No.
Working STEP
Attaching
the
4
plug shell
Attaching the
5
insulation tube
supplied
Appendix. Processing the ends of the coaxial cable
Description of work
Insert it in the plug shell after soldering.
(10)
Check to ascertain that the connection areas on the central semi-
conductor and the terminal are not bent when inserting them.
Good
Gasket
Washer
Insert the gasket, the washer and the nut in that order
(11)
after the cable has been inserted into the plug shell.
Fastening nut
Washer
Clamp
Take care not to damage the end of the terminal when
inserting it into the plug shell.
Check to ascertain that the end of the terminal has not
(12)
been pushed to the very back of the plug shell.
Cover the BNC connector with the insulation tube.
(13)
Insulated cable connector tube
If the BNC connector in use is not the recommended model
and has a larger diameter preventing it from being inserted
into the insulation tube, cut the tube as shown below. Secure
the insulation tube in place from the top with insulation tape
to prevent it from falling of.
Appendix-6
No good
Plug shell
Gasket
Terminal
Plug shell
Terminal
Plug shell
Cut in a straight line.
Remark