Installing the OAU 2A
1
Installation at a 1+0 Site
Installation procedure
1
Install an OAU 2A on a wall or pole.
• Determine whether to install an OAU 2A on a wall or pole based on actual
conditions.
• If an OAU 2A needs to be installed on a tower, it is recommended that you
install it at the foot of the tower to facilitate maintenance.
2
Install a ground cable.
Install the device-side ground cable before you climb up the tower.
3
Install an IF cable.
Connect the IF ports of the OAU 2A and XMC ODU using an IF cable.
• The IF2 port is enabled for the device by default. You are advised to
preferentially use the IF2 port at a 1+0 site.
• For the method of making and laying out an IF cable, see the RTN XMC
ODU Quick Installation Guide.
Do not remove or insert an IF cable connector from or to the OAU 2A with
power on. Otherwise, human injuries may be caused.
4
Install an outdoor fiber or network cable.
• Connect an outdoor fiber or network cable to a port in the maintenance
compartment.
• Lay out the outdoor fiber or network cable.
• Attach a yellow label to the fiber or network cable, and write a number on
the label according to the plan.
Install a DC power cable.
5
• Connect a DC power cable to the DC power port in the maintenance
compartment.
• Lay out the DC power cable.
• Select ground points for the DC power cable, and install ground clips.
• Attach a matte white label to the DC power cable.
Before installing a cable, bind the cable section that links the cable connector to
the pole. This will protect the cable connector from damage. Ensure that the
length of cable running from the binding point to the OAU 2A is sufficient to
attach the cable connector to a service port on the OAU 2A.
6
Waterproof ground clips and IF cable connectors.
For the method of installing an antenna,
follow the antenna installation guide
delivered with the antenna.
For the method of installing an
XMC ODU, see the RTN XMC
ODU Quick Installation Guide.
1
GE3(o)
PWR
IF1
6
2
Connected to a
power supply
device
To a NodeB
5
DC
power
cable
Grounded using
DC
a ground clip
power
cable
6
8
6
NOTE
3
The GE1(e) or GE2(e) port can be used
to transmit/receive electrical services,
and the GE3(o) or COMBO port can be
used to transmit/receive optical services.
In this example, the GE3(o) port is used.
4
Commissioning procedure
Power on the OAU 2A.
1
Use the Web LCT to configure
2
NE data.
3
Align antennas.
You can use an alignment scope to
align antennas. For details about how
to install an alignment scope, see the
appendix.
Check the installation.