PARAMETER
Parameter
Name
826
Torque setting filter 1
Torque detection filter
827
1
Model speed control
828
gain
830
Speed control P gain 2
Speed control integral
831
time 2
832
Speed setting filter 2
Speed detection filter
*1
833
2
Torque control P gain
834
2
Torque control inte-
835
gral time 2
836
Torque setting filter 2
Torque detection filter
837
2
Torque bias
*1
840
selection
*1
841
Torque bias 1
*1
Torque bias 2
842
*1
Torque bias 3
843
*1
844
Torque bias filter 0 to 5s, 9999
Torque bias oper-
*1
845
ation time
Torque bias bal-
*1
ance compensa-
846
tion
Fall-time torque
*1
847
bias terminal 1
bias
Fall-time torque
*1
bias terminal 1
848
gain
Analog input off-
849
set adjustment
Brake operation
850
selection
Speed deviation
853
time
854
Excitation ratio
Terminal 4 func-
858
tion assignment
859
Torque current
Second motor
860
torque current
Notch filter time
862
constant
863
Notch filter depth 0, 1, 2, 3
864
Torque detection 0 to 400%
Low speed
865
detection
Torque monitoring
866
reference
867
AM output filter
Terminal 1 function
868
assignment
869
Current output filter
Speed detection
870
hysteresis
*1
Setting can be made only when the FR-A7AP/FR-A7AL is mounted.
*2
Parameters cannot be copied from FR-A720 or FR-A740.
23
Setting Range
Initial Value
0 to 5s, 9999
9999
0 to 0.1s
0s
0 to 1000%
60%
0 to 1000%,
9999
9999
0 to 20s, 9999
9999
0 to 5s, 9999
9999
0 to 0.1s, 9999
9999
0 to 200%, 9999
9999
0 to 500ms,
9999
9999
0 to 5s, 9999
9999
0 to 0.1s, 9999
9999
0 to 3, 9999
9999
600 to 1400%,
9999
9999
9999
0 to 5s, 9999
9999
0 to 10V, 9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
9999
0 to 200%
100%
0, 1, 2
0
0 to 100s
1s
0 to 100%
100%
0, 1, 4, 9999
0
9999
0 to 3600A,
9999
9999
0 to 60
0
0
150%
0 to 400Hz
1.5Hz
0 to 400%
150%
0 to 5s
0.01s
0 to 6, 9999
0
0 to 5s
0.02s
0 to 5Hz
0Hz
Parameter
Name
Input phase loss
872
protection
selection
873
Speed limit
874
OLT level setting 0 to 200%
875
Fault definition
Speed feed for-
ward control/
877
model adaptive
speed control
selection
Speed feed for-
878
ward filter
Speed feed for-
879
ward torque limit
880
Load inertia ratio 0 to 200 times
Speed feed for-
881
ward gain
Regeneration
882
avoidance opera-
tion selection
Regeneration
883
avoidance opera-
tion level
Regeneration
avoidance at
884
deceleration
detection
sensitivity
Regeneration
avoidance com-
885
pensation fre-
quency limit
value
Regeneration
886
avoidance volt-
age gain
888
Free parameter 1
889
Free parameter 2
Cumulative
power monitor
891
digit shifted
times
892
Load factor
Energy saving
monitor refer-
893
ence (motor
capacity)
Control selec-
tion during com-
894
mercial power-
supply operation
Power saving
895
rate reference
value
896
Power unit cost
Power saving
897
monitor average
time
Power saving
898
cumulative moni-
tor clear
Operation time
899
rate (estimated
value)
C0
CA terminal
(900)
calibration
C1
AM terminal
(901)
calibration
Setting Range
Initial Value
0, 1
1
0 to 120Hz
20Hz
150%
0, 1
0
0, 1, 2
0
0 to 1s
0s
0 to 400%
150%
7
0 to 1000%
0%
0, 1, 2
0
300 to 1200V
1080V DC
0 to 5
0
0 to 30Hz, 9999
6Hz
0 to 200%
100%
9999
0 to 9999
9999
0 to 4, 9999
9999
30 to 150%
100%
Inverter
0.1 to 3600kW
rated
capacity
0, 1, 2, 3
0
0, 1, 9999
9999
0 to 500, 9999
9999
0, 1 to 1000h,
9999
9999
0, 1, 10, 9999
9999
0 to 100%, 9999
9999