Yes, the Glow-worm Ultimate 3 Series boiler can be set to hot water only. The manual indicates that the boiler has different operating modes, including a "Hot water only" mode.
Contents Contents Care and maintenance ....13 Maintenance ........ 13 Safety ..........3 Caring for the product ....13 Action-related warnings ....3 Checking the condensate drain Intended use ........3 pipework and tundish....13 General safety information..... 4 Decommissioning...... 13 Notes on the documentation ..
Safety 1 ral heating installations and for 1 Safety hot water generation. 1.1 Action-related warnings Intended use includes the fol- Classification of action-re- lowing: lated warnings – observance of the operating The action-related warnings instructions included for the are classified in accordance product and any other system with the severity of the pos- components...
1 Safety ▶ Do not use any electrical 1.3 General safety switches, mains plugs, door- information bells, telephones or other 1.3.1 Installation by skilled communication systems in tradesmen only the building. The installation, inspection, ▶ If it is safe to do so, close the maintenance and repair of the emergency control valve or product, as well as the gas ratio...
Page 5
Safety 1 – The product itself flue gas may escape into the room air. – to the gas, air, water and electricity supplies ▶ In order to operate the – to the entire flue gas install- product, ensure that the con- ation densate siphon is always full.
1 Safety lead to corrosion on the product 2 Notes on the and in the air/flue pipe. documentation ▶ Ensure that the supply of 2.1 Observing other applicable combustion air is always free documents of fluorine, chlorine, sulphur, ▶ You must observe all operating instruc- dust, etc.
(1) and in the short operating 3.2 Benchmark instructions (2) (→ Page 7). Glow-worm is a licensed member of the 3.4 Information on the Benchmark Scheme. Benchmark places responsibilities on both identification plate manufacturers and installers.
3 Product description 3.6 Description of the display Information Meaning on the identi- fication plate Type: Xx3(x) Approved flue gas connec- tions Maximum water pressure in heating mode Maximum water pressure in hot water handling mode V/Hz Electric connection Max. electrical power con- Operating in- Display showing sumption...
Operation 4 3.8 Timer 4.1.2 Starting up the product You can control the heating mode using the timer. Position for Functionality the selection switch Heating mode permanently switched off Heating mode intervals in ▶ Press the (2) button. accordance with the timer ◁...
4 Operation 2. Slowly open the filling cock, as shown Note to you by the competent person. If the heating flow temperature 3. Fill with water until the required filling is shown in the display, press pressure is reached. and hold the buttons 4.
Operation 4 ◁ The actual heating flow temperature 4.6.1 Switching the warm start is set automatically by the boiler. function on and off Applicability: Combination unit, Available warm 4.8 Product settings start function for hot water Note ▶ Hold the buttons down simultan- The sequence in which the avail- eously for more than 3 seconds.
5 Troubleshooting 4.10 Switching the product to 4.11.2 Frost protection for the standby mode system ▶ Press the button for less than three Note seconds. Ensure that the product's power ◁ and gas supply are working cor- Once the requirement currently in rectly.
Care and maintenance 6 7 Decommissioning 5.2 Fault codes in the display Fault codes have priority over all other dis- 7.1 Temporarily decommissioning plays. If several faults occur at the same the product time, the corresponding codes are dis- ▶ Temporarily decommission the product played alternately for two seconds each.
9.2 Customer service For contact details for our customer ser- vice department, you can write to the ad- dress that is provided on the back page, or you can visit www.glow-worm.co.uk. Operating instructions Ultimate 3 0020239565_01...
Appendix Appendix A Operator level – overview Setting level Values Unit Increment, select Default set- ting Min. Max. Heating installation Pressure in the heating in- Current value stallation ℃ Heating flow temperature Current value Preset in the system Hot water generation Hot water temperature Current value ℃...
Page 16
Appendix Fault Cause Measure Product does not There is air in the heating installation. Purging the radiators start up: If the problem occurs again: In- form the competent person – No hot water After three successive failed ignition Press the button.
Need help?
Do you have a question about the Ultimate 3 Series and is the answer not in the manual?
Questions and answers
Can I just put my boiler on hot water only, as I have a choice on my remote for heating - hot water
Yes, the Glow-worm Ultimate 3 Series boiler can be set to hot water only. The manual indicates that the boiler has different operating modes, including a "Hot water only" mode.
This answer is automatically generated