After completion of the test
10.3.2
Remove all the short-circuited cables for the test and return the disconnected cables as they were according to the
following procedure.
● Reconnect the ground cables and connectors on the PC board as they were.
● Return the dust cover, top panel, right panel, and left panel as they were.
● Connect the input power cable to the input terminal and return the terminal cover.
● Connect the input power cable to the power box switch.
Maintenance and inspection
If power is ON without removing the jumper bar for test,
devices may be damaged or burnt out.
Unless cables removed for test are returned, the unit may not
operate or may malfunction.