5. COOL AIR FAN
The heater may also be used as a cool air fan, as follows:
5.1.
Remove the gas supply hose and plug the heater into the mains electrical power supply.
5.2.
Switch on the fan. The unit will now blow out cool air only.
6.
MAINTENANCE
 WARNING! Before commencing service or maintenance disconnect the unit from the electrical power and the gas supply. Use authorised parts
only.
Unauthorised parts may be dangerous and will invalidate the warranty.
6.1.
Check the gas supply hose condition and change if necessary.
6.2.
Check the starting electrode gap (fig. 8).
6.3.
Check the ignition unit, safety thermostat, and thermocouple condition
and ensure that they are clean.
Caution: Wear safety goggles to perform this operation.
6.4.
Clean inside the heater unit and the fan blade with compressed air.
7. TROUBLESHOOTING
PROBLEM
The fan motor does not work
The ignitor does not spark
no gas flow to the burner
The burner starts, but it stops as
the gas valve is released.
The heater stops during operation
8.
DECLARATION OF CONFORMITY
Declaration of Conformity
Propane Heaters
LP35, LP70, LP80, LP100, LP125, LP200 & LP300
2006/95/EC Low Voltage Directive
2004/108/EC EMC Directive
93/68/EEC CE Marking Directive
Gas Appliances (Safety) Regulations 1992
2006/42/EC Machinery Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this equipment.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
POSSIBLE CAUSE
1. There is no electrical supply.
2. The motor has locked.
1. Electrode has the wrong gap.
2. Faulty connection.
1. The cylinder gas tap is closed.
2. The cylinder is empty.
3. Gas leaks from the supply.
1. The thermocouple is not warm enough.
2. The safety override has activated
because the fan does not work.
1. Excessive gas supply.
2. Insufficient air flow.
3. Insufficient gas due to ice formation
on the cylinder.
We, the sole importer into the UK, declare that the products listed here are in conformity with the following standards and directives.
The construction files for these products are held by the Manufacturer and may be inspected, by a
national authority, upon request to Jack Sealey Ltd.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
fig. 8
SOLUTION
1. Check mains power supply, wire, plug, fuse.
2. Unlock the motor with appropriate tool.
1. Check and reset the electrode to the correct position (fig. 7).
2. Check and connect correctly the ignitor and the electrode.
1. open the gas tap.
2. Replace the cylinder.
3. Remove and clean the nozzle, check for leaks by using a
foamy soap only DO NOT USE FLAME to find leak.
1. Repeat the starting operation keeping the button pushed for
a longer time
2. See above "Motor does not work"
1. Check the pressure reducer, and replace if necessary.
2. Check that the motor is working correctly.
3. Check and if necessary use a larger gas cylinder or multiple
cylinders connected parallel.
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
01284 757500
01284 703534
LP35.V5, LP70, LP80.V4, LP100.V2, LP145.V2, LP200.V3 & LP300.V4 - 2 - 210108
5mm
21st January 2008
www.sealey.co.uk
W e b
sales@sealey.co.uk
email

Advertisement

loading

This manual is also suitable for:

Lp70Lp80.v4Lp100.v2Lp145.v2Lp200.v3Lp300.v4