DISASSEMBLY PROCEDURE
4. How to swing the control box to the front
(1) Remove the front panel. (Refer to Procedure 1.)
(2) Remove the 2 screws from the control box bracket (R) and
the 2 screws from the control box bracket (L). (Photo 4-1
and 4-2)
(3) Disengage the control box bracket (R) from the right-hand
side panel and pull the control box. At this point, lifting
slightly and pulling the control box will swing the control
box to the front. (Photo 4-3)
Note: Disconnect the field wiring as necessary.
Photo 4-2
Earth cable
Screws
Cable strap
Note: The photo shown is of the ERSE-YM9ED.UK model.
OCH712C
Photo 4-1
Screws
Note: The photo shown is of the EHSD-MED.UK model.
Photo 4-3
Side panel
Screws
Bracket
(R)
62
PHOTOS/ FIGURES
Earth cable
Cable strap
Control box
Swing
Side panel
Screws
Bracket
(R)