Nokia Customer Care
Cell Power Detector
The following tables illustrate the measurements required for troubleshooting the cell
power detector.
Mode
Local
PA Gain
Tx ADC
Step
RF/IF
GIO
GIO
pdm
12
13
324
L
L
142
L
L
17
L
L
-48
L
L
-48
H
L
-95
H
L
-95
H
H
-146
H
H
-178
H
H
-214
H
H
-252
H
H
-290
H
H
-316
H
H
-328
H
H
-351
H
H
none
Issue 1 07/2004
Table 9: Cell Power Setup
Tx
Rx
On
On
Input Chnn
Tx Freq
384
836.52
Table 10: Cell Power Measurements: Cell, Channel 384
Conn
RF Pout
Pout at
Detector
-50
-86.3
-25
-63
0
-41
6
-30
7
-29
11
-26
13.2
-23.5
17
-21.5
19
-19
21
-17
23
-15
25
-12
26
-11.5
26.5
-11
27.5
-10
dBm
dBm/
30kHz
©2004 Nokia Corporation
Band
Chnn
CELL
384
Rx Freq
881.52
Power Detector
Test
Det
Test
Point
Out
Point
Right
2
Left
R814
C807
2
1.998
1.967
1.957
1.93
1.9
1.86
1.812
1.745
1.667
1.547
1.485
1.44
1.36
VDC
Company Confidential
2112 (RH-57)
Troubleshooting - RF
Rho
On
Comments
Det=Detector
mA
Po=Power
235
CELL band and
detector
coupling is about
22 dB
235
235
250
268
286
435
486
550
630
730
860
950
1000
1095
dBm only refers
to total power
measured
Page 17