Mitsubishi Electric EHSD-MED Service Manual page 82

Hydrobox
Table of Contents

Advertisement

Engineers Forms
Commissioning/Field settings record sheet (continued from the previous page)
Main remote controller screen
Setting Initial settings Language
°C/°F
Summer time
Temp. display
Time display
Room sensor settings for Zone1
Room sensor settings for Zone2 *2
Room RC zone select *2
Service menu Thermistor adjustment
Auxiliary settings
Pump speed
Heat source setting
Heat pump setting
Operation
settings
OCH712C
THW1
THW2
THW5B
THW6
THW7
THW8
THW9
THW10
THWB1
Economy settings
for pump.
Electric heater
(Heating)
Electric heater
(DHW) *4
Mixing valve control Running (10
Flow sensor *12
Analog output
DHW
Heating/Cooling
Heat pump flow rate range
Quiet mode
Heating
Flow temp.range
operation
*14
Room temp.
control
*15
Heat pump thermo
diff.adjust
Freeze stat function *16
Simultaneous operation (DHW/
Heating)
Cold weather function
Boiler operation
Parameters
EN/FR/DE/SV/ES/IT/DA/NL/FI/NO/PT/BG/PL/CZ/RU/
TR/SL
°C/°F
On/Off
Room/DHW tank/Room&DHW tank /Off
hh:mm/hh:mm AM/AM hh:mm
TH1/Main RC/Room RC1-8/"Time/Zone"
TH1/Main RC/Room RC1-8/"Time/Zone"
Zone1/Zone2
−10°C
to
+10°C
−10°C
+10°C
to
−10°C
to
+10°C
−10°C
+10°C
to
−10°C
to
+10°C
−10°C
to
+10°C
−10°C
+10°C
to
−10°C
to
+10°C
−10°C
+10°C
to
On/Off *11
Delay (3
to
60 min)
Space heating: On (used)/Off (not used)
Electric heater delay timer (5
to
180 min)
Booster heater
DHW: On (used)/Off (not used)
Immersion heater
DHW: On (used)/Off (not used)
Electric heater delay timer (15
to
30 min)
240 sec)
to
Interval (1
to
30 min)
Minimum (0
100 L/min)
to
Maximum (0
100 L/min)
to
Interval (1
to
30 min)
Priority (Normal/High)
Pump speed (1
to
5)
Pump speed (1
5)
to
Standard/Heater/Boiler/Hybrid *13
Minimum (0
to
100 L/min)
Maximum (0
100 L/min)
to
Day (Mon
to
Sun)
Time
Quiet level (Normal/ Level1/ Level2)
Min.temp.(20
to
45°C)
Max.temp.(35
60°C)
to
Mode(Normal/Fast)
Interval(10
60 min)
to
On/Off *11
Lower limit (−9
−1°C)
to
Upper limit (+3
to
+5°C)
Outdoor ambient temp. (3
20°C) / **
to
On/Off *11
Outdoor ambient temp. (−30
to
+10°C) *8
On/Off *11
Outdoor ambient temp. (−30
to
−10°C) *8
Hybrid settings
Outdoor ambient temp.
(−30
+10°C) *8
to
Priority mode
(Ambient/Cost/CO 2 ) *17
Outdoor ambient temp. rise
(+1
to
+5 °C)
Intelligent
Energy
Electricity (0.001
settings
price
Boiler (0.001
*18
CO
Electricity
2
emis-
(0.001
to
sion
Boiler
(0.001
Heat
Heat pump capacity
source
(1
40 kW)
to
Boiler efficiency
(25
to
150%)
Booster heater 1 capacity
(0
30 kW)
to
Booster heater 2 capacity
(0
30 kW)
to
82
Default setting
EN
°C
Off
Off
hh:mm
TH1
TH1
Zone1
0°C
0°C
0°C
0°C
0°C
0°C
0°C
0°C
0°C
On
10 min
On
30 min
On
On
15 min
120 sec
2 min
5 L/min
100 L/min
5 min
Normal
5
5
Standard
5 L/min
100 L/min
0:00 - 23:45
Normal
30°C
50°C
Normal
10 min
On
−5°C
5°C
5°C
Off
−15°C
Off
−15°C
−15°C
Ambient
+3 °C
999 */kWh) 0.5 */kWh
to
to
999 */kWh)
0.5 */kWh
0.5 kg -CO
/
2
999 kg -CO
/kWh)
kWh
2
0.5 kg -CO
/
2
to
999 kg -CO
/kWh)
kWh
2
11.2 kW
80%
2 kW
4 kW
(Continued to next page.)
Field
Notes
setting