10.7

EMC filter (recommended)

It is recommended that one of the following filters be used to comply with EN EMC directive. Some EMC filters have a large
leakage current.
When connecting one or more converter units to one EMC filter, satisfy the following conditions:
• Rated input of EMC filter [V] ≥ Rated input voltage of the converter units [V]
• Rated current of EMC filter [A] ≥ Rated input current of the converter units [A]
Application
EMC filter
environment
Model
IEC/EN 61800-3
FSB-20-355
*1
Category C2, C3
FSB-30-355
FSB-40-355
FSB-80-355
FSB-100-355
FSB-150-355
IEC/EN 61800-3
HF3030C-SZL
*1
Category C3
HF3060C-SZL
HF3100C-SZL
HF3150C-SZL
*1 Category C2: intended for use in the first environment (residential environment) only when installed by professional personnel or for use
in the second environment (commercial, light industry and industrial environments)
Category C3: intended for use in the second environment (commercial, light industry and industrial environments)
Rated current
Rated voltage
[A]
[VAC]
20
500
30
40
80
100
150
30
500
60
100
150
Operating
Mass [kg]
temperature
[°C]
-40 to 85
1.8
3.3
6.3
8.8
-20 to 50
1.3
2.1
5.8
9.0