Monitoring The Status; Status Monitor Under Normal Conditions - Toshiba TOSVERT VF-AS1 Instruction Manual

The new generation high-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

8.2 Monitoring the status

8.2.1 Status monitor under normal conditions

In this mode, you can monitor the operation status of the inverter.
To monitor the inverter when it is normally running, press the    key
on the LED display.
Setting procedure (EX.: operation at 60 Hz)
Commun
ication
No.
*1
-
FE01
FE01
*2
-
*3
-
*4
-
*5
-
*6
-
8
*7
-
-
*8
*9
-
FE06
FE50
FE51
FE07
FE52
FE08
FE73
(Continued overleaf)
Key
Item displayed
operated
Standard monitor
mode
Setting monitor
MODE
mode
Status monitor
mode
MODE
(Rotating direction)
Operation frequency
command
Load current
DC voltage
Output voltage
Torque
Regenerative
braking resistance
overload factor
(PBrOL data)
Inverter overload
factor
(OL1 data)
Motor overload
factor
Input terminal
information 1
Input terminal
information 2
Input terminal
information 3
Output terminal
information 1
Output terminal
information 2
CPU1 version
CPU2 version
twice
MODE
LED
display
The operation frequency is displayed (during operation).

(When standard monitor display selection  is set
to 0 [Operation frequency])
The first basic parameter "History function ()" is

displayed.
The rotating direction is displayed. (:Forward run,

:Reverse run)
The operation frequency command value is displayed.

(When F711=1, operation frequency command)
The inverter output current (load current) is displayed.

(When F712=2, current display)
The Inverter DC voltage (default setting:unit %) is

displayed.(When F713=3, DC voltage) [Note 3]
The inverter output voltage (default setting:unit %) is

displayed.(When F714=4, output voltage)
The torque is displayed.

(When F715=8, torque)
The regenerative braking resistance overload factor is
displayed.

(When F716=16, regenerative braking resistance
overload factor)
The inverter overload factor is displayed.

(When F717=15, inverter overload factor)
The peak output current (default setting:unit %) is
displayed.

(When F718=14, Motor overload factor)
The ON/OFF status of each of the control signal input
       
terminals (F, R, RES, ST, S1, S2, S3, RR/S4) is
displayed in bits.
The ON/OFF status of each of the optional control signal
      
input terminals (L1, L2, L3, L4) is displayed in bits.
The ON/OFF status of each of the optional control signal
      
input terminals (L5, L6, L7, L8) is displayed in bits.
The ON/OFF status of each of the control signal output
  
terminals (OUT1, OUT2, FL) is displayed in bits.
The ON/OFF status of each of the control signal input
       
terminals (OUT3, OUT4, R1, OUT5, OUT6, R2, R3, R4)
is displayed in bits.
The version of the CPU1 is displayed.

The version of the CPU2 is displayed.

H-2
E6581301
and the current status is indicated
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents