCM still will not
accept calibration inputs, contact your local
Cub Cadet Service Dealer.
4. Leave the right lap bar in the "OUTWARD"
position and move the left lap bar to the inward
"NEUTRAL" position as shown in Figure 3.
Instruction Sheet
and
buttons for 7 seconds or
and HEADLIGHT
INSTRUCTION SHEET
Lap Bars In The
"OUTWARD"
Position
Right Lap Bar "OUTWARD" Position
Left Lap Bar Inward
"NEUTRAL" Position