CS351 | 3609929B45/2014-09
Check whether the Compact System and
the computer unit are connected to each
other.
1. Open the Windows Start menu of the
computer unit, enter "CMD" in the
search box, and push the <ENTER>
key. This opens a user prompt.
2. Enter the ping command with the IP
address of the Compact System, which
is "ping 192.168.1.7" in the example.
Fig. 33:
"ping" command output
The computer and the Compact System are
connected if the "Packets" line of the
screen displays "Sent = 4" and "Received
= 4".
Bosch Rexroth AG
8

Operation

CAUTION
Disconnection of plug connectors
that are carrying voltage!
Damage to the Compact System
Always switch the system off at the
main switch and then disconnect the
power supply connection cable. Wait
until the discharging time (at least 90
seconds) has elapsed.
CAUTION
Contamination of the Compact Sys-
tem!
Injuries and damage to property
Only operate the Compact System
with the front cover closed.
CAUTION
Hot surfaces!
Injuries
The metal surfaces of the housing may
have a temperature of up to 70 °C du-
ring operation.