Mitsubishi Electric 800 Series Instruction Manual page 19

Hide thumbs Also See for 800 Series:

Advertisement

Setting
Pr.
Name
range
Pre-charge change
0 to 100%,
1132
increment amount
9999
Second pre-charge
0 to 100%,
1133
change increment
9999
amount
Second PID display
1136
0 to 500, 9999 9999

bias coefficient
Second PID display
1137
0 to 300%

bias analog value
Second PID display gain
1138
0 to 500, 9999 9999

coefficient
Second PID display
1139
0 to 300%

gain analog value
Second PID set point/
1140
deviation input
1 to 5
selection
Second PID measured
1 to 5, 101 to
1141
value input selection
105
Second PID unit
1142
0 to 43, 9999
selection
Second PID upper limit 0 to 100%,
1143
9999
Second PID lower limit 0 to 100%,
1144
9999
Second PID deviation
0.0 to 100.0%,
1145
limit
9999
Second PID signal
1146
0 to 7, 10 to 17 0
operation selection
Second output
0 to 3600s,
1147
interruption detection
9999
time
1148
Parameter for manufacturer setting. Do not set.
Second output
1149
interruption cancel level 900 to 1100% 1000%
1150
to
User parameters 1 to 50 0 to 65535
1199
PID gain tuning timeout
1211
1 to 9999s
time
Step manipulated
1212
900 to 1100% 1000%
amount
Step response sampling
1213
0.01 to 600s
cycle
Timeout time after the
1214
1 to 9999s
maximum slope
Limit cycle output upper
1215
900 to 1100% 1100%
limit
Limit cycle output lower
1216
900 to 1100% 1000%
limit
1217
Limit cycle hysteresis
0.1 to 10%
0, 100 to 102,
111, 112, 121,
1218
PID gain tuning setting
122, 200 to
202, 211, 212,
221, 222
PID gain tuning start/
(0), 1, 8, (9,
1219
status
90 to 96)
1300 to
1343,
Communication option parameters
1350 to
1359
Detection time for PID
1361
0 to 900s
output hold
1362
PID output hold range
0 to 50%, 9999 9999
0 to 360s,
1363
PID priming time
9999
Stirring time during
1364
0 to 3600s
sleep
1365
Stirring interval time
0 to 1000h
0 to 100%,
1366
Sleep boost level
9999
Sleep boost waiting
1367
0 to 360s
time
Output interruption
1368
0 to 360s
cancel time
Check valve closing
0 to 120Hz,
1369
completion frequency
9999
Detection time for PID
1370
0 to 900s
limiting operation
PID upper/lower limit
1371
0 to 50%, 9999 9999
pre-warning level range
PID measured value
1372
control set point change
0 to 50%
amount
PID measured value
1373
control set point change
0 to 100%
rate
Auxiliary pressure
1374
pump operation starting
900 to 1100% 1000%
level
Auxiliary pressure
1375
pump operation
900 to 1100% 1000%
stopping level
Auxiliary motor
0 to 100%,
1376
stopping level
9999
Initial
Pr.
Name
value
PID input pressure
9999
1377
selection
PID input pressure
1378
9999
warning level
PID input pressure fault
1379
level
PID input pressure
20%
1380
warning set point
change amount
PID input pressure fault
1381
operation selection
100%
Starting times lower 4
1410
digits
2
Starting times upper 4
1411
digits
Motor induced voltage
3
1412
constant (phi f)
exponent
9999
Second motor induced
1413
voltage constant (phi f)
9999
exponent
9999
PID multistage set point
1460
1
9999
PID multistage set point
1461
2
PID multistage set point
1462
3
PID multistage set point
1s
1463
4
PID multistage set point
1464
5
PID multistage set point
1465
6
PID multistage set point
0
1466
7
Number of cleaning
1469
100s
times monitor
Number of cleaning
1470
times setting
Cleaning trigger
1471
1s
selection
Cleaning reverse
1472
10s
rotation frequency
Cleaning reverse
1473
rotation operation time 0 to 3600s
Cleaning forward
1474
rotation frequency
Cleaning forward
1%
1475
rotation operation time
1476
Cleaning stop time
0
Cleaning acceleration
1477
time
Cleaning deceleration
1478
0
time
1479
Cleaning time trigger
Load characteristics
1480
measurement mode
5s
Load characteristics
1481
load reference 1
Load characteristics
1482
load reference 2
9999
Load characteristics
1483
load reference 3
15s
Load characteristics
1484
load reference 4
0h
Load characteristics
1485
load reference 5
9999
Load characteristics
1486
maximum frequency
0s
Load characteristics
1487
minimum frequency
0s
Upper limit warning
1488
detection width
9999
Lower limit warning
1489
detection width
0s
Upper limit fault
1490
detection width
Lower limit fault
1491
detection width
Load status detection
5%
signal delay time / load
1492
reference measurement
waiting time
0%

For FR-F860-00680

For FR-F860-01080 or higher

The setting value "60" is only available for Pr.178, and
"61" is only for Pr.179.

The setting values "92, 93, 192, 193" are only available
for Pr.190 to Pr.194.

These are the simple mode parameters when the FR-
LU08 is installed. (Initially set to the extended mode.)

The setting is available when the PLC function is
enabled.
9999
Setting
Initial
range
value
1 to 3, 9999
9999
0 to 100%
20%
0 to 100%,
9999
9999
0 to 100%
5%
0, 1
0
0 to 9999
0
0 to 9999
0
0 to 2, 9999
9999
0 to 2, 9999
9999
9999
9999
9999
0 to 100%,
9999
9999
9999
9999
9999
0 to 255
0
0 to 255
0
0 to 15
0
0 to 590Hz
30Hz
5s
0 to 590Hz,
9999
9999
0 to 3600s,
9999
9999
0 to 3600s
5s
0 to 3600s,
9999
9999
0 to 3600s,
9999
9999
0 to 6000hr
0
0, 1, (2, 3, 4, 5,
81, 82, 83, 84,
0
85)
0 to 400%,
9999
8888, 9999
0 to 400%,
9999
8888, 9999
0 to 400%,
9999
8888, 9999
0 to 400%,
9999
8888, 9999
0 to 400%,
9999
8888, 9999
0 to 590Hz
60Hz
0 to 590Hz
6Hz
0 to 400%,
20%
9999
0 to 400%,
20%
9999
0 to 400%,
9999
9999
0 to 400%,
9999
9999
0 to 60s
1s
INVERTER FUNCTION SETTING
Parameter list
19