GE IC3645SH7R354D1 Installation And Operation Manual page 17

Separately excited (sx) transistorized motor controllers for neighborhood electric vehicle application
Table of Contents

Advertisement

DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
The accelerator pedal is depressed with
-06
no direction selected.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Traction
Accelerator pedal is depressed before closing
forward or reverse directional switch.
Controller
•=
Defective directional switch
•=
Open circuit between directional switch(es)
and 12V positive or between directional
switch(es) and P4 or P5.
•=
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Accelerator voltage input is too high on
-08
power up after initial key switch
closure.
MEMORY RECALL
NO
SYMPTOM
Control will not operate
Circuits valid
for
POSSIBLE CAUSE
Traction
Accelerator input is mis-adjusted or
Controller
defective.
•=Input voltage at P7 should be less than
1.24 volts. Adjust or replace accelerator
unit to insure that the voltage at P7 is
less than 1.24 volts before depressing
pedal.
Disconnect wire from P7. Check for short
circuit from wire to P15. Resistance should
be greater than 3.5K ohms.
Open circuit at P8 or open potentiometer
wiper at P7 – verify continuity of wiring at
both points.
CORRECTIVE ACTIONS
Status code will disappear when
directional switch is closed or when
accelerator pedal is released.
Check forward or reverse switch to insure
closure when direction is selected.
Check all control wires and connections
shown in trouble shooting diagram.
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when the
accelerator voltage, at P7>1.5V, and no direction is
selected (P4 and P5 are both less than 7.2V)
TROUBLE-SHOOTING DIAGRAM
KEY SWITCH *
DIRECTIONAL
SWITCH *
P1
P2 P3
+12V
P15 P14
P16
CAUSE OF STATUS INDICATION
This status code will be displayed when the
accelerator input voltage at P7 >1.24V and either the
battery plug or key switch is opened and closed.
TROUBLE-SHOOTING DIAGRAM
KEY SWITCH *
DIRECTIONAL
SWITCH *
P1
P2 P3
PLUG (23 PIN)
+12V
P15 P14
P16
Page 17
*
L
P4
P5
P21 P11 P10
PLUG (23 PIN)
P7 P9
P13 P8 P6
*
L
P4
P5
P21 P11 P10
P7 P9
P13 P8 P6