2.16.1 Primary UNI-3 Motor Protection Logic

The Primary UNI-3 DC Bus Over-Voltage signal is connected to the controller's PWM
group A fault inputs. The three Primary UNI-3 Phase Over-Current signals are connected
to the device's PWM group A's fault inputs, i.e., FAULTA1, FAULTA2 and FAULTA3.
Figure 2-13
contains the diagram of the Over-Voltage and one phase of the Phase
Over-Current circuit for the UNI-3 interface. The FAULTA1 input can be sourced from
the Phase A Over-Current circuit or the DC Bus Over-Current circuit. Jumper JG15
provides the selection; see
DC BUS CURRENT SENSE
I_sense_DCB
PHASE A CURRENT SENSE
PHA_IS
Table 2-11. FAULTA1 Source Selection Jumper
MOTOROLA
Freescale Semiconductor, Inc.
and
Figure 2-12
+5.0V
+5.0V
+
+5.0V
+5.0V
+
Figure 2-12. FAULTA1 Selection Circuit
JG15
1–2
Phase A Over-Current Sense input
2–3
DC Bus Over-Current Sense input
Technical Summary
For More Information On This Product,
Go to: www.freescale.com
Table
2-11.
+3.3V
LM393
+3.3V
LM393
Comment
Motor Protection Logic
JG15
3
2
FAULTA1
1
2-17