Error Codes Indication; Display - Mitsubishi Electric ecodan PUHZ-W50VHA2 User Manual

Monobloc air source heat pumps
Hide thumbs Also See for ecodan PUHZ-W50VHA2:
Table of Contents

Advertisement

Error Codes Indication

If the ON lamp and display 10
are both blinking: This means
that the Ecodan is out of order
and operation has been stopped
(and cannot resume). Take note
of the indicated unit number and
error code, then switch off the
power to the Ecodan and call
your installer.
If only the display 10 is blinking (while the ON lamp remains lit): Operation is continuing, but there may be a problem with the
system. In this case, you should note down the error code and then call your installer for advice.
If you have entered contact number to be called in the event of a problem, push the button J to display it on the screen.

Display

The PAR-W21MAA has many different functions that control the performance of the Ecodan. Below are the symbols and
displays used for each function.
Waiting for start-up
Operational Mode
Heating
Heating ECO
Hot water
Anti-freeze
Stand by (Hot adjust)
Defrost
Not in use button
Check (Error)
Test run
Self check
Change language
Language selection
Display change
Temperature display °C/°F setting
Throughout the system set-up buttons on the controller are referenced by letters and displays by numbers ; this key can be found on page 41
SYSTEM SET -UP
If
you
have
entered
contact number to be
called in the event of a
problem,
the
screen
displays this number.
(You can set this up
under Function Selection
of remote controller).
Fig. 4.8
Water temperature display
Function selection
Operation function limit setting
Mode Skip setting
Mode skip
Temperature range limit setting
Temperature
range limit setting
mode
Mode selection
Use of clock setting
Setting the day of the week and time
Table 3.1
Loading
48
Alternating Display
When the Check Button is pressed:
Heating
Heating ECO
Hot water
Anti-freeze
Cooling
Hot water
Anti-freeze
Cooling
Fig. 4.7
Fig. 4.9
49

Hide quick links:

Advertisement

Table of Contents
loading