Download Print this page
Sealey PC1950 Instructions Manual
Sealey PC1950 Instructions Manual

Sealey PC1950 Instructions Manual

1450psi

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used
according to these instructions and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO
MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
1. SAFETY INSTRUCTIONS
1.1
ELECTRICAL SAFETY
p WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A
Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current
Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by
an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
The Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
1.1.1
electrician, using a Portable Appliance Tester (PAT), at least once a year.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
1.1.2
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.
and use a Portable Appliance Tester.
1.1.4
Ensure that cables are always protected against short circuit and overload.
1.1.5
Regularly inspect power supply cables and plugs for wear or damage and check all
connections to ensure that none is loose.
1.1.6
Important: Ensure that the voltage marked on the appliance matches the power supply
to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7
DO NOT pull or carry the appliance by the power cable.
DO NOT pull the plug from the socket by the cable.
1.1.8
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty
1.1.9
item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK
3 pin plug is damaged, cut the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly
connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.
Double insulated products, which are always marked with this symbol
To rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.
1.1.10 Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure
that a 30 amp supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your
electrician.
1.1.11 If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use
of 2.5mm² section cable.
1.2
GENERAL SAFETY
WARNING! Water and electricity are dangerous partners. Be extremely cautious and always be aware that this device uses an
p
electric motor. Always plug into a RCD (See electrical safety above). Unplug from mains before changing accessories or servicing.
WARNING! DO NOT USE the washer if any part of the unit, gun, nozzle, detergent tank, hose or cables is damaged. Replace or
p
repair using genuine parts only. Unauthorised parts may be dangerous and will invalidate your warranty. Always check connections
are correctly secured and not cracked or damaged in any way before using the machine.
WARNING! Use washer on a flat, levelled surface, in an upright position. Failure to do so will invalidate your warranty.
p
NEVER lay the washer down during use.
Ensue you comply with all local water supply regulations. Power washers may only be connected to mains drinking water supply if a
4
back flow preventer valve is installed in the supply hose, or at the tap outlet.
The supply hose must must be reinforced, and have an internal diameter of 1/2”. The water supply must be at least equal to the
4
cleaner capacity. The water temperature must NOT exceed 122°F (50°C). The water supply pressure must NOT exceed 6 bar.
Always be aware of the hazards that may occur during use. Study all applications and limitations of the washer before use.
4
Use where air can freely circulate around the washer to avoid the machine overheating.
4
Keep the washer in good condition. Use an authorised service agent to service the unit.
4
Wear adequate protective clothing, goggles and anti-slip rubber soled footwear.
4
Position the washer as near to the water supply as possible.
4
WARNING! Ensure all persons and animals keep at a minimum distance of 16 yards (15mtr) from the washer when in use.
p
WARNING! The pressure washer must only be used with clean water. Unfiltered water or corrosive chemicals must not be used as
p
these will damage the cleaner.
Ensure the nozzle is aimed correctly at the work surface before switching on the machine.
4
INSTRUCTIONS FOR:
PRESSURE WASHER
MODEL:
Blue
Neutral
Wire
FUSE RATING 13 AMP
, are fitted with live (brown) and neutral (blue) wires only.
1450PSI
PC1950
Yellow & Green
Earth Wire
Brown
Live
Wire
Cable
Restraint
PC1950 - 1 - 190105

Advertisement

loading

Summary of Contents for Sealey PC1950

  • Page 1 Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
  • Page 2 Unpack the product and check contents against the list below. Also check that the machine has an identification plate or label. If label or parts are damaged or missing contact your supplier immediately. ON/OFF Switch Water inlet (at rear) Lance High pressure hose connector Detergent dispenser High pressure hose PC1950 - 1 - 190105...
  • Page 3: Connecting The Water Supply

    (fig 4) ensuring that the connector is tight. Turn on the water supply. ASSEMBLING THE LANCE OR DETERGENT DISPENSER Push the lance/dispenser onto the gun (fig 5) and turn through 90 until it clicks into place. PC1950 - 1 - 190105...
  • Page 4: Operation

    If the motor continues to cut out contact your authorised service agent. d) If storing the washer for a long period during winter, operate the washer with a non-corrosive, non-toxic anti-freeze before storage. Store detergents according to instructions on the container label. PC1950 - 1 - 190105...
  • Page 5: Troubleshooting Guide

    Injector clogged. Clean injector. Jet is ineffective,ragged or unsteady. Nozzle clogged. Clean nozzle. Fuse blows in plug. Back pressure build up of water Depress trigger before switching on the machine. causes machine to draw high amperage. PC1950 - 1 - 190105...
  • Page 6: Regular Maintenance

    89/392/EEC Machine Directive of Sealey Power Products. 73/23/EEC Low Voltage Directive 89/336/EEC EMC Directive 2000/14/EC Sound Pressure Directive 93/68/EEC Marking Directive Sole UK Distributor, Sealey Group, Bury St. Edmunds, Suffolk. 01284 757500 01284 703534 www.sealey.co.uk sales@sealey.co.uk email PC1950 - 1 - 190105...