5.1.3 Switches and rear side
When removing or replacing a fuse:
To prevent an accident caused by an electric shock, make sure to turn the power
switch off before such removal or replacement
Front panel
1
2
1
REMOTE CONTROLLER outlet:
Connect the plug of the remote controller (sepa-
rately sold).
2
TORCH SWITCH outlet:
Connect the plug of the torch switch.
3
+ terminal (for base metal) (Fingertip joint):
For TIG or SPOT welding.
Connect the fingertip joint of the base metal cable.
After inserting the plug, turn clockwise until the con-
nector is fastened.
GAS OUTLET: (Screw size: 9/16-18UNF)
4
For TIG or SPOT welding.
Connect the joint of the gas hose from the welding
torch.
5
- terminal (for torch) (Fingertip joint):
For TIG or SPOT welding.
Connect the fingertip joint of the TIG torch cable.
After inserting the plug, turn clockwise until the con-
nector is fastened.
OMCTT5621E18
WARNING
3
4
5
Names and Functions
Rear panel
8
9
10
6
Gas inlet: (Screw size: 9/16-18UNF)
Connect the shield gas for welding from the gas
regulator completely.
* Air incorporation may affect the welding result.
7
Wiring port (Covered with grommet):
To insert wires, make a cut in the grommet.
8
D-SUB connector (for robot):
Input power terminal:]
9
10
Cooling fan air-outlet:
This is the cooling fan air-outlet to cool this prod-
uct.
Do not leave any obstacles near this outlet.